The T1kVA and T1.5kVA Tower Uninterruptible Power Supply (UPS) offerings provide power protection
with increased efficiency and simplified power management to safeguard the high-availability of Lenovo
server environments. With efficiency ratings of up to 97%, these compact tower designs can help reduce
energy usage without compromising performance or reliability.
The Tower UPS unit (T1kVA or T1.5kVA) is shown in Figure 1.
Figure 1. Tower UPS unit (T1kVA or T1.5kVA)
Did you know?
T1kVA and T1.5kVA Tower UPS units feature Advanced Battery Management (ABM) technology that uses
a unique three-stage charging technique that significantly extends battery service life and optimizes
recharge time, compared to traditional charging.
T1kVA and T1.5kVA Tower UPS units can enhance system availability with individual receptacle groups or
load segments that can be programmed and controlled, which allows mission-critical devices to be
prioritized during shutdown to preserve battery run time if there is a prolonged power outage.
T1kVA and T1.5kVA Tower UPS units come standard with UPS Power Manager (UPM) power management
software that integrates seamlessly with the major virtual platforms, which enables you to view and
manage your entire power system from your current dashboard. It also triggers live migration during power
outages and avoids data loss by gracefully shutting down virtual machines and hosts in a cluster if there is
an extended power outage.
T1kVA and T1.5kVA Tower Uninterruptible Power Supplies 1

Ordering information
Table 1 shows the part numbers and feature codes for the T1kVA and T1.5kVA Tower UPS models and
options.
Table 1. Ordering part numbers and feature codes
Description Part number Feature code
UPS units
T1kVA Tower UPS (100-125VAC) 55951AX A548 (5595-TU1)
T1kVA Tower UPS (200-240VAC) 55951KX A549 (5595-TU1)
T1.5kVA Tower UPS (100-125VAC) 55952AX A54A (5595-TU2)
T1.5kVA Tower UPS (200-240VAC) 55952KX A54C (5595-TU2)
Options
UPS Network Management Card 46M4110 6145
Environmental Monitoring Probe 46M4113 6146
The UPS models ship the following items:
An accessory kit, which contains the following items:
Serial cable: 1.2 m (4 ft)
USB cable
Remote emergency power-off (REPO) connector
A documentation kit, which contains the following items:
Documentation package
Software CD, which contains UPM software
The 100 - 125 V models (1AX and 2AX) ship with fixed 1.8 m NEMA 5-15P line cord. The 200 - 240 V
models (1KX and 2KX) do not ship with line cords. Table 2 lists the compatible line cords, which are
suitable for models 1KX and 2KX.
T1kVA and T1.5kVA Tower Uninterruptible Power Supplies 2

Table 2. Line cords for 200 - 240 V models (models 1KX and 2KX)
Description Part number Feature code
10A/250V C13 to NEMA 6-15P 2.8m line cord 46M2592 A1RF
Argentina 10A line C13 to IRAM 2063 (2.8M) 39Y7930 6222
Australia/NZ 10A line C13 to SAA-AS C112 (2.8M) 39Y7924 6211
Brazil 10A line C13 to NBR 6147 (2.8M) 39Y7929 6223
China 6A line C13 to GB 2099.1 (2.8M) 39Y7928 6210
Denmark 10A line C13 to DK2-5A (2.8M) 39Y7918 6213
European 10A line C13 to CEE 7/7 (2.8M) 39Y7917 6212
India 6A line C13 to Fig 68 (2.8M) 39Y7927 6269
Israel 10A line C13 to SI 32 (2.8M) 39Y7920 6218
Italy 10A line C13 to CEE 7/7 (2.8M) 39Y7921 6217
Japan 10A line C13 to JIS C-8303 (2.8M) 46M2593 A1RE
Korea 7A line C13 to KETI 15A/250V (2.8M) 39Y7925 6219
South Africa 10A line C13 to SABS 164/1 (2.8M) 39Y7922 6214
Switzerland 10A line C13 to SEV 1011 (2.8M) 39Y7919 6216
Taiwan 10A/250V C13/CNS 10917 2.8m line cord 81Y2375 A0RF
United Kingdom 10A line C13 to BS 1363 (2.8M) 39Y7923 6215
The T1kVA and T1.5kVA Tower UPS models also come equipped with a communication bay for the
installation of an optional Network Management Card (46M4110). The Network Management Card (NMC)
provides convenient, over-the-network UPS remote monitoring and management through a standard web
browser or UPM software. The following figure shows the UPS NMC.
Figure 2. UPS Network Management Card
The NMC has the following features:
Versatile connectivity through HTTP, SNMP, SMTP, Telnet, SSL, and SSH
Simultaneous shutdown of protected servers
Configuration of automatic email messages in response to UPS alarms and to transmit periodic
reports
Customizable actions, including automatic shutdown if there is an extended power failure with
standard UPS Power Protector software
Control of UPS on/off switching with a web browser
Adjustment and control of load segments through the HTML interface, including sequential starting
of the installation and optimization of backup time by shutting down non-priority systems
Automatic date and time adjustment through an NTP server
T1kVA and T1.5kVA Tower Uninterruptible Power Supplies 3

Dual stack IP v4/IP v6
Recording of events and measurements in the card log
Data and event logging in the nonvolatile memory
Card firmware update through the network
10/100 Mb Ethernet (RJ-45 connector) with auto-negotiation
Measurement of humidity and temperature with the optional Environmental Monitoring Probe (EMP)
Easy installation (can be installed while the UPS is online to maintain the highest system availability)
An optional EMP (part number 46M4113) is used to report local temperature and humidity values and make
that information available to management tools. The EMP connects to the UPS via the NMC. The EMP is
shown in the following figure.
Figure 3. Environmental Monitoring Probe
The EMP has the following features:
Monitors temperature, humidity, and status of two user-provided contact devices or sensors
Connects to an NMC through an RJ-45 CAT5 Ethernet cable (1 m cable included with the EMP)
Can be located up to 20 m (65.6 ft) from the UPS
Measures ambient temperatures 0 - 80 °C (32 - 176 °F) with an accuracy of ±1 °C
Measures relative humidity 10 - 90% with an accuracy of ±5%
Displays temperature, humidity, and contact closure status through a web browser
Supports user-defined alarm thresholds for temperature, humidity, and contact closure status
Stores events in the NMC's event log
Sends SNMP alarms to network management systems
Sends e-mail notifications through SMTP
Features
T1kVA and T1.5kVA Tower Uninterruptible Power Supplies 4

Features
A UPS is a device that acts as a defensive barrier between electronic equipment and incoming power
problems. It conditions, regulates, and filters out power disturbances to ensure a clean power source for IT
equipment. A UPS also provides battery backup if there is a power failure.
In today’s high availability server environments, unplanned power outages or line quality irregularities can
have a considerable financial effect on all sized businesses. The typical utility power is 99.9% available, but
that means that there can be almost 9 hours of downtime a year, which includes brownouts and other
power quality problems.
Selecting the right UPS can help protect against these potentially costly incidents.
The T1kVA and T1.5kVA Tower UPS units are most effective against five power problems: power failures,
power sags, power surges, under-voltage, and over-voltage.
The T1kVA and T1.5kVA Tower UPS models offer the following features:
High-efficiency protection delivers more real power (watts) in a compact design, lowering power,
and cooling consumption
Graphical Liquid Crystal Display (LCD) provides intuitive configuration, management, and monitoring
capabilities in the following languages to reduce management complexity:
English
French
German
Spanish
Russian
Portuguese
Italian
Hot-swappable batteries for maximum uptime, availability, and ease of maintenance
Standard UPS Power Manager software provides effective local or remote power monitoring and
management for servers and virtual machines and allows for graceful remote system shutdown
ABM technology significantly extends battery service life and optimizes recharge time
Load segments for individual control of receptacle groups to manage sequential shut downs and
start ups and reserve battery run time for the most critical equipment
Optional NMC for enhanced UPS monitoring and control over-the-network through a standard web
browser
Optional Environmental Monitoring Probe for thermal management requirements (temperature and
humidity)
Allows dual channel communication through the USB or RS-232 port and an optional NMC at the
same time to maximize communications flexibility
Remote flash upgradeable firmware for the UPS and NMC, which makes it an ideal solution for
remote locations
Includes a Remote On/Off (ROO)/Remote Power Off (RPO) port to control power of the UPS unit
through a wired remote switch
T1kVA and T1.5kVA Tower Uninterruptible Power Supplies 5
This manual suits for next models
1
Table of contents
Other Lenovo UPS manuals

Lenovo
Lenovo 55948KX Operating instructions

Lenovo
Lenovo RT8.0kVA User manual

Lenovo
Lenovo IBM UPS5000 User manual

Lenovo
Lenovo 5594-6KX User manual

Lenovo
Lenovo RT5.0kVA User manual

Lenovo
Lenovo Smart 750XLa User manual

Lenovo
Lenovo RT1.5kVA User manual

Lenovo
Lenovo RT8.0kVA User manual

Lenovo
Lenovo RT1.5kVA User manual

Lenovo
Lenovo 55948KX User manual