
TOS3200
9
SCPI Command Syntax .................................................................................... 110
Parameters........................................................................................................ 112
Command Description in This Manual ............................................................................... 114
IEEE488.2 Common Commands ....................................................................................... 115
Selecting the Operation Mode............................................................................................ 118
Setting the TC Measurement and PCC Measurement....................................................... 118
Setting the Connection Destination of the Measurement Terminal
(TC measurement only)..................................................................................... 118
Setting the Power Line Polarity ......................................................................... 119
Setting the Single Fault Mode ........................................................................... 119
Setting the Lower Reference............................................................................. 120
Setting the Upper Reference............................................................................. 120
Setting the Test Time and Test Wait Time ........................................................ 121
Setting the Measurement Network (TC measurement only) ............................. 123
Setting the Measurement Mode ........................................................................ 123
Setting the Measurement Range....................................................................... 124
Querying the Settings........................................................................................ 124
Saving and Recalling from the Panel Memory .................................................. 125
Executing the Test (Trigger Function) ................................................................................ 126
Saving and Querying the Test Result................................................................................. 130
Querying the Judgment Result (Common to All Tests) ..................................... 130
Saving the Result .............................................................................................. 130
Querying the Result........................................................................................... 131
Deleting the Test Results .................................................................................. 132
Setting the Program Test ................................................................................................... 133
Setting the Meter Mode Measurement ............................................................................... 138
Setting the Measurement Network (Current Measurement Only) ..................... 138
Setting the Measurement Mode ........................................................................ 138
Setting the Measurement Range (Current Measurement Only)........................ 139
Querying the Settings........................................................................................ 139
Querying the Measured Value............................................................................................ 140
Querying the Measured Current Flowing
through Measurement Terminals A and B......................................................... 140
Querying the Measured Voltage
between the Measurement Network Reference Points ..................................... 140
Querying the Measured Voltage
between Measurement Terminals A and B (Voltage Measurement Only) ........ 141
Clearing the Maximum Measured Value ........................................................... 142
Voltage, current, and power of the EUT............................................................ 142
Various Settings ................................................................................................................. 144
Holding the Maximum Measured Current.......................................................... 144
Pass Judgment Hold Time ................................................................................ 144
Converting Measured Current Based on the Specified Line Voltage ................ 144
Setting the Safety Extra Low Voltage (SELV) ................................................... 145
Setting the Buzzer Volume................................................................................ 145
Setting the Screen Brightness........................................................................... 146
Setting the Time ................................................................................................ 146
Turning the Power Line to the EUT On/Off ....................................................... 147
Showing/Hiding Communication Errors............................................................. 147
Releasing the Protection Status........................................................................ 147
Other Settings ................................................................................................... 148
Status Register and Status Report Function ...................................................................... 150
IEEE488.2 Register Model ................................................................................................. 152
Status Byte Register.......................................................................................... 152
Event Status Register........................................................................................ 153
SCPI Register Model.......................................................................................................... 154
OPERation Status Register............................................................................... 154