Model 2718
Temperature Probe
SAFETY :
over voltage & double insulation standard
?IEC/EN61010 CAT II 600V, CAT III 300V
SPECIAL FEATURES :
?Auto Polarity display
?Sleep Mode (can be disabled)
?Data Hold & Max. Hold Function
?Continuity & Diode Measurements
?Auto Power Off
?Low Battery Indication
GENERAL SPECIFICATIONS :
íSensing : Average Sensing
íJaw Opening Size : 26mm diameter
íDisplay : 3½ digits 2000 counts LCD display
íDisplay Size : 17mm
íMax. Jaw Size : 28mm diameter
íMeasurement Speed : Update 3 times/second.
íLow Battery : “ ” sign appears on the display
íOver range indication : Display “OL” or “-OL”
íTemperature Coefficient :
0.1°C (specified accuracy)/°C
ACCESSORIES :
Test leads, Carrying Case, Battery installed, User's
Manual, Drop proof wrist strap & Temperature Probe
íStorage Temperature : -20°C to 60°C, <75% R.H.
íMeasurement Deviation : When the conductor being
measured is not placed in a correct position during
AC Current measurement.
It will cause ±1% reading deviation.
íOperating Temperature : 0°C~30°C; <75% R.H.;
30°C~40°C; <70% R.H.; 40°C~50°C; <45% R.H.
íPower Supply : 1.5VAAA battery x 2
íDimension : 208(L) X 76(W) X 30(H) mm
íWeight : Approx. 260 gm (battery included)
ELECTRICAL SPECIFICATIONS - 2718
Accuracy is ± (% reading digits + number of digits ) or otherwise specified, at 23°C ± 5°C & less than 75% R.H.
Range
2.000 A 1 mA ±(3%rdg + 12dgts)
AC CURRENT (Auto Ranging)
Accuracy
Resolution
20.00 A 10 mA ±(2%rdg + 8dgts)
200.0 A 100 mA
400 A 1 A ±(1.0%rdg + 9dgts)
Frequency Response : 50Hz ~ 60Hz
Overload Protection : 400Arms
?Display effective value of sine wave (mean value response)
To adjust reading in accordance with effective value.
Range
200.0 W100 mW
±(1.2%rdg + 2dgts)
2.000 kW
1 W
±(1%rdg + 2dgts)
20.00 kW10 W
200.0 kW100 W
RESISTANCE (Auto Ranging)
Accuracy
Resolution
Overload Protection : 600V rms
Input Impedance : 10MW
2.000 MW
1 kW
20.00 MW10 kW
±(1.5%rdg + 2dgts)
±(1.2%rdg + 2dgts)
-40°C~1000°C
TEMPERATURE(K-Type Thermocouple)
1°C
Accuracy
Resolution
Range
-40~0°C:
±(3%rdg+9dgts)
0~400°C:
±(1%rdg+7dgts)
400~1000°C:
±(2%rdg+10dgts)
-40°F~1832°F 1°F
-40~32°F
±(3%rdg+10dgts)
32°F~752°F
±(1%rdg+8dgts)
752°F~1832°F
±(2%rdg+18dgts)
Overload Protection : 600V rms
Thermocouple accuracy not included.
Supplied Thermocouple is suitable for measurement upto 250°C
2.000 V 1 mV
20.00 V 10 mV
200.0 V 100 mV
600 V 1 V
AC VOLTAGE (Auto Ranging)
±(1.2%rdg + 5dgts)
±(1.5%rdg + 5dgts)
Accuracy
Overload Protection : 600V rms
Input Impedance : 10MW/ <100pF
Display effective value of sine wave (mean value response)
Frequency response : 40Hz~1kHz
To adjust reading in accordance with effective value.
Range Resolution
Range
1 mV Display Approximate
forward Voltage
Drop:0.5V~0.8V
DIODE TEST
Accuracy
Resolution
Open Circuit Voltage : Approx. 1.48V
Overload Protection : 600V rms
Range
100 mW
Around £50W
the buzzer beeps
CONTINUITY TEST
Accuracy
Resolution
Open Circuit Voltage : Approx. 0.45V
Overload Protection : 600V rms
The buzzer may or may not beeps when the resistance of a circuit
under test is between 50Wand 120W.
The buzzer may not beep when the resistance of a circuit under
test is greater than 120W.
DC VOLTAGE (Auto Ranging)
2.000 V 1 mV
20.00 V 10 mV
200.0 V 100 mV
600 V 1 V
200.0 mV 100 mV
Accuracy
±(0.8%rdg + 1dgts)
±(1%rdg + 3dgts)
±(0.8%rdg + 3dgts)
Range Resolution
Overload Protection : 600V rms
Input Impedance : 10MW
±(4%rdg +30dgts)£1A
±(3%rdg +12dgts)£4A
13 FUNCTIONS 20 RANGES
3½ DIGITS AC DIGITAL CLAMPMETER