Measurement Preparations Sprinter 150/150M/250M - 1.0.0en
EN
DE
FR
ES
NO
SV
FI
DA
IT
PT
NL
Accessories
Tripod, aluminum staff (region dependant), fibre glass staff (to 
achieve 0.7 mm accuracy with Sprinter 250M). (Optional: 
sunshade, 4 rechargeable batteries and charger)
3. Measurement Preparations
3.1 Change Battery
Insert 4 AA dry cells according to the positive and negative signs as 
indicated on the holder. 
)Always replace with a complete battery set!
)Do not use old and new batteries together.
)Do not use batteries from different manufacturers or 
batteries of different types.
3.2 Set-up Instrument
Levelling
• Set up the tripod. Extend the legs to a suitable length and ensure 
that the tripod head is approximately level. Tread the tripod 
shoes firmly into the ground to ensure stability. 
• Mount the instrument on the tripod by screwing the tripod screw 
onto the base of the instrument. 
• Use the three levelling foot screws to center the circular bubble 
in order to level the instrument.
Eyepiece Adjustment
Point the telescope to a uniform light surface such as a wall or a 
piece of paper. Turn the eyepiece until the cross hairs are sharp or 
distinct.
Target Image Focusing
Use the gunsight to aim the objective lens at the staff. Turn the hori-
zontal fine motion screw until the staff is nearly centered in the field 
of view and then turn the focusing knob to focus on the staff. Ensure 
that staff image and reticle are sharp or distinct.
Power ON
The instrument is ready to measure.
)Technical hints: 
• First check and adjust the electronic and optical line-of-sight 
errors, then the circular level on the instrument and then the staff: 
before starting work in the field, after long storage periods, after 
long transportation. 
• Keep the optics clean. Dirt or condensation on the optics can 
limit measurements. 
• Before starting work, let the instrument adjust to the ambient 
temperature (approx. 2 minutes per °C of temperature differ-
ence). 
• Avoid measuring through window panes. 
• Staff sections have to be fully extended and properly secured. 
• Touching the upper third of the tripod, can damp vibrations at the 
instrument due to wind. 
• Use the lens hood to cover the objective when backlightdisturbs. 
• Evenly illuminate the measuring area of the staff with a flashlight 
or spotlight in darkness.