Operating instruction
Precision/compact balances and platform scales
Table of contents:
1MODE - MENUE.......................................................................................................3
2Technical data.........................................................................................................5
2.1 KERN 572..............................................................................................................................................5
2.2 KERN 573..............................................................................................................................................8
2.3 KERN KB/KBJ ......................................................................................................................................9
2.4 KERN DS.............................................................................................................................................13
2.5 KERN FCB ..........................................................................................................................................18
2.6 KERN FKB ..........................................................................................................................................19
3Fundamental information (general).....................................................................22
3.1 Intended use.......................................................................................................................................22
3.2 Inappropriate use...............................................................................................................................22
3.3 Guarantee...........................................................................................................................................22
3.4 Monitoring the test substances .......................................................................................................22
4Fundamental safety information..........................................................................23
4.1 Observe the information in the operating instructions .................................................................23
4.2 Staff training.......................................................................................................................................23
5Transport and storage..........................................................................................23
5.1 Acceptance check..............................................................................................................................23
5.2 Packaging...........................................................................................................................................23
6Unpacking, installation and commissioning......................................................24
6.1 Place of installation, place of use....................................................................................................24
6.2 Unpacking ..........................................................................................................................................24
6.2.1 Installation............................................................................................................................................24
6.3 Mains supply......................................................................................................................................24
6.4 Battery operation FKB.......................................................................................................................25
6.5 Connecting peripheral equipment ...................................................................................................25
6.6 Initial start-up.....................................................................................................................................25
6.7 Adjustment.........................................................................................................................................25
6.8 Adjusting (go to 7.2.6).......................................................................................................................26
6.8.1 Adjusting for verification (KERN 573; FKB-M; KB-NM; FCB-M; DS-M)...............................................26
6.9 Verification .........................................................................................................................................27
7Operation...............................................................................................................28
7.1 Display control panel ........................................................................................................................28
7.2 Operation............................................................................................................................................29
7.3 Display background illumination.....................................................................................................35
7.4 Interface RS 232 C.............................................................................................................................35
7.5 RS 232 C Data output via interface RS 232 C .................................................................................36
7.5.1 Description of the data transfer............................................................................................................37
7.5.2 Numerator............................................................................................................................................37
7.6 Printer .................................................................................................................................................37
7.7 Underfloor weighing..........................................................................................................................38
8Maintenance, upkeep, disposal ...........................................................................39
8.1 Cleaning..............................................................................................................................................39
8.2 Maintenance, upkeep ........................................................................................................................39
8.3 Disposal..............................................................................................................................................39
9Troubleshooting....................................................................................................40
10 Declaration of conformity.....................................................................................41

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
3
1 MODE - MENUE
Models 572/573/KB/DS/FKB/FCB:
Important!
The modified settings - as well as the adjustment - must be stored when switching-off, via the
ON/OFF button.

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
4
Models KBJ:
Important!
The modified settings - as well as the adjustment - must be stored when switching-off, via the
ON/OFF button.

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
5
2 Technical data
2.1 KERN 572
KERN
572-30
572-31
572-32
572-33
Readability (d)
0.001 g
0.001 g
0.001 g
0.01 g
Weighing range (max)
240 g
300 g
420 g
1600 g
Taring range (subtractive)
240 g
300 g
420 g
1600 g
Reproducibility
0.001 g
0.002 g
0.002 g
0.01g
Linearity
± 0.003 g
± 0.005 g
± 0.005 g
± 0.03 g
Smallest piece weight
0.001 g
0.001 g
0.001 g
0.01 g
Adjustment points
50/100/
200/240 g
50/100/
200/300 g
100/200/
300/400 g
0.5/1.0/
1.5/1.6 kg
Recommended adjusting
weight F1 (not supplied)
200 g
200 g +100 g
200 g + 200 g
1 kg + 500 g
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
4 hours
2 hours
Housing (B x D x H) mm
180 x 310 x 90
Vibration filter
yes
Weighing plate stainless
steel mm
Ø 106
Ø 106
Ø 106
Ø 150
Units
see menu
Weight kg (net)
2.3
2.3
2.3
2.3
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
6
KERN
572-35
572-37
572-39
572-43
Readability (d)
0.01 g
0.01 g
0.01 g
0.1 g
Weighing range (max)
2400 g
3000 g
4200 g
10000 g
Taring range (subtractive)
2400 g
3000 g
4200 g
10000 g
Reproducibility
0.01 g
0.02 g
0.02 g
0.1g
Linearity
± 0.03 g
± 0.05 g
± 0.05 g
± 0.3 g
Smallest piece weight
0.01 g
0.01 g
0.01 g
0.1 g
Adjustment points
0.5/1.0/
2.0/2.4 kg
1.0/1.5/
2.0/3.0 kg
1.0/2.0/
3.0/4.0 kg
2/5/10 kg
Recommended adjusting
weight F1 (not supplied)
2 kg
2 kg + 1 kg
2 kg + 2 kg
10 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
4 hours
2 hours
Housing (B x D x H) mm
180 x 310 x 90
Vibration filter
yes
Weighing plate stainless
steel mm
Ø 150
Ø 150
Ø 150
160 x 200
Units
see menu
Weight kg (net)
2.3
2.3
2.3
2.7
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
7
KERN
572-45
572-49
572-55
572-57
Readability (d)
0.05 g
0.1 g
0.05 g
0.1 g
Weighing range (max)
12000 g
16000 g
20000 g
24000 g
Taring range (subtractive)
12000 g
16000 g
20000 g
24000 g
Reproducibility
0.05 g
0.1 g
0.1 g
0.1g
Linearity
± 0.15 g
± 0.3 g
± 0.25 g
± 0.3 g
Smallest piece weight
0.05 g
0.1 g
0.05 g
0.1 g
Adjustment points
2/5/10/12 kg
5/10/15/16 kg
5/10/15/20 kg
5/10/15/20/24 kg
Recommended adjusting
weight F1 (not supplied)
10 kg
10 kg + 5 kg
20 kg
20 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
2 hours
2 hours
Housing (B x D x H) mm
180 x 310 x 90
Vibration filter
yes
Weighing plate stainless
steel mm
160 x 200
160 x 200
160 x 200
160 x 200
Units
see menu
Weight kg (net)
2.7
2.7
2.7
2.7
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
8
2.2 KERN 573
KERN
573-34NM
573-46NM
Accuracy class
II
II
Readability (d)
0.01 g
0.1 g
Verification value (e)
0.1 g
1 g
Weighing range (max)
650 g
6500 g
Minimum load (Min)
0.5 g
5 g
Taring range (subtractive)
650 g
6500 g
Reproducibility
0.01 g
0.1 g
Linearity
± 0.03 g
± 0.3 g
Smallest piece weight
0.01 g
0.1 g
Adjustment points
200g/500g/600g
2/5/6 kg
Recommended adjusting
weight F1 (not supplied)
500 g + 100 g
5 kg + 1 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 30 °C
Warm-up time
2 hours
2 hours
Housing (B x D x H) mm
180 x 310 x 90
Vibration filter
yes
Weighing plate stainless
steel mm
Ø 150
160 x 200
Units
g, kg
g, kg
Weight kg (net)
2.3
2.7
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
9
2.3 KERN KB/KBJ
KERN
KB 120-3N
KB 240-3N
KB 360-3N
Readability (d)
0.001 g
0.001 g
0.001 g
Weighing range (max)
120 g
240 g
360 g
Taring range (subtractive)
120 g
240 g
360 g
Reproducibility
0.001 g
0.001 g
0.002 g
Linearity
± 0.003 g
± 0.003 g
± 0.005 g
Smallest piece weight
0.001 g
0.001 g
0.001 g
Adjustment points
20/50/100/120 g
100/150/
200/240 g
100/200/
300/360 g
Recommended adjusting
weight F1 (not supplied)
100 g
200 g
200 g + 100 g
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
4 hours
Housing (B x D x H) mm
167 x 250 x 85
Vibration filter
yes
Weighing plate stainless
steel mm
Ø 81
Ø 81
Ø 81
Units
see menu
Weight kg (net)
1
1
1
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
10
KERN
KB 1200-2N
KB 2000-2N
KB 2400-2N
KB 3600-2N
Readability (d)
0.01 g
0.01 g
0.01 g
0.01 g
Weighing range (max)
1 200 g
2 000 g
2 400 g
3 600 g
Taring range (subtractive)
1 200 g
2 000 g
2 400 g
3 600 g
Reproducibility
0.01 g
0.01 g
0.01 g
0.02 g
Linearity
± 0.03 g
± 0.03 g
± 0.03 g
± 0.05 g
Smallest piece weight
0.01 g
0.01 g
0.01 g
0.01 g
Adjustment points
0.2/0.5/1.0/1.2 kg
0.5/1.0/1.5/2.0 kg
1.0/1.5/2.0/2.4 kg
1.0/2.0/3.0/3.6 kg
Recommended adjusting
weight F1 (not supplied)
1 000 g
2 000 g
2 000 g
2 kg + 1 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
2 hours
4 hours
Housing (B x D x H) mm
167 x 250 x 85
Vibration filter
yes
Weighing plate stainless
steel mm
130 x 130
130 x 130
130 x 130
130 x 130
Units
see menu
Weight kg (net)
1.5
1.5
1.5
1.5
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
11
KERN
KB
10000-1N
KB
10k0.05N
Readability (d)
0.1 g
0.05 g
Weighing range (max)
10 000 g
10 000 g
Taring range (subtractive)
10 000 g
10 000 g
Reproducibility
0.1 g
0.05 g
Linearity
0.3 g
0.15 g
Smallest piece weight
0.1 g
0.05 g
Adjustment points
2/5/10 kg
2/5/10 kg
Recommended adjusting
weight F1 (not supplied)
10 kg
10 kg
Stabilization time (typical)
3 sec.
3 sec.
Permitted environmental tem-
perature
+10 °C ... + 40 °C
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
Housing (B x D x H) mm
167 x 250 x 85
167 x 250 x 85
Weighing plate stainless steel
mm
150 x 170
150 x 170
Units
see menu
see menu
Vibration filter
yes
yes
Weight kg (net)
1.7
1.7
Data interface
yes (RS232)
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
12
KERN
KB
650-2NM
KB
6500-1NM
KBJ
650-2NM
Accuracy class
II
II
II
Readability (d)
0.01 g
0.1 g
0.01 g
Verification value (e)
0.1 g
1 g
0.1 g
Weighing range (max)
650 g
6 500 g
650 g
Minimum load (Min)
0.5 g
5 g
0.5 g
Taring range (subtractive)
650 g
6 500 g
650 g
Reproducibility
0.01 g
0.1 g
0.01 g
Linearity
± 0.03 g
± 0.3 g
±0.03 g
Smallest piece weight
0.01 g
0.1 g
0.01 g
Adjustment points
200/500/600 g
2/5/6 kg
-
Recommended adjusting
weight F1 (not supplied)
600 g
6.0 kg
Int. Adjustment
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 30 °C
Warm-up time
2 hours
2 hours
2 hours
Housing (B x D x H) mm
167 x 250 x 85
Vibration filter
yes
Weighing plate stainless
steel mm
130 x 130
150 x 170
130 x 130
Units
g, kg, ct
Weight kg (net)
1.5
1.7
2.1
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
13
2.4 KERN DS
KERN
DS
3K0.01S
DS
5K0.05S
DS
8K0.05
DS
10K0.1S
Readability (d)
0.01 g
0.05 g
0.05 g
0,1 g
Weighing range (max)
3 000 g
5 000 g
8 000 g
10.000 g
Taring range (subtractive)
3 000 g
5 000 g
8 000 g
10.000 g
Reproducibility
0.02 g
0.05 g
0.05 g
0.1 g
Linearity
± 0.05 g
± 0.15 g
± 0.15 g
±0.3 g
Smallest piece weight
0.01 g
0.05 g
0.05 g
0.1 g
Adjustment points
1/2/3 kg
2/5/10 kg
2/4/5/7/8 kg
2/5/10 kg
Recommended adjusting
weight F1 (not supplied)
3 kg
10 kg
5 kg + 2 kg
10 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
2 hours
2 hours
Housing (B x D x H) mm
228 x 228 x 70
228 x 228 x 70
315 x 305 x 70
228 x 228 x 70
Vibration filter
Weighing plate stainless
steel mm
228 x 228
228 x 228
315 x 305
228 x 228
Units
see menu
see menu
see menu
see menu
Weight kg (net)
5.5
5.5
7.5
5,5
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
14
KERN
DS
16K0.1
DS
20K0.1
DS
30K0.1
Readability (d)
0.1 g
0.1 g
0.1 g
Weighing range (max)
16 000 g
20 000 g
30 000 g
Taring range (subtractive)
16 000 g
20 000 g
30 000 g
Reproducibility
0.1 g
0.1 g
0.2 g
Linearity
± 0.3 g
± 0.3 g
± 0.5 g
Smallest piece weight
0.1 g
0.1 g
0.1 g
Adjustment points
5/10/15/16 kg
5/10/15/20 kg
10/15/20/30 kg
Recommended adjusting
weight F1 (not supplied)
10 kg + 5 kg
20kg
20 kg + 10 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
2 hours
Housing (B x D x H) mm
315 x 305 x 70
Vibration filter
yes
Weighing plate stainless
steel mm
315 x 305
315 x 305
315 x 305
Units
see menu
see menu
see menu
Weight kg (net)
7.5
7.5
7.5
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
15
KERN
DS
36K0.2
DS
30K0.1L
DS
36K0.2L
DS
60K0,2
Readability (d)
0.2 g
0.1 g
0.2 g
0.2 g
Weighing range (max)
36 000 g
30 000 g
36 000 g
60 000 g
Taring range (subtractive)
36 000 g
30 000 g
36 000 g
60 000 g
Reproducibility
0.2 g
0.2 g
0.2 g
0.4 g
Linearity
± 0.6 g
± 0.5 g
± 0.6 g
± 1.0 g
Smallest piece weight
0.2 g
0.1 g
0.2 g
0.2 g
Adjustment points
10/15/20/
30/36 kg
10/15/20/
30 kg
10/15/20/
30/36 kg
20/30/50/60 kg
Recommended adjusting
weight F1 (not supplied)
20 kg + 10 kg
20 kg + 10 kg
20 kg + 10 kg
50 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
2 hours
2 hours
Housing (B x D x H) mm
315 x 305 x 70
450 x 350 x 115
Vibration filter
yes
Weighing plate stainless
steel mm
315 x 305
450 x 350
Units
see menu
see menu
see menu
see menu
Weight kg (net)
7.5
9.5
9.5
9.5
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
16
KERN
DS
65K0.5
DS
100K0.5
DS
150K1
Readability (d)
0,5 g
0,5 g
1 g
Weighing range (max)
65 000 g
100 000 g
150 000 g
Taring range (subtractive)
65 000 g
100 000 g
150 000 g
Reproducibility
0,0 g
0,5 g
1 g
Linearity
± 1,5 g
± 1,5 g
± 3 g
Smallest piece weight
0,5 g
0,5 g
1 g
Adjustment points
20/30/50/60 kg
20/50/100 kg
50/100/150 kg
Recommended adjusting
weight F1 (not supplied)
50 kg
50 kg + 50 kg
3 x 50 kg
3 x 50 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
2 hours
Housing (B x D x H) mm
450 x 350 x 115
Vibration filter
yes
Weighing plate stainless
steel mm
450 x 350
Units
see menu
see menu
see menu
Weight kg (net)
9.5
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
17
KERN
DS
65K1M
Accuracy class
II
Readability (d)
1 g
Verification value (e)
10 g
Weighing range (max)
65 000 g
Minimum load (Min)
50 g
Taring range (subtractive)
65 000 g
Reproducibility
1 g
Linearity
± 2 g
Smallest piece weight
1 g
Adjustment points
20/30/50/
60 kg
Recommended adjusting
weight F1 (not supplied)
50 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 30 °C
Warm-up time
2 hours
Housing (B x D x H) mm
450 x 350 x 115
Vibration filter
Weighing plate stainless
steel mm
450 x 350
Units
see menu
Weight kg (net)
9.5
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
18
2.5 KERN FCB
KERN
FCB
6K0.02B
FCB
12K0.05B
FCB
12K0.1B
FCB
24K0.1B
FCB
24K0.2B
Readability (d)
0.02 g
0.05 g
0.1 g
0.1 g
0.2 g
Weighing range (max)
6 000 g
12 000 g
12 000 g
24 000 g
24 000 g
Taring range (subtrac-
tive)
6 000 g
12 000 g
12 000 g
24 000 g
24 000 g
Reproducibility
0.04 g
0.05 g
0.1 g
0.1 g
0.2 g
Linearity ±
0.1 g
0.15 g
0.3 g
0.3 g
0.6 g
Smallest piece weight
0.02 g
0.05 g
0.1 g
0.1 g
0.2 g
Adjustment points
2/5/6 kg
2/5/10/12 kg
2/5/10/12 kg
5/10/15/
20/24 kg
5/10/15/
20/24 kg
Recom. adjustment
weight F1
(not added)
5 kg
10 kg
10 kg
20 kg
20 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typi-
cal)
3 sec.
Permitted environmen-
tal temperature
+ 10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
2 hours
2 hours
2 hours
Vibration filter
yes
Housing
(B x D x H) mm
270 x 345 x 106
270 x 345 x 106
270 x 345 x 106
270 x 345 x 106
270 x 345 x 106
Weighing plate, stain-
less steel
253x228
253x228
253x228
253x228
253x228
Units
see menu
Vibration filter
yes
Weight kg (net)
3.3
3.3
3.3
3.3
3.3
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
19
2.6 KERN FKB
KERN
FKB
6K0.02
FKB
8K0.05
FKB
16K0.05
FKB
16K0.1
Readability (d)
0.02 g
0.05 g
0.05 g
0.1 g
Weighing range (max)
6 000 g
8 000 g
16 000 g
16 000 g
Taring range (subtractive)
6 000 g
8 000 g
16 000 g
16 000 g
Reproducibility
0.04 g
0.05 g
0.1 g
0.1g
Linearity
± 0.1 g
± 0.15 g
± 0.25 g
± 0.3 g
Smallest piece weight
0.02 g
0.05 g
0.05 g
0.1 g
Adjustment points
2/4/5/6 kg
2/4/5/7/8 kg
5/10/15/16 kg
5/10/15/16 kg
Recommended adjusting
weight F1 (not supplied)
5 kg
5 kg + 2 kg
10 kg + 5 kg
10 kg + 5 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
2 hours
2 hours
2 hours
2 hours
Housing (B x D x H) mm
350 x 390 x 120
Vibration filter
yes
Weighing plate stainless
steel mm
340 x 240
340 x 240
340 x 240
340 x 240
Units
see menu
see menu
see menu
see menu
Weight kg (net)
6.5
6.5
6.5
6.5
Data interface
yes (RS232)

572/573/KB/DS/FKB/FCB/KBJ-BA-e-1370
20
KERN
FKB
36K0.1
FKB
36K0.2
FKB
65K0.2
FKB
65K0.5
Readability (d)
0.1 g
0.2 g
0.2 g
0.5 g
Weighing range (max)
36 000 g
36 000 g
65 000 g
65 000 g
Taring range (subtractive)
36 000 g
36 000 g
65 000 g
65 000 g
Reproducibility
0.2 g
0.2 g
0.4 g
0. g
Linearity
± 0.5 g
± 0.6 g
± 1.0 g
± 1.5 g
Smallest piece weight
0.1 g
0.2 g
0.2 g
0.5 g
Adjustment points
10/20/30/36 kg
10/20/30/36 kg
20/30/50/60 kg
20/30/50/60 kg
Recommended adjusting
weight F1 (not supplied)
20 kg + 10 kg
20 kg + 10 kg
50kg
50kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
Permitted environmental
temperature
+10 °C ... + 40 °C
Warm-up time
4 hours
2 hours
4 hours
2 hours
Housing (B x D x H) mm
350 x 390 x 120
Vibration filter
yes
Weighing plate stainless
steel mm
340 x 240
340 x 240
340 x 240
340 x 240
Units
see menu
see menu
see menu
see menu
Weight kg (net)
6.5
6.5
6.5
6.5
Data interface
yes (RS232)
Other manuals for 572
4
This manual suits for next models
60
Table of contents
Other KERN Scale manuals

KERN
KERN CXP 150K10 User manual

KERN
KERN MPS_M User manual

KERN
KERN CH50K500 User manual

KERN
KERN MPN Series User manual

KERN
KERN KERN MBB-M series User manual

KERN
KERN ITS User manual

KERN
KERN FFN-N Series User manual

KERN
KERN MH Series User manual

KERN
KERN KERN MPB User manual

KERN
KERN RIB Series User manual