Laskomex Bastion Apus User manual

Video door phone set
manual
Bastion Apus

- 1 -
CONTENTS
1. Operating conditions 2
2. Purpose and characteristics of video door phone set 2
3. Elements of Apus video door phone set 3
- MVC-7001 monitor 3
- BVC-6503 external panel 3
- ZS-15 feeder 4
Optional elements:
- Electro-catch 4
- Electro-catch feeder 4
4. Before the assembly 4
- Specify the places where elements are to be mounted 4
- Electric installation of video door phone 5
- Block diagrams 6
- Connection diagrams 6
5. Assembly and connecting elements of video door phone 8
- Assembly and connection MVC-7001 monitor 8
- Assembly and connection the external panel BVC-6503 8
- Feeder assembly 9
- Assembly of electro-catch 9
6. Operating video door phone 9
7. Maintance 10
8. Programming mode in external panel BVC-6503 10
9. Technical data 11

- 2 -
1. OPERATING CONDITIONS
- Before installing and using the video door phone, read the assembly and operating
manual.
- Electrical installation should be made in accordance with PN-IEC 60364-1 standard
by an authorized person.
- Electrical installation should be made in such a way as to prevent exposure to direct
lightning discharge.
- Video door phone elements should be used as intended. Using video door phone
elements for other purposes, including with equipment other than specified in the
manual or connecting them in other manner than prescribed by the manufacturer may
lead to their damage, fire or electric shock.
- Do not cover the openings in the monitor housings.
- Do not insert any metal items in the openings in the monitor housing and the feeder
as it may lead to electric shock or fire.
- The external panel should be installed in a place with low noise level.
- The external panel is powered with video door phone voltage. +Vcc and GND clamps
on the external panel should not be connected to an external feeder.
- Video door phone elements should be connected to an electrical installation when the
feeder is disconnected from the power network.
!
NOTE!
For affirmation of safety put on the mains terminal
covering (plastic element attached to the feeder)
after connect the feeder to the mains.
Covering installation method is shown on
drawing. All the connection make with
the power supply turn off.
2. PURPOSE AND CHARACTERISTICS OF VIDEO DOOR PHONE
- Video door phone is designed for single family houses, companies, institutions and
service providers.
- Two monitors may be connected to the external panel.
-To external panel you can connect additional button to opening
the door.
-Monitor featured with colour display is used in the video door phone. It is a hands free
duplex monitor (two-way voice communication without manual control of call direction).
- The external panel is wall-mounted.
- The panel is equipped with a colour camera and a LED display facilitating viewing
visitors faces at night.

- 3 -
Figure 1. MVC-7001 videomonitor
3. ELEMENTS OF APUS VIDEO DOOR PHONE
MVC-7001 monitor
Hands free screen equipped with 5,8'' colour display. It is possible to set screen
brightness, color and volume of the monitor. Function buttons allow for answering calls,
launching viewing, transfering conversation to the second monitor (optional) and door
release.
BVC-6503 external panel
Vandal-proof panel with a colour camera, camera illuminator, loudspeaker, microphone,
release button and keypad access with call button. The panel is wall-mounted. The
panel is equipped with a transmitter releasing electro-catch after the button on the
monitor is used or user use keypad access.
Figure 2. BVC-6503 external panel
Screen
Microphone
Transfer
conversation
Electric door strike/
end of conversation
Conversation/
screening
Loudspeaker
LED indication
VolumeColor Brightness
CCD kamera
Water cover
Keypad Access
Camera illumination
Call button
Light sensor
LED indication
Mic

- 4 -
The set is additional featured with:
- assembly rail
- assembly screws
- pins necessary to connect the set
Additional elements:
Electro-catch
Electro-catch of 12V AC/1A max. should be used in the video door phone. While
selecting the electro-catch, take into account the mechanical build and type (left or
right) of the door or gate to be blocked. Electro-catch of Openers&Closers company
may be used (technical details at: www.laskomex.com.pl).
Feeder to electro-catch
ACV feeder: 12V AC/800 mA to mount on a DIN rail. Used to power to electro-catch.
Caution!!
Higher listed elements are not included in basic set.
4. BEFORE THE ASSEMBLY
Specify the places where video door phone elements are to be mounted.
- Mount the monitor in a place not exposed to strong light (e.g. close to the lamp,
window etc.) as it may obstruct viewing image on the screen.
- Do not mount the monitor in place where it could be exposed to humidity e.g. in
bathrooms.
- Do not mount the monitor near the sources of strong electromagnetic interference
(wiring, TV sets etc.)
- Do not mount the monitor in heating sources - stoves, radiators etc.
- The external panel should be mounted in such a place that the camera lens is not
ZS-15 feeder
DCV feeder, 15V DC/800 mA to mount on DIN rail.
Used to power the monitor and indirectly the external panel.
Figure 3. ZS-15 DCV feeder
AC
230 V
DC
15V/800mA

- 5 -
directed to light source (sun, strong lamp post) because it will significantly obstruct
or prevent viewing the visitors' faces.
- The image on the screen depends on the height the panel is mounted at. The
recommended height is ca. 150 cm. Such height allows for viewing the face of an
adult of average height standing ca. 50 cm from the panel. The assembly height should
be determined on a trial basis.
- Do not mount the external panel at the distance exceeding 60 m from monitor (with
the appropriate cable sections).
- Mount the feeder inside, in a place not exposed to humidity. Feeder should be mounted
on a DIN rail in the electric installation box.
- The above recommendations relate to both the monitor feeder and door strike feeder.
The door strike feeder may be mounted near the external panel (e.g. in the installation
box of fence pillar).
Electric installation of video door phone.
Elements of video door phone may be connected with any cable with section meeting
the requirements specified in Table 1.
At the distances between the monitor and the external panel exceeding 30 m, a 75
coaxial cable should be used to transmit video signal. The coaxial cable should be
connected as presented in Figure 7.
The maximum distance between the external panel and the monitor should not exceed
60 m.
To put down in the ground and outside the room it is necesarry to use the damp-proof
cables. The number of wires in the cables is shown on the single line diagram (fig. 4).
NOTE: It is necessary to pay special attention on quality of connection`s wires and
also on proper isolation of every connection especially when weather conditions
appears. It is recommended to use hermetic cable box and shrink wrap in the
place of joint the wires.
Maladjustment to those recommendation may lead to the impropriety activity
of the door phone set.
+Vcc,GND,audio
video
Table 1. Minimum cable section according to the distance between door phone elements
0,4mm2
<15m <30m
0,75mm2
Coaxial cable
<60m
1mm21.5mm22.5mm2
maximum 4m,
Distance
Connection
external panel - monitor
DCV feeder - external panel
DCV feeder - monitor
DCV feeder - 230V
monitor - monitor
1mm2
0,75mm2
0,75mm2
0,4mm2
0,75mm2

- 6 -
Figure 4. Connection of Apus video door phone - single line diagram.
b) How to youse clamps in external panel.
Figure 5. Block diagram of connecting elements of Apus video door phone
+ -~ ~
BVC-6503
Electro-catch
feeder
ZS-15
J103 J100
Electro-catch
Wiring in external panel
ZS-15
2
230V 2
4
BVC-6503
Electro-catch*
MVC-7001
~230V
~230V
2
2
2
2
2
4
MVC-7001 ZS-15
Electro-catch
feeder*
Electro-catch
Electro-catch
reversible or
MVC-7001
Optional - connecting
second monitor
b)
Description of clamps with connected
electro-catch
PURPLE(VIDEO)
WHITE(AUDIO)
BLACK(power GND)
RED(+12V)
AC/DC
MVC-7001 monitor
clamps on
backside
of panel
AUDIO
VIDEO
EGR
OV
NO
COM
+12V
GND
NC
PURPLE(VIDEO)
WHITE(AUDIO)
BLACK(power GND)
button released
the elektro-catch
RED(+12V)
DC
AUDIO
VIDEO
EGR
OV
COM
+12V
GND
Elektrozaczep rew.
lub przylepa?????????
NO
Description of clamps with connected
electro-catch reversible
Push Down
Wires
How to use clamps
in external panel
External panel
External panel
button released
the elektro-catch
MVC-7001 monitor
clamps on
backside
of panel
+ -
230V AC 15V DC/0.8A
~ ~
230V AC
+12V GNDAudio Video
red
black
purple
white
+Vcc Gnd audio video
red
black
purple
white
12V AC/1A
~ ~
EGR OV NO COM NC
* not include in the set
The
opening
button

- 7 -
Figure 7. Block diagram of connecting elements of Apus video door phone in use with
coaxial cable
BVC-6503
Electro-catch
feeder
ZS-15
J103
Electro-catch
Wiring in external panel
J102
+ -~ ~
J100
J102
ZS-15
Figure 6. Block diagram of connecting elements of Apus video door phone with additional
monitor
MVC-7001
MVC-7001
J100
Electro-catch BVC-6503
J103
Wiring in external panel
Electro-catch
feeder
ZS-15
MVC-7001
230V AC
+12V GND Audio Video
red
black
purple
white
+Vcc Gnd audio video
red
black
white
+Vcc Gnd audio video
red
black
white
+Vcc Gnd audio video
red
black
white
-
230V AC 15V DC/0.8A
+
purple
purple
purple
+ -
230V AC 15V DC/0.8A
~ ~
12V AC/1A
~ ~
+ -~ ~
EGR OV NO COM NC
EGR
+12V GND Audio Video
red
black
white
+Vcc Gnd audio video
red
black
white
purple
purple
OV NO COM NC
J100
+ -
230V AC 15V DC/0.8A
~ ~
230V AC
12V AC/1A
~ ~
+ -~ ~
EGR

- 8 -
5. ASSEMBLY AND CONNECTING ELEMENTS OF VIDEO DOOR
PHONE
Assembly and connecting MVC-7001 monitor
To facilitate the assembly, mount a standard cable box in the wall where the monitor
is to be mounted and insert the wiring of the video door phone. After the assembly, the
monitor should wholly cover the cable box. This will facilitate connecting and mounting
the monitor.
- The monitor is mounted on a metal grip screwed to the wall. To mount the grip, put it
at the wall where it is planned to be mounted and mark places for dowels.
- Drill openings in the marked places and mount the grip to the wall using the dowels.
- Connect the plugs (included in the set) for J100 and J103 sockets to the wiring in
accordance with the diagram, soldering them to the wiring. Secure the soldered places
and isolated wiring cables against short circuit using shrink wrap or insulation. Connect
the plugs to the sockets.
- Mount the monitor at the assembly jig.
Connecting an additional monitor
- In order to connect two MVC-7001 monitors to one external panel, power supply (J100
socket) should be connected in the additional monitor and the two monitors should
be connected using J102 sockets. J103 socket in the second monitor is not used. See
Figures 4 and 6.
Pin to J100 socket
(power supply)
Pin to J103 socket
Pin to J102 socket
(optional - connection
additional monitor)
Figure 8. Connectors in MVC-6502 monitor
J100
J102 J103
+Vcc
Gnd
+Vcc
Gnd
audio
video
+Vcc
Gnd
audio
video
red
black
red
black
white
violet
red
black
white
violet
Assembly and connecting the external panel BVC-6503.
- Twist off the screw mounting the panel and the wather cover.
- Put the housing in the assembly place, mark places and drill openings for dowels.
The camera lens should be located at the height of ca. 150 cm (see Figure 9a).
- Put the wire through the round opening in the housing and mount the housing to the
wall (Figure 9c).
- Connect the wires in accordance with the diagram. A cable with colour wires (see
Figures 2 and 5) is located in the external panel. Connect those wires with the wiring
of the video door phone using a soldering iron, protecting the joint with shrink wrap
or insulation.
- Put the panel to the housing and screw the assembly screws (Figure 9d).
Feeder assembly
The feeder is designed for mounting on a DIN rail. The feeder may be mounted in the
installation box with a DIN rail or on a metal grip previously screwed to the wall with
dowels (included in the set). Connect the wires in accordance with the diagram.
To ensure safety put on the mains terminal covering (plastic element attached to the
feeder) after connect the feeder to the mains.
Assembly of electro-catch
Electro-catch is controlled by a transmitter located in the external panel. The electro-

- 9 -
catch requires an additional ACV feeder. Mount the electro-catch in the gate or the door
as prescribed by the manufacturer. Then, in accordance with the diagram (Figures 5,6,7)
connect the wires (yellow and brown) in the external panel, feeder wires and electro-
catch.
6. OPERATING VIDEO DOOR PHONE
- By pushing the release button in the external panel, the doorbell signal in the monitor
will be activated and the monitor will switch on, displaying image from the camera (If
an additional monitor is mounted the doorbell signal and the image from the camera
will appear on two monitors).
- Push button (conversation - see Figure 1) to launch voice communication. In the
case of two monitors mounted, once the voice communication is launched on one
monitor, the other one switches off.
- Should the voice communication after launching fail to activate, the monitor will be
automatically switched off after ca. 1 minute.
- The conversation may last up to ca. 100s. After this time, the conversation is automatically
ended.
- To close the conversation push (conversation) button.
- It is possible to release the electro-catch at any time during the conversation by pushing
the button on the screen. The electro-catch`s transmitter operates for up to ca. 5
s. Its operation period does not depend on the length of button pushing. The electro-
catch is activated once the button is released.
- The image from the camera may be activated on the screen at any time. In order to
do so push (conversation) button. Simultaneously with activating the camera, the
voice communication is established.
- Pushing the transfer conversation button during the voice communication will transfer
the conversation to the second monitor - the first monitor switches off, and on the
second monitor the doorbell sounds and the image from the camera is shown (no audio mode).
- In order to receive the transferred conversation push (conversation) button.
- It is possible to set volume, color and brightness on the MVC-7001 monitor (see Fig.1).
CAUTION!!
Screen have delay about 2sec. first you hear a sound of doorbell.
7. MAINTENANCE
Video door phone elements should be cleaned with a damp duster. Alternatively, use
preparations for plastic elements cleaning.
ATTENTION!
Do not use preparations including solvents or abrasive materials to clean the video door
phone elements, as their use may lead to permanent damage of the housing surface!
Figure 9. Assembly of external panel View side
150cm
a) b) c) d)

- 10 -
are heard at this point then the location has a code stored, you may proceed as this
is only a warning.
4)enter the desired 4 digit user code, if the code lock retunes immediately to the
programmiong mode base level then the code is not permitted as it already exits else
where in another locations, if the code is permitted then you will hear 3 short sounds
5)return to step 2 to enter more user codes or press the * key to exit programming
mode.
ATTENTION!
In default configuration is not programmed any user code.
DELETING USER CODES
1)press *, you will hear 2 short sounds
2)enter your 4 digit administrator code, you will hear 3 short sounds, red LED is flashing
you are now in programming mode
3)enter user location (01-40), you will hear 3 short sounds
4)press button #, you will hear 3 short sounds
5)return to step 3 to delete more codes or press the * key to exit programming mode.
SETTING THE LOCK TIME
1)press *, you will hear 2 short sounds
2)enter your 4 digit administrator code, you will hear 3 short sounds, red LED is flashing
you are now in programming mode
3)enter 00, you will hear 2 short sounds
4)enter the desired lock/relay operation time in a two digit format (01 to 99 second),
you will hear 3 short sounds.
5)press the * key to exit programming mode.
ATTENTION!
Default lock time is set to 05 second.
CHANGING THE ADMINISTRATOR CODE
1)remove power from the unit and press and hold down the * key
2)apply power whilst holding button down, the unit will then give long continuous sound.
3)when the tone has stoped, release the * key and enter your new 4 digit administrator
code
Avoid letting the video door phone elements contact with water or detergents during
cleaning as it may lead to the damage of video door phone or electric shock!
8.PROGRAMMING MODE IN PANEL BVC-6503
Entering programming mode
1) press *, you will hear 2 short sounds
2)enter your 4 digit administrator code, you will hear 3 short sounds, red LED is flashing
you are now in programming mode
3) to exit programming mode press the * key.
Adding user codes
1)press *, you will hear 2 short sounds
2)enter your 4 digit administrator code, you will hear 3 short sounds, red LED is flashing
you are now in programming mode
3)enter the location 01 to 40 (31-40 are the latching code locations). If a series of bleeps

9. TECHNICAL DATA
MVC-7001 monitor
Screen size 5,8
Dimension 220x110x28
Supply voltage 15V DC/0.8A
Operation temperature 0°C...40°C
BVC-6503 external panel
Dimension 182x75x60
Operation temperature -20°C...55°C
Degree of protection IP 43
ZS-15 feeder
Input voltage 230V AC
Output voltage 15V DC/ 800 mA max.
Dimension 87x87x60
Operation temperature 0°C...40°C
Degree of protection IP 30
This product was marked with a symbol of crossed dustbin
according to European Directive 2002/96/WE on used electric
and electronic equipment. Used equipment cannot be placed
with other wastes from households. Product user is obliged to
give it to the firm which collects used electronic or electric
equipment such as local collection points, shops, places appointed
by the producer or commune waste collection units.
INSTRUCTION ON ENVIRONMENT PROTECTION
List of collecting units of used Laskomex equipment is available on www.laskomex.com.pl
website or telephone No. 42 671 88 68.
Product packing should be removed according to environment protection regulations.
Remember!
Selective collection and recycling of used electronic and electric equipment
considerably contributes to the protection of human health and life as well as
protection of natural environment.
Return of packaging materials for the material recycling saves raw materials and
reduces generating of wastes.
ver 1.0 2012-12-03
ul. D¹browskiego 249, 93-231 ³ód, tel. (0-42) 671 88 00, fax 671 88 88
Table of contents
Other Laskomex Intercom System manuals

Laskomex
Laskomex EC-2502 Owner's manual

Laskomex
Laskomex Bastion libra User instructions

Laskomex
Laskomex CD-2000 Installation manual

Laskomex
Laskomex Bastion Draco II User manual

Laskomex
Laskomex CP-2502 Series User manual

Laskomex
Laskomex CD-2000 Installation manual

Laskomex
Laskomex CD-3100 Series Installation manual

Laskomex
Laskomex Bastion Orion II User manual

Laskomex
Laskomex Bastion Apus II User manual

Laskomex
Laskomex Bastion Draco User instructions