Ledj Archi BAR 48 User manual

www.prolight.co.uk
(Order code: LEDJ222)
USER MANUAL

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOUR INITIAL START-UP!
SAFETY INSTRUCTIONS
Every person involved with the installation, operation & maintenance of this
equipment should:
- Be competent
- Follow the instructions of this manual
CAUTION! TAKE CARE USING THIS EQUIPMENT!
HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
Before your initial start-up, please make sure that there is no damage caused during
transportation. Should there be any, consult your dealer and do not use the
equipment.
To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
Please note that damages caused by user modifications to this equipment are not
subject to warranty.
ARCHI BAR 48 SAFETY
1.

ARCHI BAR 48 SAFETY
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused
by the non-observance of this manual or any unauthorised modification to the
equipment.
• Never let the power-cable come into contact with other cables. Handle the power-cable
and all mains voltage connections with particular caution!
• Never remove warning or informative labels from the equipment.
• Do not open the equipment and do not modify the equipment.
• Do not connect this equipment to a dimmer-pack.
• Do not switch the equipment on and off in short intervals, as this will reduce the
system’s life.
• Do not expose to flammable sources, liquids or gases.
• Always disconnect the power from the mains when equipment is not in use or before
cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the
power-cable.
• Make sure that the available voltage is between 220v/240v.
• Make sure that the power-cable is never crimped or damaged. Check the equipment and
the power-cable periodically.
• If the equipment is dropped or damaged, disconnect the mains power supply immediately.
Have a qualified engineer inspect the equipment before operating again.
• If your product fails to function correctly, discontinue use immediately. Pack the unit
securely (preferably in the original packing material), and return it to your Prolight dealer
for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be carried out by a qualified
technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.
• WARRANTY; One year from date of purchase.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual,
the product may suffer damage and the warranty becomes void.
Incorrect operation may lead to danger e.g.: short-circuit, burns, electric shocks,
lamp failure etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and property.
2.

Setup
Operating Instructions
The Archi Bar 48 is a DMX-512 controllable unit made up of high efficiency and Ultra Bright
RGBW LEDs and will operate in stand alone, master/slave or DMX control modes.
ARCHI BAR 48 INTRODUCTION
Introduction
Features
• DMX channels: 4/6/19 selectable
• 48 x 3W Ultra Bright RGBW LEDs (R: 12, G: 12, B: 12, W: 12)
• 14 built-in programmes
• 4 push button LCD display
• Master/Slave functions
• Auto run mode
• Power in/out connections
• DMX in/out connections
• Consumption: 84W
• Beam 25 degrees
• IP Rating: IP65
• Power supply: 240V
• Dimensions: 1000 x 120 x 175mm
• Weight: 10.2Kgs
Overview
3.
POWER
IN
DMX
IN
POWER
IN
DMX
IN
LCD DISPLAY
POWER
IN
DMX
IN
POWER
IN
DMX
IN
LCD DISPLAY

ARCHI BAR 48 OPERATION MODES
Operation modes
Dimming mode:
To activate the unit in dimming mode, press the “MODE” button to show “DIMMING” on the LCD
screen. Now press the “ENTER” button to set the brightness of the LEDs by using the “UP” and
“DOWN” buttons.
Press the “ENTER” button once for the Red LEDs, twice for Green LEDs, three for Blue LEDs
and four for the White LEDs. Each of the colours can be set from 00 - 99 by using the “UP” and
“DOWN” buttons. Press the “ENTER” button once more to select the desired flash value and
adjust by using the “UP” and “DOWN” buttons.
Brightness levels 00-99 (00 = low, 99 = high), Flash values: 00 - 99 (00 = slow, 99 = fast)
Auto run mode:
To activate the unit in auto run mode, press the “MODE” button to show “AUTO RUN” on the
LCD screen. Now press the “ENTER” button to select the desired frequency level by using the
“UP” and “DOWN” buttons.
“FQN” 01-99 (01 = low, 99 = high)
Note: In this mode, it will run 13 built-in programmes in a continious loop.
Slave mode:
To activate the unit in slave mode, first you must link multiple units together and press the
“MODE” button to show “SLAVE MODE” on the LCD screen. Now on the master unit press the
“MODE” button to select the desired mode and the slave units will now run in sequence with the
master unit.
Built-in programmes:
To activate the units built-in programmes, press the “MODE” button to show “01.DIMMING” on
the LCD screen. Press the “ENTER” button to choose between the 14 built-in programmes by
using the “UP” and “DOWN” buttons. Now press the “ENTER” button to select the desired speed
and adjust by using the “UP” and “DOWN” buttons. Press the “ENTER” button once more to
select the desired flash value and adjust by using the “UP” and “DOWN” buttons.
Speed values: 00 - 99 (00 = slow, 99 = fast), Flash values: 00 - 99 (00 = slow, 99 = fast)
For the 14 built-in programmes please see page 5.
DMX mode:
To activate the unit in DMX mode, press the “MODE” button to show “DMX MODE” on the LCD
screen. Press the “ENTER” button and select the desired DMX address setting by using the “UP”
and “DOWN” buttons. Then to select one of the 3 DMX modes 19, 6 or 4 channel,
press the “ENTER” button again to choose the desired DMX mode by using the “UP” and
“DOWN” buttons.
For the 4, 6, and 19 channel DMX address information please see pages 6 & 7.
NOTE: Once the desired settings have been selected in each of the above modes, ALWAYS
confirm the settings by pressing the “ENTER” button.
4.

ARCHI BAR 48 BUILT-IN PROGRAMME CHART
14 Built-in programme chart
4 channel mode DMX chart 6 channel mode DMX chart
5.
01. Dimming
Blackout - Full on
Flash 00 - 99
Red: 00-99, Green: 00-99, Blue: 00-99, White: 00-99
Flash adjustable
02. Colour Jump
Speed 00 - 99, Flash 00 - 99
7 colour change
Speed & Flash adjustable
03. Colour Fade
Speed 00 - 99, Flash 00 - 99
7 colour fade in, fade out
Speed & Flash adjustable
04. Dream
Speed 00 - 99, Flash 00 - 99
7 colour fade
Speed & Flash adjustable
05. Colour Flow
Speed 00 - 99, Flash 00 - 99
7 colour chase (forward & reverse)
Speed & Flash adjustable
06. Over Flow
Speed 00 - 99, Flash 00 - 99
7 colour chase in relay pattern (forward & reverse)
Speed & Flash adjustable
07. Colour Chase
Speed 00 - 99, Flash 00 - 99
7 colour chase (forward)
Speed & Flash adjustable
08. Multi-colour
Speed 00 - 99, Flash 00 - 99
Multi-colour relay chase
Speed & Flash adjustable
09. Fade Flow
Speed 00 - 99, Flash 00 - 99
7 colour fade relay chase
Speed & Flash adjustable
10. Two Flow
Speed 00 - 99, Flash 00 - 99
2 colour relay chase
Speed & Flash adjustable
11. One Way
Speed 00 - 99, Flash 00 - 99
7 colour relay chase
Speed & Flash adjustable
12. Two Way
Speed 00 - 99, Flash 00 - 99
7 colour relay chase (criss cross)
Speed & Flash adjustable
13. Two colour
Speed 00 - 99, Flash 00 - 99
7 multi-colour relay chase (criss cross)
Speed & Flash adjustable
CH4
W
0-255
CH1
R
0-255
CH2
G
0-255
CH3
B
0-255
CH4
W
0-255
CH1
R
0-255
CH2
G
0-255
CH3
B
0-255
CH5
Master
Dimmer
0-255
CH6
0-10 - On
11-255 - Flash

ARCHI BAR 48 DMX PROGRAMME CHARTS
19 channel mode DMX chart
6.
CH4CH1 CH2 CH3 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15
0-5
black
out
6-10
dimmer
11-15
dimmer
16-20
Red
21-25
Green
26-30
Blue
31-35
White
36-40
R/W
41-45
R/G
46-50
R/B
51-55
G/B
56-60
W/B
61-65
W/G
66-70
R/G/B
71-75
R/G/W
76-80
R/B/W
81-85
G/B/W
86-90
R/G/B/W
91-100
R/G/B/W
Dimmer
0-255
Flash
0-255
R
0-255
G
0-255
B
0-255
W
0-255
R1
0-255
G1
0-255
B1
0-255
W1
0-255
R2
0-255
G2
0-255
B2
0-255
W2
0-255
R3
0-255
G3
0-255
B3
0-255
W3
0-255
Speed
0-255
Flash
0-255
101-110
Colour jump
111-120
Dream
121-130
Colour flow
131-140
Over Lap
flow
141-150
Colour
chase
151-160
Multi-colour
161-170
Fade flow
171-180
Two flow
181-190
One way
191-200
Two way
201-210
Two colour
211-255
N/A
CH16 CH17 CH18 CH19
R4
0-255
G4
0-255
B4
0-255
W4
0-255
11-15
dimmer
CH1
Dimmer
0-255
Flash
0-255
CH2 CH3

ARCHI BAR 48 DMX SET UP
DMX-512:
• DMX (Digital Multiplex) is a universal protocol used as a form of communication between
intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the
controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the
DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only
have a data “out” terminal).
DMX Linking:
• DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX fixtures try to use the
shortest cable path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be
placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a
fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to
address 1 to that unit, no matter where it is located in the DMX chain.
DATA Cable (DMX cable) requirements (for DMX operation):
• The Archi Bar 48 can be controlled via DMX-512 protocol. The DMX address is set on the
back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for
data input/output (figure 1).
Figure 1
Also remember that DMX cable must be daisy chained and cannot be split.
Further DMX cables can be purchased
from all good sound and lighting suppliers
or Prolight dealers.
Please quote:
CABL10 – 2M
CABL11 – 5M
CABL12 – 10M
7.

Notice:
• Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable’s shield
conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer
casing. Grounding the shield could cause a short circuit and erratic behaviour.
Special Note: Line termination:
• When longer runs of cable are used, you may need to use a terminator on the last unit to
avoid erratic behaviour.
Using a cable terminator (part number CABL90) will decrease the possibilities of erratic
behaviour.
5-Pin XLR DMX Connectors:
• Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin
XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin
XLR connectors in to a 3-pin line a cable adaptor must be used. The chart below details the
correct cable conversion.
Termination reduces signal transmission problems
and interferance. it is always advisable to connect a
DMX terminal, (resistance 120 Ohm 1/4 W) between
pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.
ARCHI BAR 48 DMX SET UP
8.

ARCHI BAR 48 TECHNICAL SPECIFICATIONS
Technical Specifications
Weight & Dimensions
• Length…............................................................1000mm
• Width..................................................................120mm
• Height……………………………………………...175mm
• Weight………………………………………..........10.2sKgs
Power
• AC input……………………………………..........240V/50hz
• Power consumption.........................................84W
• Fuse
• Main………………………………………………...F2A
Control & Programming
• Data input………………………………………....Locking 3-pin XLR male socket
• Data output………………………………………..Locking 3-pin XLR female socket
• Protocols………………………………………….DMX-512 USITT
• DMX channels…………………………………....19, 6 and 4
9.

10.

www.prolight.co.uk
Table of contents
Other Ledj Lighting Equipment manuals

Ledj
Ledj Stage Wash 18 User manual

Ledj
Ledj FLEX30 User manual

Ledj
Ledj LEDJ112 User manual

Ledj
Ledj LEDJ472 User manual

Ledj
Ledj ALU ZOOM PAR 64 User manual

Ledj
Ledj Spectra Q40 MKII User manual

Ledj
Ledj RGB DMX User manual

Ledj
Ledj Slimline 3HEX12 Series User manual

Ledj
Ledj STAGE CLOUR QUAD User manual

Ledj
Ledj Artisan 1000 User manual

Ledj
Ledj Xterior Wash Tri User manual

Ledj
Ledj STAGE BAR 16 User manual

Ledj
Ledj Event Panel User manual

Ledj
Ledj Spectra Par 15Q8 PRO User manual

Ledj
Ledj Spectra QX40 Pixel MKII Exterior Fixture User manual

Ledj
Ledj LEDJ24 User manual

Ledj
Ledj Slimline CW Series User manual

Ledj
Ledj LEDJ255 User manual

Ledj
Ledj LEDJ266 User manual

Ledj
Ledj FS300 User manual