Table of Contents
1Technical Data__________________________________________________ 4
2Basic Information (General)_______________________________________ 5
2.1 Proper use_______________________________________________________ 5
2.2 Improper Use ____________________________________________________ 5
2.3 Warranty ________________________________________________________ 5
2.4 Monitoring of Test Resources _______________________________________ 6
3Basic Safety Precautions_________________________________________ 7
3.1 Pay attention to the instructions in the Operation Manual________________ 7
3.2 Personnel training ________________________________________________ 7
4Transportation & Storage_________________________________________ 7
4.1 Testing upon acceptance __________________________________________ 7
4.2 Packaging _______________________________________________________ 7
5Unpacking, Setup and Commissioning _____________________________ 8
5.1 Installation Site, Location of Use ____________________________________ 8
5.2 Unpacking _______________________________________________________ 9
5.2.1 Balance assembly and installation _________________________________________ 9
5.2.2 Scope of delivery _____________________________________________________ 12
5.2.3 Assembly instructions for models with wall fixing device _______________________ 12
5.3 Mains connection ________________________________________________ 13
5.4 Battery operation (insertion and removal) ____________________________ 13
5.5 Initial Commissioning ____________________________________________ 13
5.6 Adjustment _____________________________________________________ 13
5.6.1 Procedure when adjusting ______________________________________________ 13
5.7 Menu overview __________________________________________________ 16
6Operation_____________________________________________________ 18
6.1 Controls 4-button terminal ________________________________________ 18
6.1.1 Display _____________________________________________________________ 18
MPB / MXS -BA-e-0810
2

6.1.2 Keyboard overview____________________________________________________ 19
7Using the balance______________________________________________ 20
7.1 Weighing _______________________________________________________ 20
7.2 Taring__________________________________________________________ 20
7.3 Hold function (Standstill function) __________________________________ 21
7.4 Calculation of the Body Mass Index _________________________________ 21
7.4.1 Classification of BMI values _____________________________________________ 22
8Error message_________________________________________________ 23
9Service, maintenance, disposal___________________________________ 23
9.1 Cleaning _______________________________________________________ 23
9.2 Service, maintenance_____________________________________________ 23
9.3 Disposal________________________________________________________ 23
10 Instant help _________________________________________________ 24
MPB / MXS -BA-e-0810 3

1 Technical Data
KERN MPB300K100 / P MXS300K100
Readability (d) 100 g
Weighing range (max) 300 kg 300kg
Recommended adjust-
ment weight, (Class) 200 kg
(M2) 200 kg
(M2)
Stabilization time (typical) 2 – 3 sec.
Warm-up time 10 min
Mains adapter 9V / 100 mA
Electric Supply Battery operation 6 x 1.5V, size AA
Service life 170h
Auto Off After 3 min without load change (adjustable)
Operating temperature + 5°C … + 35°C
Storage temperature - 20°C … + 60°C
Humidity of air max. 80 % (not condensing)
Platform (B x D x H )mm 315x300x60 550 x 550x80
Terminal (B x T x H) mm 210 x 110 x 48
Balance ready for opera-
tion
(B x D x H) mm
Without stand: 315x300x60
with stand: 315x440x1010 550 x 550x80
Weight kg (net) Without stand: 4.0
with stand : 5.8 14.0
MPB / MXS -BA-e-0810
4

2 Basic Information (General)
2.1 Proper use
These balance is used to calculate the weight of people in the private sphere.
Utilisation of this balance in the medical field is not permissible.
A person must stand on the weighing plate for the weighing procedure. As soon as a
stable weighing value is reached the weighing value can be read.
When using balance with height measurement, ensure that the top flap is turned
downwards immediately after use in order to avoid risk of injury.
The balance should be checked for correct condition prior to each utilisation by a
person familiar with proper operation of the balance.
2.2 Improper Use
Do not use balance for dynamic weighings. In the event that small quantities are re-
moved or added to the material to be weighed, incorrect weighing results can be dis-
played due to the “stability compensation“ in the balance. (Example: Slowly draining
fluids from a container on the balance. )
Do not leave permanent load on the weighing plate. This may damage the measuring
system.
Impacts and overloading exceeding the stated maximum load (max) of the balance,
minus a possibly existing tare load, must be strictly avoided. This could cause dam-
age to the balance.
Never operate balance in explosive environment. The serial version is not explosion
protected.
The structure of the balance may not be modified. This may lead to incorrect weigh-
ing results, safety-related faults and destruction of the balance.
The balance may only be used according to the described conditions. Other areas of
use must be released by KERN in writing.
2.3 Warranty
Warranty claims shall be voided in case
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
mechanical damage and damage caused by media, liquids
natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
Dropping the balance
MPB / MXS -BA-e-0810 5

2.4 Monitoring of Test Resources
In the framework of quality assurance the measuring-related properties of the bal-
ance and, if applicable, the testing weight, must be checked regularly. The responsi-
ble user must define a suitable interval as well as type and scope of this test. Infor-
mation is available on KERN’s home page (www.kern-sohn.com) with regard to the
monitoring of balance test substances and the test weights required for this. In
KERN’s accredited DKD calibration laboratory test weights and balances may be
calibrated (return to the national standard) fast and at moderate cost.
Using measuring technology to check the accuracy of the measuring device is rec-
ommended for personal balances with body height measurement but is not abso-
lutely essential as the calculation of the human body height is always subject to a
great deal of inaccuracy.
MPB / MXS -BA-e-0810
6

3 Basic Safety Precautions
3.1 Pay attention to the instructions in the Operation Manual
Carefully read this operation manual before setup and commissioning, even if you
are already familiar with KERN balances.
3.2 Personnel training
The appliance may only be operated and maintained by trained personnel.
4 Transportation & Storage
4.1 Testing upon acceptance
When receiving the appliance, please check packaging immediately, and the appli-
ance itself when unpacking for possible visible damage.
4.2 Packaging
Keep all parts of the original packaging in case you need to return the appliance.
Only use original packaging for returning.
Before sending, disconnect all connected cables and loose/movable parts.
Attach possibly existing transport safeguards. Secure all parts e.g. weighing platform,
power pack, stand, operating panel etc. against slipping and damage.
MPB / MXS -BA-e-0810 7

5 Unpacking, Setup and Commissioning
5.1 Installation Site, Location of Use
The balances are designed in a way that reliable weighing results are achieved in
common conditions of use.
You will work accurately and fast, if you select the right location for your balance.
Therefore, observe the following for the installation site:
- Place the balance on a firm, level surface;
- Avoid extreme heat as well as temperature fluctuation caused by installing
next to a radiator or in the direct sunlight;
- Protect the balance against direct draughts due to open windows and doors;
- Avoid jarring during weighing;
- Protect the balance against high humidity, vapors and dust;
- Do not expose the device to extreme dampness for longer periods of time.
Non-permitted condensation (condensation of air humidity on the appliance)
may occur if a cold appliance is taken to a considerably warmer environment.
In this case, acclimatize the disconnected appliance for ca. 2 hours at room
temperature.
- Avoid static charge of the balance and of the person to be weighed.
- Avoid contact with water.
If electro-magnetic fields or static charge occur, or if the power supply is unstable
major deviations on the display (incorrect weighing results) are possible. In that case,
the location must be changed.
MPB / MXS -BA-e-0810
8

5.2 Unpacking
Remove the individual components of the balance or the complete balance from the
packaging with care and install at the intended location. When using the power pack,
ensure that the power cable does not produce a risk of stumbling.
5.2.1 Balance assembly and installation.2.1 Balance assembly and installation
MPB personal balance with wall fixing device:MPB personal balance with wall fixing device:
Scope of delivery:Scope of delivery:
MPB personal balance with stand:
Scope of delivery:
MPB / MXS -BA-e-0810 9

Assembly:
Insert stand into the holder on the platform and secure with the 3 screws. (See illus-
tration below left). Lay cable in the space and secure cover with the 4 screws (See
illustration below right).
MXS adipose balance:
Scope of delivery:
MPB / MXS -BA-e-0810
10

Instructions for attaching an optimum body-height measuring device to the
model MPB with stand
A separately available body-height measuring device can be screwed onto this
model. Follow the operating instructions for the body-height measuring device for this
purpose.
Instructions for attaching an external stand to Model MPB without stand and
Model MXS.
Secure wall fixing device with screws at the top on the aluminium section
Secure circular plate with screws on the aluminium section
Remove the two lateral rubber plugs from the display unit.
Secure the display unit with the two rotary knobs to the fixing device.
Position display unit with the rotary knobs.
Secure cable with cable clips
MPB / MXS -BA-e-0810 11

General instructions for installing the aforementioned balance.
Install the personal balance in the intended location exactly horizontally. Align the
adipose balance horizontally by means of the height-adjustable rubber feet.
When installing or transporting balances with large and heavy platforms (weighing
plate folded upwards), ensure that the balance do not fall over or get damaged.
5.2.2 Scope of delivery
Serial accessories:
•Mains power supply
•Operating Manual
5.2.3 Assembly instructions for models with wall fixing device
(Personal balance, adipose balance )
MPB / MXS -BA-e-0810
12

5.3 Mains connection
Power is supplied via the external mains adapter. The stated voltage value must be
the same as the local voltage. Only KERN original power packs should be used.
5.4 Battery operation (insertion and removal)
On models where the back of the display unit is not directly accessible, remove the
two black rotary knobs from both sides of the display unit in order to open the battery
compartment and remove the display unit from the holder. Remove battery cover
from under the display unit. Insert 6 x 1.5V AA batteries into the holder. Replace bat-
tery cover and screw the display unit back into the holder using the black rotary
knobs.
In order to save the battery, the balance switches automatically off after 3 minutes
without weighing. Further shutdown times can be set in the Menu
(Function "A.OFF"), see chapter 5.7.
If the batteries are run down, "LO" appears in the display. Press [ON/OFF] -key and
replace the batteries immediately.
If the balance is not used for a longer time, take out the batteries and store them
separately. Leaking battery liquid could damage the balance.
5.5 Initial Commissioning
In order to obtain exact results with the electronic balances, your balance must have
reached the operating temperature (see warming up time chap. 1). During this warm-
ing up time the balance must be connected to the power supply (mains, accumulator
or battery) and be switched on.
The accuracy of the balance depends on the local acceleration of gravity.
Strictly observe hints in chapter Adjustment.
5.6 Adjustment
As the acceleration value due to gravity is not the same at every location on earth,
each balance must be coordinated - in compliance with the underlying physical
weighing principle - to the existing acceleration due to gravity at its place of location
(only if the balance has not already been adjusted to the location in the factory). This
adjustment process must be carried out during the initial start-up, after change in lo-
cation and variation of surrounding temperature. To receive accurate measuring val-
ues it is also recommended to adjust the balance periodically in weighing operation.
Use the adjustment weight (See Technical Data) to check and adjust the accuracy of
the balance at any time.
5.6.1 Procedure when adjusting
Observe stable environmental conditions. A warming up time (see chapter 1) is re-
quired for stabilization.
MPB / MXS -BA-e-0810 13

Operation Display
Turn on balance by pressing the [ON/OFF] key
a
z000
Keep [→0←]button depressed for approx. 3 sec until
"SETUP" is displayed followed by "9rAd"
SETUP
9RAD
Press the [ TARE ] button as often as required until
"CAL ib" is displayed
CAL
K
B
Press the [HOLD] button.
CAL O
Press the [TARE] key. ( Zero count mode )
30770
Press the [→0←]button repeatedly until "CAL 0" is
displayed.
CAL O
Press the [HOLD] button.
CAL 5
Press the [TARE] key.
Enter the required size of the adjustment weight (See
Section 1, "Technical Data"): Press the [HOLD] button
to select the item to be changed and press the [TARE]
button to select the numerical value.
200.0
Confirm by pressing the [→0←]button.
0
Place the adjustment weight carefully in the centre of
the weighing plate and a numerical value will appear in
the display. Press the [HOLD] button. The adjustment
process is started.
82077
MPB / MXS -BA-e-0810
14

The balance will automatically return to Weighing
mode upon successful completion of the adjustment
and will display the weight of the adjustment weight.
Take away adjustment weight.
200.0
Turn off balance by pressing the [ON/OFF] key.
MPB / MXS -BA-e-0810 15

5.7 Menu overview
Navigation in the menu:
With the balance switched on, keep the [→0←]button depressed for approx. 3
sec until "SETUP" is displayed followed by "9rAd".
Press the [ TARE ] button as often as necessary until the required function is
displayed.
Press the [HOLD] button to confirm the selected function. The first parameter
will be displayed. Press the [HOLD] button to select the required parameter
and confirm by pressing the [ TARE ] button.
To exit the Menu and save, press the [ TARE ] button as often as required until
"END" is displayed and then confirm by pressing the [HOLD] button. The balance
returns automatically into weighing mode.
Select using the [HOLD] and the [ TARE]-button
x factory setting
MPB / MXS -BA-e-0810
16

Description:
Partition steps, weighing range (max.) and readout (d)
Multi-range balance/ single-range balance selection
Single-range balance
Multi-range balance
Auto Zero Tracking: 0.25d/ 0.5d/ 1d/ 3d/ OFF
Stabilisation range: 0.25d/ 0.5d/ 1d/ 3d/ OFF
Zero range: 2% / 100%
Overload range: 9d / 2%
Adjustment
Auto off: 120 sec/ 180 sec/ 240 sec/ 300 sec/ OFF
Audio signal: ON/OFF
Resetting to factory setting (Default setup)
Exit menu
MPB / MXS -BA-e-0810 17

6 Operation
6.1 Controls 4-button terminal
6.1.1 Display
Max 300 kg d = 0.1 kg
kg
MPB
1
2
345 67
Overview of display
No. Display Description
1 [→0←]Balance zero display: Should the balance not display
exactly zero despite an empty scale pan, press the
[→0←]button. Your balance will be set to zero after a
short standby time.
2 [ο]Stability display:
If the display shows the stability display [ο]the balance
is in a stable status. The [ο]indication disappears if the
condition is unstable.
3 Illuminates in the event of power supply via mains adap-
tor
4 BMI
SCalculated BMI value
5 HOLD
SHold/Save function active
6 NET
SNet weight will be displayed
7 WEIGHT
SCurrent weight value will be displayed
MPB / MXS -BA-e-0810
18

6.1.2 Keyboard overview
Key Description
ON/OFF Turn on/off balance
0
Balance will be reset to 0.0 kg.
Possible up to max. 2 % or 100% of maximum load
(can be selected in the menu)
In BMI Mode: Acceptance of input
HOLD Hold function/Calculation of a stable weight value
BMI Function call-up: Body Mass Index
In BMI Mode: Moving the input point
TARE Tare balance
In BMI Mode: Reducing the input value
MPB / MXS -BA-e-0810 19

7 Using the balance
7.1 Weighing
Turn on balance by pressing the [ON/OFF] key. The balance carry out a seg-
ment test, then the program version is displayed. Your balance is ready to
weigh as soon as the “0.0 kg" display appears.
Information: The [→0←]key can be used to set the balance to zero at any
time.
Place person in the centre of the balance or place baby in the scale pan. Wait
until the standstill display (ο) appears, then read the weighing result.
Note:
If the person is heavier than the weighing range, "Err" (=overload) will appear in the
display.
7.2 Taring
The tare weight of any preloads can be deducted by pressing a button so that the
actual weight of the person is displayed in subsequent weighings.
The balance will display 0 if, for example, a rubber mat has been placed
on the weighing plate.
To start the taring process press the [TARE] key. The weight will now be
saved internally and 0.0 kg will be displayed.
Place the person in the middle of the weighing plate.
Now read the weight from the display.
Information:
The balance is able to only store one taring value at a time.
When the balance is unloaded the saved taring value is displayed with negative sign.
Remove all items from the weighing plate in order to delete the stored tare value and
subsequently press the [TARE] key.
MPB / MXS -BA-e-0810
20
Other manuals for KERN MPB
1
This manual suits for next models
4
Table of contents
Other KERN Scale manuals

KERN
KERN EW-N Series User manual

KERN
KERN PCB Series User manual

KERN
KERN ECB Series User manual

KERN
KERN MPE 200K-1HEM User manual

KERN
KERN MPE 250K100HM User manual

KERN
KERN PES Series User manual

KERN
KERN RFC User manual

KERN
KERN TABP-A02-A User manual

KERN
KERN MWB series User manual

KERN
KERN HFD User manual