Kymeta u7 Series User manual

Kymeta™ u7 Terminal Quick Start
Guide
Document number: 700-00009-001-revD
For Kymeta™ u7x terminal, Kymeta™ u7m terminal, and Kymeta™ u7h terminal
06 March 2019

Table of contents
1 Introduction 1
2 Specification 1
3 Package contents 2
4 Indoor unit components and cables 3
5 Tools required 4
6 Provision and commission 4
7 Prepare the outdoor unit (ODU) 5
8 Connect the cables 6
9 Power on the u7 terminal 7
10 Access the u7 antenna 7
11 Access the modem 7
12 Documentation 7
13 CE declaration of conformity 8
14 FCC notifications 8
15 Contact information 8
16 Revision history 9
17 Copyright and trademark information 9

© 2019 Kymeta Corporation and its affiliates. 1 06 March 2019
Kymeta™ u7 terminal quick start guide
1 Introduction
Thank you for choosing the Kymeta™ u7 terminal and welcome to the new era of satellite connectivity.
To ensure the u7 terminal is installed for maximum performance in each deployed platform, only Kymeta-certified
installers should install and commission the unit.
2 Specification
Input power 110 VAC to 240 VAC 50/60 Hz
(system values dependent on BUC)
Power consumption 8 W BUC: 300 W (typical) | 500 W (peak)
16 W BUC: 400 W (typical) | 600 W (peak)
Outdoor unit dimensions L 82.3 cm × W 82.3 cm × 16.5 cm
(L 32.4 in. × W 32.4 in. × D 6.4 in.)
Outdoor unit weight u7x, u7h: 18.14 kg (40 lb.)
u7m: 20.41 kg (45 lb.)
I/O box dimensions W 48.26 cm × D 22.21 cm × H 4.37 cm
(W 19 in. × D 8.745 in. × H 1.72 in.)
iDirect X7 modem dimensions W 44.5 cm × D 30.5 cm × H 4.37 cm
(W 17.5 in. × D 12 in. × H 1.72 in.)
Indoor unit weight 6.35 kg (14.0 lb.)

© 2019 Kymeta Corporation and its affiliates. 2 06 March 2019
Kymeta™ u7 terminal quick start guide
3 Package contents
Box Contents
Box 1: u7 terminal ODU (1) Pre-assembled ODU (ODU mounting plate (attached RF chain - BUC,
diplexer, LNB) installed on antenna)
(6) Cable ties
(1) 700-00009-001 Kymeta™ u7 terminal quick start guide
(1) 700-00008-001 Kymeta safety and handling guide
(1) 700-00011-000 Kymeta™ u7 terminal limited warranty
Box 2:ODUinterface cable (1) ODU interface cable (three lengths available: 3.66 m, 7.62 m, 15.24 m)
Box 3:I/O box (1) I/O box
(1) Power cable
(8) Screws and nuts
Box 4:Modem (1) Modem
(1) Power cable
(8) Screws and nuts
(1) Ethernet cable
(2) N-type to F-type adapter
RF cables (accessory) (1) RX cable (three lengths available: 3.66 m, 7.62 m, 15.24 m)
(1) TX cable (three lengths available: 3.66 m, 7.62 m, 15.24 m)

© 2019 Kymeta Corporation and its affiliates. 3 06 March 2019
Kymeta™ u7 terminal quick start guide
4 Indoor unit components and cables
✎Screw two N-type to F-type adapters to the RX IN port (RX 1) and TX OUT port connectors at the back of the
modem.
Note: Drawings are not to scale
✎The I/O box vents are on top of the box, so always place the I/O box on the top rack. Standard rack spacing
allows sufficient ventilation.

© 2019 Kymeta Corporation and its affiliates. 4 06 March 2019
Kymeta™ u7 terminal quick start guide
5 Tools required
Note that installation tools are not provided with the product.
Tool diagram Tool description
Torque screwdriver with 3 in. (minimum) ball head extension
0.2 N-m (2 in.-lb.) minimum torque rating
Hex bit
4 mm for the I/O box and the modem
Break-over torque wrench for N-type connectors
0.9 N-m (8.1 in.-lb.) torque rating
6 Provision and commission
With the purchase of KĀLO™ services, Kymeta provides customers with the ability to provision Kymeta u7 terminals on
the KĀLO network services to assure that all systems and components are fully operational.
Refer to the 700-00022-000 Provisioning and commissioning KĀLO™ services customer guide when performing initial
configuration and commissioning for KĀLO network services.
For all other networks, contact Kymeta customer support at support@kymetacorp.com
or 1-855-525-6638 (Monday to Friday, 07:00-18:00 Pacific Time (UTC-8)) to schedule your commissioning window.

© 2019 Kymeta Corporation and its affiliates. 5 06 March 2019
Kymeta™ u7 terminal quick start guide
7 Prepare the outdoor unit (ODU)
1. Make sure you have a clear, clean, flat surface for assembling the Kymeta u7 terminal.
2. Open the u7 terminal ODU box. With two people, lift the ODU out of the case. Lift by the plastic bezel only.
Do not lift the ODU by any RF component (LNB, diplexer, or BUC) as this may damage sensitive
components and potentially void your warranty.
⚠The diplexer is a precision tuned piece of RF equipment and not a structural member of the u7 terminal.
Kymeta recommends that installers, integrators, and handlers of the terminal do not lift or hold the terminal
by using any of the RF chain as a handle or grip.
3. Lay the ODU on a face down on a clean level surface.
4. Attach mounting hardware and cables (depending on ODUconfiguration).
5. Refer to the Connect the cables section for further instructions.

© 2019 Kymeta Corporation and its affiliates. 6 06 March 2019
Kymeta™ u7 terminal quick start guide
8 Connect the cables
Avoid confusing the RX and TX cables. Before installing the cables, apply colored tape to each end of the cable, or install
one cable at a time. The recommended convention is RED for the TX cable and BLUE for the RX cable.Finger-tighten all
N-type and connector cables.
1. Connect the ODU interface cable 31-pin connector to the back of the antenna by carefully aligning the connector
keys on the inside bulk and on the inside of the outer ring. The connector should seat firmly without forcing it. You
may feel a slight click as the connector seats into place.
2. Connect the ODU interface cable 12-pin Amphenol connector to the 12-pin receptacle on the BUC.
3. Connect the TX cable (RED) to the BUC, hand-tighten.
4. Connect the RX cable (BLUE) to the antenna RX OUT port, hand-tighten.
5. Connect the ODU interface cable 18-pin connector to the I/O box.
6. Screw an N-type to F-type adapter to the RX IN port (RX 1) connector at the back of the modem, and then
connect the RX cable (BLUE), hand-tighten. Do not use the RX 2 port.
7. Screw an N-type to F-type adapter to the TX OUT port connector at the back of the modem, and then connect the
TX cable (RED), hand-tighten.
8. Connect the Ethernet cable to the I/O box and port 1 (bottom left) on the modem.
9. (optional) Connect the customer Ethernet cable to the modem (port 5-8 for DHCP).
10. Connect one power cable to the I/O box and another one to the modem.
✎Use cable ties to clean up loose cables.

© 2019 Kymeta Corporation and its affiliates. 7 06 March 2019
Kymeta™ u7 terminal quick start guide
9 Power on the u7 terminal
1. Check that all cables are connected, as shown in the Connect the cables section.
2. Power on the I/O box and confirm that the power light on the front is solid green.
3. Confirm that the light on the back of the antenna is solid green.
4. Power on the modem and confirm that the Power, Status, and Temp lights on the front are solid green.
5. Wait 90 seconds, and then verify that the Ethernet port 1 link light on the back side of the modem is blinking.
10 Access the u7 antenna
Kymeta supports Chrome and Firefox browsers.
To access the u7 antenna web-based user interface, do the following:
1. Connect an available Ethernet port on your laptop to the Ethernet port 2 on the modem.
2. Configure the TCP/IPv4 properties of the Ethernet port on your laptop to use static IP address/subnet mask of
192.168.44.3 /255.255.255.0.
3. In your browser, go to http://192.168.44.2.
4. In the Authentication Required window, provide the following credentials: username: admin, password:
2Cfg^Ant.
✎When you connect directly to the antenna through the I/O box via Ethernet, set your laptop IP address to
192.168.0.11, and reach the antenna at the IP address 192.168.0.10.
✎Refer to 700-00020-000 Kymeta™ u7 terminal troubleshooting guide, section "Cannot access the web-based
UI" if you cannot access the antenna.
The u7 antenna automatically reboots every 7 days. To set the auto-reboot time based on the current user's local time
zone, go to the Settings page > System window, and then update the time in the Auto Reboot Time field.
11 Access the modem
Do not make changes to your modem until you talk to a KᾹLO™service representative. To access the modemprior to
commissioning, refer to 700-00032-000 Kymeta™ u7 terminal user manual.
12 Documentation
To obtain the most current version of the Kymeta u7 terminal documentation, check the Kymeta Partner Portal or
contact your Kymeta representative.

© 2019 Kymeta Corporation and its affiliates. 8 06 March 2019
Kymeta™ u7 terminal quick start guide
13 CE declaration of conformity
This equipment conforms with the essential requirements and other relevant provisions of:
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
Restriction of the use of certain hazardous substances (RoHS) Directive 2011/65/EU
Radio Equipment Directive (2014/53/EU)
14 FCC notifications
This device complies with Part 15B of the FCC rules. Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
This product complies with the requirements set forth in CFR 47 Section 1.1307 addressing RF Exposure from radio
frequency devices as defined in Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency
Electromagnetic Fields.
This product complies with EN 50835 for RF exposure.
The product is a transmit and receive satellite terminal; the user must comply with all applicable local, national, and
international laws and regulations regarding the installation and use of this product.
15 Contact information
12277 134th Ct NE, Redmond, WA 98052, USA | +1 (425) 896-3700 www.kymetacorp.com
twitter.com/KymetaCorp | facebook.com/kymetacorp | instagram.com/kymeta | linkedin.com/company/kymeta-
corporation

© 2019 Kymeta Corporation and its affiliates. 9 06 March 2019
Kymeta™ u7 terminal quick start guide
16 Revision history
Revision Change
A Initial document.
B Removed section "Assemble Outdoor Unit." Edited steps in section "Prepare the ODU." Updated "Access
the u7 antenna"to cover software version 1.1.0.3240.
C Added a note to section "Access the u7 antenna".
D Updated product names to reflect new branding guidelines. Updated to support the following terminal
configurations: u7m, u7h, and u7x.
17 Copyright and trademark information
© 2019 Kymeta Corporation and its affiliates. KYMETA, CONNECTED BY KYMETA, MTENNA, KĀLO image, and KĀLO are
trademarks of Kymeta Corporation, with registrations or pending applications for these marks in Brazil, the European
Union, Japan, Norway, Singapore, South Korea, and the United States.
All other trademarks are the property of their respective owners.
Other manuals for u7 Series
3
This manual suits for next models
3
Table of contents
Other Kymeta Touch Terminal manuals