Kramer SL-10 User manual

Kramer Electronics, Ltd.
Preliminary
USER MANUAL
Model:
SL-10
Master Room Controller
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

Contents
i
Contents
1Introduction 1
2Getting Started 1
2.1 Achieving the Best Performance 2
2.2 Safety Instructions 2
2.3 Recycling Kramer Products 2
2.4 Quick Start 3
3Overview 4
4Your SL-10 Master Room Controller 5
5Connecting the SL-10 Master Room Controller 6
5.1 Using the RC-4 IR transmitter 7
5.2 Connecting the RS-232 Interface 8
5.3 Connecting the RS-485 Interface 8
5.4 Connecting the Ethernet Port 9
5.5 Connecting the K-NET Port 9
6Operating the SL-10 Master Room Controller 10
7Technical Specifications 10
Figures
Figure 1: SL-10 Master Room Controller 5
Figure 2: Connecting the SL-10 Master Room Controller 7
Figure 3: RS-232 Connection 8
Figure 4: RS-485 Connection 8
Figure 5: K-NET PINOUT Connection 9
Tables
Table 1: SL-10 Master Room Controller Functions 5
Table 2: SL-10 Master Room Controller Technical Specifications 10
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

Introduction
1
1
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast
range of problems that confront the video, audio, presentation, and
broadcasting professional on a daily basis. In recent years, we have
redesigned and upgraded most of our line, making the best even better! Our
1,000-plus different models now appear in 11 groups1
Thank you for purchasing the Kramer MultiTOOLS®SL-10 Master Room
Controller, which is ideal for:
that are clearly
defined by function.
•Controlling multimedia rooms, such as classrooms, auditoriums,
conference rooms, and so on, while enabling remote control and
management of the AV equipment
•Production studios, rental, and staging
2 Getting Started
We recommend that you:
•Unpack the equipment carefully and save the original box and
packaging materials for possible future shipment
•Review the contents of this user manual
i
Go to http://www.kramerelectronics.com to check for up-to-date
user manuals, application programs, and to check if firmware
upgrades are available (where appropriate).
1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; GROUP 3: Control Systems;
GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products;
GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity;
GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Products
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Getting Started
2
2.1 Achieving the Best Performance
To achieve the best performance:
•Use only good quality connection cables (we recommend Kramer high-
performance, high-resolution cables) to avoid interference,
deterioration in signal quality due to poor matching, and elevated noise
levels (often associated with low quality cables)
•Do not secure the cables in tight bundles or roll the slack into tight coils
•Avoid interference from neighboring electrical appliances that may
adversely influence signal quality
•Position your Kramer SL-10 away from moisture, excessive sunlight
and dust
!
This equipment is to be used only inside a building. It may only be
connected to other equipment that is installed inside a building.
2.2 Safety Instructions
!
Caution: There are no operator serviceable parts inside the unit
Warning: Use only the Kramer Electronics input power wall
adapter that is provided with the unit
Warning: Disconnect the power and unplug the unit from the wall
before installing
2.3 Recycling Kramer Products
The Waste Electrical and Electronic Equipment (WEEE) Directive
2002/96/EC aims to reduce the amount of WEEE sent for disposal to
landfill or incineration by requiring it to be collected and recycled. To
comply with the WEEE Directive, Kramer Electronics has made
arrangements with the European Advanced Recycling Network (EARN) and
will cover any costs of treatment, recycling and recovery of waste Kramer
Electronics branded equipment on arrival at the EARN facility. For details
of Kramer’s recycling arrangements in your particular country go to our
recycling pages at http://www.kramerelectronics.com/support/recycling/.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

Getting Started
3
3
2.4 Quick Start
This quick start chart summarizes the basic setup and operation steps.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Overview
4
3 Overview
The SL-10 is a highly versatile controller that acts as an all-in-one control
processor for control of A/V equipment—especially projectors and
associated equipment—in any room (such as classrooms, boardrooms, or
auditoriums). It streamlines operations and simplifies control by integrating
audio, video, and computer-video sources into a centralized system.
The SL-10 Master Room Controller features:
•An Ethernet port for controlling several AV products over ETH
•2 general purpose I/O ports that can be configured as analog inputs,
digital inputs, or digital outputs for interfacing with a variety of
devices such as sensors, switches, LEDs, and relays
•2 bidirectional RS-232 ports that control AV equipment such as
projectors, LCD and PDP displays, power amplifiers, switchers and
scalers
•5 relay contact closure ports that control other room items related to
the AV system such as raising and lowering drapes, the screen or the
projector
•IR control on two inputs (one built-in receiver and the other on a
3.5mm mini jack) and three outputs (on terminal blocks)
•IR Learning that learns commands from any IR remote
•1 RS-485 serial port
•Compatibility with Kramer Site-CTRL software for network remote
control and management over the Ethernet port
•A K-NET™ control channel that connects compatible user interfaces
and supplies power and control data over a single cable
•A USB port for uploading a configuration file
•Status LEDs for all functions
•Flexible control via Ethernet, K-NET™, RS-485, an IR sensor and
external IR commands
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

Your SL-10 Master Room Controller
5
5
4 Your SL-10 Master Room Controller
Figure 1 and Table 1 define the unit.
Figure 1: SL-10 Master Room Controller
Table 1: SL-10 Master Room Controller Functions
# Feature Function
1 ETHERNET RJ-45
Connector
Connects to the PC or other serial controller through computer
networking LAN to control several AV products over Ethernet
2 DEFAULT Recessed
Pushbutton
Press to reset to factory default definitions1
3
:
IP number −192.168.1.39, Mask – 255.255.0.0
Gateway – 0.0.0.0
IR Output Terminal Blocks Connect to IR emitter cables (from 1 to 3)
4 GPI/O Terminal Blocks Connect to various analog and digital sensors (from 1 to 2)
5 RELAYS Terminal Blocks Connect to low-voltage relay-driven devices (from 1 to 5)
6 RS-232 Terminal Blocks Connect to the RS-232 devices (from 1 to 2)
7 RS-485 Terminal Block Pins B (-) and A (+) are for RS-485; Pin G may be connected to the
shield (if required)
8 K-NET
2
PIN GND is for the Ground connectionConnector
3
; PIN B (-) and PIN A (+) are
for RS-485, and PIN +12V is for powering other units4
9
RS-485 TERM Switch Slides down for RS-485 termination, slides up for not terminated
10 K-NET TERM Switch Slides down for K-NET termination, slides up for not terminated
1 First disconnect the power supply and then connect it again while pressing the DEFAULT button. The unit powers up and
loads its memory with the factory default definitions and erases all stored presets
2 K-NET is a proprietary Kramer protocol for interconnecting Kramer units
3 The ground connection is sometimes connected to the shield of the RS-485 cable (in most applications, it is not connected)
4 Note that the SL-10 cannot receive power via the K-NET connector, but can power other units (but not another SL-10)
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Connecting the SL-10 Master Room Controller
6
#
Feature
Function
11 PROG. Switch For service use only
12 12V DC Socket 12V DC connector for powering the unit
13 IR
INPUTS
built-in receiver
and STATUS LED
Accepts IR remote commands
14 3.5mm Mini Jack Connects to an external IR receiver
15 RELAY LEDs Illuminate when a relay is active (1 to 5)
16 IR LEDs Illuminate when an IR port is active
17 NET LED Illuminates when The Ethernet link is active
18 K-NET LED Illuminates while transmitting over K-NET
19 RS-485 LED Illuminates while transmitting/receiving on an RS-485 port
20 RS-232 (Tx/Rx) LEDs Illuminate while transmitting/receiving on an RS-232 port
(1 to 2)
21 GPI/O LEDS Illuminate while transmitting/receiving on a general purpose I/O port
(1 to 2)
22 PROGRAM USB Connector Connect to a computer for unit configuration and firmware upgrading
5 Connecting the SL-10 Master Room Controller
To connect the SL-10, as the example in Figure 2 illustrates, do the following1
1. Connect the RELAY terminal block connectors as follows:
:
Connect RELAY 1 and 2 to the projector lift
Connect RELAY 3 and 4 to the screen
Connect RELAY 5 to the lighting system
2. Connect the IR outputs as follows:
Connect an IR emitter to IR OUTPUT 1 and attach the emitter to
the DVD player
3. Connect the GPI/O ports as follows:
Connect GPI/O 1 to motion detector 1
Connect GPI/O 2 to motion detector 2
4. Connect the RS-232 ports as follows:
Connect RS-232 port 1 to the DVD player
Connect RS-232 port 2 to the projector
5. Connect the IR input as follows:
Connect IR INPUT 1 to an IR sensor (or alternatively connect IR
INPUT 1 to an external IR receiver 2
1 Switch OFF the power on each device before connecting it to your SL-10. After connecting your SL-10, switch on its power
and then switch on the power on each device
2 P/N: C- A35M/IRR two extension cables are also available: a 15 meter cable and a 20 meter cable
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

Connecting the SL-10 Master Room Controller
7
7
6. Connect the RS-485 to several Kramer matrices, for example1
7. Connect the Ethernet port to a network.
.
8. Connect the K-NET port to any RC device with K-NET.
Figure 2: Connecting the SL-10 Master Room Controller
5.1 Using the RC-4 IR transmitter
You can use the optional RC-4 IR transmitter as an auxiliary control panel
and initiate configured control triggers—refer to the K-Config guide—via
the built in IR receiver on the front panel, or instead, via an optional
external wired IR receiver2
Figure 2
, which exists in several cable lengths (shown in
).
1 Not shown in Figure 2
2 Model: C-A35M/IRR-50
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Connecting the SL-10 Master Room Controller
8
5.2 Connecting the RS-232 Interface
To connect an AV device to the SL-10 using the RS-232 port, connect the
RS-232 9-pin D-sub port on your device to the RS-232 terminal block on
the rear panel of the SL-10 as shown in Figure 3:
Figure 3: RS-232 Connection
5.3 Connecting the RS-485 Interface
To connect an AV device to the SL-10 using the RS-485 port, connect the
RS-485 port on your device to the RS-485 terminal block on the rear panel
of the SL-10 as shown in Figure 4:
Figure 4: RS-485 Connection
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

Connecting the SL-10 Master Room Controller
9
9
5.4 Connecting the Ethernet Port
The Ethernet connection of the SL-10 allows you to perform all control
functions of the SL-10 over the Internet using a PC running the Kramer
Site-CTRL control program.
To connect the SL-10 to a network:
1. Connect the Ethernet port of the SL-10 to the Ethernet port on a
network hub or network router, via a straight cable with RJ-45
connectors.
2. At the other end, connect the Internet to a PC running Site-CTRL.
After connecting the Ethernet port, you have to install and configure it. For
detailed instructions on how to install and configure your Ethernet port, see
the K-Config Guide1
5.5 Connecting the K-NET Port
.
The K-NET port is wired as shown in Figure 5.
Figure 5: K-NET PINOUT Connection
1 Available for download at the Kramer Web site: www.kramerelectronics.com
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Operating the SL-10 Master Room Controller
10
6 Operating the SL-10 Master Room Controller
You can operate your SL-10 using:
•An RC family remote controller:
To operate your device using an RC remote controller, see the Kramer
K-Config Guide1
•The optional RC-4 infrared remote control transmitter
2
•A PC running Site-CTRL control software:
To operate your device using Site-CTRL, see the Site-CTRL and
Web Access Online User Guide
:
To operate your device using the infrared remote controller, see the
User Manual packed with the remote controller
1
7 Technical Specifications
The SL-10 technical specifications are shown in Table 2:
Table 2: SL-10 Master Room Controller Technical Specifications3
INPUTS:
2 RS-232, RS-485, 2 GPI/O and K-NET on terminal block connectors;
Ethernet on an RJ-45 connector; 1 infrared built-in receiver,
1 infrared on a 3.5mm mini jack connector; 1 USB for programming
OUTPUTS: 3 infrared, 5 relays (36V AC or DC, 2A, 60VAC maximum on non-inductive
load) and 2 GPI/O on terminal block connectors
DEFAULT IP SETTINGS: IP number − 192.168.1.39; Mask – 255.255.0.0; Gateway – 0.0.0.0
INDICATORS: LED indicator for each function
POWER SOURCE: 12V DC, 290mA
DIMENSIONS 14.3cm x 12.2cm x 4.4cm (5.6" x 4.8" x 1.7") W, D, H
WEIGHT: 0.6kg (1.4lbs)
ACCESSORIES: Power supply
OPTIONS: RK-13 19” rack mount, RC-4 remote controller, IR emitter cables
4
, IR sensor
cable5
1 Available for download at the Kramer Web site: www.kramerelectronics.com
2 The RC-4 is configured via the Kramer K-Config software
3 Specifications are subject to change without notice
4 P/N: C-A35/IRE-10; two IR Emitter Extension Cables are also available: a 15 meter cable and a 20 meter cable
5 P/N: 95-0104050
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203

Kramer Electronics, Ltd.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
P/N: 2900-000581 REV 3
For the latest information on our products and a list of Kramer
distributors, visit our Web site: www.kramerelectronics.com
where updates to this user manual may be found.
We welcome your questions, comments and feedback.
Caution
Safety Warning:
Disconnect the unit from the power supply before
opening/servicing.
P/N:
2900- 000581
Rev:
3
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203
Other manuals for SL-10
1
Table of contents
Other Kramer Controllers manuals

Kramer
Kramer SL-12 User manual

Kramer
Kramer KT-107-INWL User manual

Kramer
Kramer RC-76R User manual

Kramer
Kramer VA-4H User manual

Kramer
Kramer RC-62 User manual

Kramer
Kramer RC-52N User manual

Kramer
Kramer FC-10ETH User manual

Kramer
Kramer SL-280 User manual

Kramer
Kramer SL-280 User manual

Kramer
Kramer RC-7B User manual

Kramer
Kramer SL-240C User manual

Kramer
Kramer FC-18 User manual

Kramer
Kramer RC-43SL User manual

Kramer
Kramer 860 User manual

Kramer
Kramer RC-63DLN User manual

Kramer
Kramer SL-14RC User manual

Kramer
Kramer RC-6 User manual

Kramer
Kramer FC-18 User manual

Kramer
Kramer PL-50 User manual

Kramer
Kramer RC-13TC User manual