JetNet 7310G Industrial 8 GbE plus 2 GbE SFP Ethernet Switch
Quick Installation Guide V1.0
The JetNet 7310G is an pure Gigabit Managed Switch with 8 ports Gigabit Ethernet plus IEEE
802.3at PoE/PSE function, and 2 Gigabit SFP for Gigabit Ethernet fiber connection.
The Switch system offers 240W system PoE Power budget with 35W forwarding capability in
each port with high voltage (54V) power input.
The Switch system’s housing is designed with one pieces of heat-sink to dissipate heat when
perform high power PoE for DOM IP Camera, Wireless AP. It also provides excellent heat
dissipation, even working in road-side cabinet, it still can deliver high power to far-end
PoE-PDs. It also adopts comprehensive network feature with brilliant Electro-Magnetic
Susceptibility testing level carried out the ability for the Railway Track –Side surveillance.
Package Check List

JetNet 7310G

DIN Mounting kit

DB-9 to RJ-45 RS-232 Console Cable

Quick Installation Guide
Wiring the Power Inputs & Earth Grounding
1. Insert the positive and negative wires into the V+ and V- contact on the
terminal block connector.
2. Connect the Chassis
Grounding to Earth Ground
system to obtain electromagnetic
immunity to resist lighting,
electro static discharge and
electric fast transient.
3. Tighten the wire-clamp screws to prevent the power wires from being loosened.
Notes: The recommended working voltage is DC 53V. Use the UL Listed LPS Power supply
with output Rating 46~57 VDC, minimum 5A currents.
Installation
You can configure JetNet 7310G via the RS-232 console with the attached console cable. Or
you can remotely manage the switch via network. You can choose Telnet/SSH,
Web/HTTPS management.
Preparation for console management
Attach the RS-232 DB9 connector to your PC’s COM port. Connect the RJ-45 connector to
the console port of the JetNet Switch.
1. Go to Start ► Program ► Accessories ► Communication ► Hyper Terminal
2. Give a name to the new console connection.
3. Choose the COM name and select the correct serial settings. The serial port settings are as
below: Baud Rate:115200/Parity: None/Data Bit: 8/Stop Bit: 1
4. After connected, you will see the Switch login request. Type the username and password
and then you can login. The default username is “admin”, password is “admin”.
5. Follow the manual to configure the software features.
Preparation for Web management
1. Launch the web browser on the PC.
2. Type http://JetNet Managed Switch_IP_Address (The default IP address is 192.168.10.1.),
then press Enter.
3. The login screen will appear next. Type in the user name and password and click “OK”
button. The default user name and password is admin/admin.
4. At the left column of the web management interface are the software features, where ring
column will list the available settings.
5 Years Warranty
Each of Korenix’s product is designed, produced, and tested with high industrial standard.
Korenix warrants that the product(s) shall be free from defects in materials and
workmanship for a period of five (5) years from the date of delivery provided that the
product was properly installed and used.
This warranty is voided if defects, malfunctions or failures of the warranted product are
caused by damage resulting from force measure (such as floods, fire, etc.), other external
forces such as power disturbances, over spec power input, or incorrect cabling; or the
warranted product is misused, abused, or operated, altered and repaired in an unauthorized
or improper way.
Attention! To avoid system damage caused by sparks, please DO NOT plug in power
connector when power is on.
The product is in compliance with Directive 2002/95/EC and 2011/65/EU of the
European Parliament and of the Council of 27 January 2003 on the restriction of the use of
certain hazardous substances in electrical and electronics equipment (RoHS Directives &
RoHS 2.0)
Korenix Customer Service
KorenixCARE is Korenix Technology’s global service center, where our professional staffs
are ready to answer your questions at any time.
Email address of Korenix Global Service Center : [email protected]
Support
Device Management
Mounting the unit
The DIN Rail clip on the rear of JetNet 7310G, and supports 35mm DIN rail.
Interface Introduction
JetNet 7310G supports 8 ports Gigabit Ethernet RJ-45, and 2 ports Gigabit Ethernet SFP
socket for fiber connection.
Wiring the Digital Input
The Digital Input (DI) contacts are in
the bottom. It accepts one external DC
type signal input and can be configured
to send alert message through Ethernet
when the signal is changed. The signal
may trigger and generated by external
power switch, like as door open trigger
switch for control cabinet.
Note: The DI accepts DC type signal and supports isolated input circuit with Digital High
Level input DC 11V~30V and Digital Low Level input DC 0V~10V. Do not apply voltage
higher than the specification; it may cause internal circuit damage or a wrong action of DI.
Connecting the Surge/Lighting protection
The surge protection activate screw located on the rear side that nearby the DIN rail clip.
Always tighten the screw and ensure the surge protection activate
screw is tighten with Earth-Ground well.
Note:
1. Ensure the Surge/Lighting is well connecting with
Chassis Grounding.
2. Remove the Surge/Lighting Screw before perform insulation/
Hi-pot testing.
3. Never install or work on/with the equipment or the cabling
during the period of its lightning activity.
Wiring the Relay Output
The relay output contacts are in the bottom
side. The relay output (DO) is controlled by
the pre-defined operating rules.
To activate relay output function, please
refer to the User’s Manual for more relay
output management information.
Notes: The relay contact only supports
0.5 A current, DC 24V. It is not recommended to apply voltage and current higher than the
specifications.
4
1 2
5 65
7 8
PoE
7
5
8
6
8 GbE/PSE 2 100/1000 SFP
Managed Gigabit PoE Switch
3
1
4
2
9 10
Reset
SYS
R.S.
1
DI
2
PWR
CONSOLE
115200.N.8.1
DO
Surge
Protect
Enable
Surge
Protect
Enable
Surge
Protect
Enable
JetNet 7310G是具有8端口IEEE 802.3at PoE / PSE千兆以太网共电口以及2千兆SFP光
纤口的工业型网络管理交换机。交换机每个端口具有35W共电能力,系统提供240W
PoE总共电功率。系统设计采用一体式散热模块为高阶DOM型网络监控摄像机,无
线AP存取时,进行高功率以太网供电时提供优异优异散热能力。 整体式散热结构设
计,即使在路侧机柜中工作,仍然可以为远端PoE-PD提供高功率。 它还采用综合网
络功能,具有辉煌的电磁敏感性检测水平,实现了铁路轨道及道路边 IP视频监控应
用的能力。
产品清单

JetNet 7310G

轨道夹扣

DB-9 to RJ-45 串口线

快速安装向导
5年质保
所有科洛理思产品的设计、制造及测试都是采用较高的工业标准。科洛理思保证
自产品出货日起提供最高5 年之免费保修服务,保修期间如因零件损坏或制程不
良而导致产品故障,我们提供免费维修服务。
自然外力 (火、水、雷灾)所造成的产品故障,或其它外部因素如电源干扰、不
当电源输入、不当接线等造成的损坏,不列入产品保固范围;此外,产品被误用、
未经授权的修理及修改等行为将造成保固条款失效。
注意! 请勿于电源开启时插拔接线端子,避免产生火花造成系统损坏。
此产品保证完全符合欧盟2003年1月27日电气和电子设备危害物质限制委员会限
用指令2002/95/EC (RoHS)及2011/65/EU(RoHS 2.0)。
Korenix售后服务
KoreCARE是Korenix全球服务中心,我们专业的技术人员随时准备解答您的疑问。
Korenix全球服务中心 EMAIL: [email protected]
详细文件下载: www.korenix.com.cn/support_downloads.htm
业务服务: [email protected]
官网: www.korenix.com.cn
客户服务
Patent No. (Taiwan):
Granted Invention: I 313547
Granted Invention: I 321415
Granted Invention: I 344766
Granted Invention: I 346480
Granted Invention: I 356616
Granted Invention: I 364684
Granted Invention: I 376118
Granted Invention: I 393317
Granted Invention: I 398066
Granted Invention: I 398125
Granted Invention: I 459757
Utility Model: M 339841
Utility Model: M 339840

准备控制面板界面软件
将RS-232 串口DB9连接到PC的串口。串口线的RJ-45连接器连接到JetNet交换机的
Console口。
1. 计算机开始

程序集

附属应用程序

通讯

超级终端机界面
2. 建立一个超级终端机联机名称
3.选择COM串口名称,并选择正确的串口设置。JetNet交换机的串口端口设置如
下:115200bps, N, 8,1
4. 连接后,你会看到交换机登录请求。输入用户名和密码,然后就可以登录。默
认用户名为“admin”,密码为“admin”。
5. 按照使用手册安装软件功能。
在网络管理上准备
1. 启动PC上的网页浏览器
2. 键入http://JetNet Managed Switch_IP_Address (默认IP地址是192.168.10.1),然
后按Enter键。
3.登录屏幕窗口待会将出现。在用户名和密码,键入单击“确定”按钮。基于Web的
管理界面的欢迎页面将出现即可。默认的用户名和密码是admin/admin。
4. 在Web管理接口的左侧栏的是交换机软件功能,其中点击环圈将列出可用的相
关设置细项。
轨道安装
该导轨卡夹已经收紧锁定在后侧面板,请采用并支持EN50022标准35mm 寬工业轨
道以便安装交换机。
界面介绍
JetNet 7310G 支持8端口千兆以太网电口及2个千兆以太网SFP插口支持 SFP光收发器
光纤传输。
连接电涌保护
电涌保护激活螺丝位于後方軌道扣具下方。务必拧紧螺丝,
确保机箱-接地螺丝与大地系统接地连接,以便取得良好的
浪涌雷击保护。
注意:
1.确保浪涌螺丝与机箱良好接地
2. 执行绝缘/耐压测试前, 请先拆下浪涌保护螺。测试后务
必锁回电涌保护激活螺丝。
3.切勿安装设备在雷电活动期以避免触电发生危险。
连接数字输入
数字输入(DI)接触是在该装置的底侧
。它接受一个外部直流信号输入,并且
可以配置为通过以太网发送警报消息时
当信号改变时。该信号可以触发并通过
外部电源开关产生的,就像是开门触发
开关控制柜。
注意:DI接受DC型信号隔离输入电路
,并支持使用数字高电平输入直流
11V~30V和数字低电平输入DC0V~10V。不要施加电压超过规格更高;它可能会造成
内部电路损坏或造成DI的一个永久性错误动作。
概述
Korenix Technology Co., Ltd.
(A Beijer Electronics Group Company)
Tel:+886-2-89111000
Fax:+886-2-29123328
Business service:[email protected]
Customer service:[email protected]
www.korenix.com
CPQ000N7310000
接线的电源输入与地球接地
1.将正和负导线插入V +和V-
接触端子台连接器上。
2. 连接机箱接地与系统大
地以便获得优良的电磁干
扰保护,如静电,浪涌放电
,快速脉冲放电。
3. 拧紧丝钳螺丝,以防止
电源线发生松弛。
注意:请采用国家核可具备安全规范的电源共应器,输出电压范围46~57 VDC,电
流共应不小于 2.5A,建议采用 53V 作为标准以太网供电操作电源电压。
连接继电器输出
继电器输出触点处于底侧上。继电器输
出(DO)是通过预先定义的操作规则
来控制。要激活继电器输出功能,请参
阅用户手册,了解详细继电器输出的管
理信息。
注意:继电器触点只支持0.5 A电流,
直流24V。不建议施加高于规格的电压
和负载电流。
安装
管理接口
JetNet 7310G工业管理型交换机提供了带内和带外配置方法。您可以通过RS-232控制
面板的连接控制面板电缆配置交换机。或者你也可以选择的Telnet/SSH,网络/
HTTPS进行远程网络管理交换机。
4
1 2
5 65
7 8
7
5
8
6
3
1
4
2
9
SYS
R.S.
1
DI
2
DO
Surge
Protect
Enable

Other Korenix Switch manuals

Korenix JetNet 3212G-2C2F User manual

Korenix

Korenix JetNet 3212G-2C2F User manual

Korenix JetNet 3205G Series User manual

Korenix

Korenix JetNet 3205G Series User manual

Korenix JetNet 5710G Series User manual

Korenix

Korenix JetNet 5710G Series User manual

Korenix JetNet 4508 V2 Series User manual

Korenix

Korenix JetNet 4508 V2 Series User manual

Korenix JetNet 4500 Series User manual

Korenix

Korenix JetNet 4500 Series User manual

Korenix JetNet 4508 User manual

Korenix

Korenix JetNet 4508 User manual

Korenix JetNet 6524G User manual

Korenix

Korenix JetNet 6524G User manual

Korenix JetCard 1204 User manual

Korenix

Korenix JetCard 1204 User manual

Korenix JetNet 4000 User manual

Korenix

Korenix JetNet 4000 User manual

Korenix JetNet 2005f User manual

Korenix

Korenix JetNet 2005f User manual

Korenix JetNet 3010G Series User manual

Korenix

Korenix JetNet 3010G Series User manual

Korenix JetNet 3008f User manual

Korenix

Korenix JetNet 3008f User manual

Korenix JetNet 3808G Series User manual

Korenix

Korenix JetNet 3808G Series User manual

Korenix JetNet 6059G User manual

Korenix

Korenix JetNet 6059G User manual

Korenix JetNet 5010G Series User manual

Korenix

Korenix JetNet 5010G Series User manual

Korenix JetNet 3705-24V User manual

Korenix

Korenix JetNet 3705-24V User manual

Korenix JetNet 701 User manual

Korenix

Korenix JetNet 701 User manual

Korenix JetNet 6710G User manual

Korenix

Korenix JetNet 6710G User manual

Korenix JetNet 3005 User manual

Korenix

Korenix JetNet 3005 User manual

Korenix JetNet 5428G Series User manual

Korenix

Korenix JetNet 5428G Series User manual

Korenix JetNet 3008f v3 User manual

Korenix

Korenix JetNet 3008f v3 User manual

Korenix JetNet 5210G User manual

Korenix

Korenix JetNet 5210G User manual

Korenix JetNet 4508i Series User manual

Korenix

Korenix JetNet 4508i Series User manual

Korenix JetNet 6710G User manual

Korenix

Korenix JetNet 6710G User manual

Popular Switch manuals by other brands

SMC Networks 8505T - annexe 1 user guide

SMC Networks

SMC Networks 8505T - annexe 1 user guide

Cisco MS420-24 installation guide

Cisco

Cisco MS420-24 installation guide

Hama 75122224 operating instructions

Hama

Hama 75122224 operating instructions

Eaton Z-NHK-LS Instruction leaflet

Eaton

Eaton Z-NHK-LS Instruction leaflet

C&H Technologies VX414C Specification sheet

C&H Technologies

C&H Technologies VX414C Specification sheet

3Com CoreBuilder 3500 Implementation guide

3Com

3Com CoreBuilder 3500 Implementation guide

Lantronix SLC 8000 Series user guide

Lantronix

Lantronix SLC 8000 Series user guide

Kinivo K301 user manual

Kinivo

Kinivo K301 user manual

Jasco ZW4104 manual

Jasco

Jasco ZW4104 manual

Multico EW-K1302DPUC4K Quick installation guide

Multico

Multico EW-K1302DPUC4K Quick installation guide

socomec Sirco MV 100 instruction sheet

socomec

socomec Sirco MV 100 instruction sheet

IOGear USB-C 8K Nano Dock Pro quick start guide

IOGear

IOGear USB-C 8K Nano Dock Pro quick start guide

EnOcean EASYFIT ESRPB user manual

EnOcean

EnOcean EASYFIT ESRPB user manual

IDK MSD-804FD Series Command guide

IDK

IDK MSD-804FD Series Command guide

Bucktool SSA16LVF instruction manual

Bucktool

Bucktool SSA16LVF instruction manual

Cisco 2950 - Catalyst Switch Software configuration guide

Cisco

Cisco 2950 - Catalyst Switch Software configuration guide

Cisco Catalyst PON Series Hardware installation guide

Cisco

Cisco Catalyst PON Series Hardware installation guide

Abocom TC08 Specification sheet

Abocom

Abocom TC08 Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.