Leviton GreenMAX R16TC-100 User manual

GreenMAX Relay System Cabinet
Cat. Nos. R16TC-100, R32TC-100, R48TC-100
For use with GreenMAX Relay Systems
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• Installation and maintenance of this unit and the associated components requires an electrician.
• All relays must be installed on a Relay Insert Panel in a Leviton GreenMAX Relay Systems cabinet.
• The covers and lower ventilation plate must be in place when any circuit in the cabinet is energized.
INSTALLATION English
PK-93838-10-00-0A-X2
To Install
MOUNT CABINET
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND
TEST THAT THE POWER IS OFF BEFORE WIRING!
2. Securely mount enclosure to wall using fasteners appropriate for wall type.
NOTE: Mounting holes are provided in the enclosure, the upper holes are keyhole slots to facilitate easy hanging.
Any field drilled mounting holes should be confined to the wire-way areas so that they do not obstruct the
installation of the Relay Insert Panels or the Command Module.
3. Install all conduit runs and pull all lighting circuit and power wiring.
NOTE: It is recommended that all wire be pulled prior to installing the Command Module and Relay Insert Panels.
This will prevent damage to the electrical components.
INSTALL COMMAND MODULE
1. Install the Command Module by sliding the slots on the bottom of the Command Module over the mounting tabs
of the cabinet. Pass the Power Supply leads through the grommet to the power wiring area while installing. The
Command Module should be free to rotate forward and back without any obstruction. Fasten the Command
Module in place with the two screws provided (see Detail on page 2).
2. Connect the incoming Line, Neutral, and Ground wires of the designated power circuit, to the cabinet electronics.
NOTE: This connection should be made in the power wiring area provided. If the source of power requires that
this area must be separated from other circuit conductors, install the metal partitions provided. The Neutral
connection must also include the Neutral wire from the uppermost Relay Insert Panel. A jumper is provided to
extend this conductor from the Relay distribution spine to the connection point.
3. Connect the Equipment Grounding conductor to the grounding location provided adjacent to the system power
supply. Use the ground screw provided for this purpose.
4. Using Cat 5 (or better) cables and RJ45 connectors, connect the Power Supply to both the MPU and the Low
Voltage input board using the designated ports.
NOTE: If Low Voltage inputs are required, make these connections according to the diagrams provided for the
specific input type. To aid this process, remove the terminal blocks by pulling the green block straight out and
away from the module. Provide enough cable length to allow the unobstructed movement of the Command
Module.
INSTALL RELAY INSERT PANEL
1. Position Relay Insert Panel on the locating tabs of the cabinet and fasten in place with the two mounting screws
provided at the top of the panel. Plug the ribbon cable into the Command Module. The Neutral jumper must be
extended to make a connection with the Power Supply neutral and the panel feed.
2. Connect Line and Load to the relays according to the panel schedule provided in the document package.
NOTE: Relay line and load terminals are suitable for wire sizes #6 to #14 AWG Copper solid or stranded.
Stranded wire should be tightly twisted before insertion into terminal.
WIRE LOW VOLTAGE INPUT CARD
1. Wire Low Voltage wiring according to the device wiring diagrams.
NOTE: Low Voltage wiring should be confined to the designated areas at the top of the enclosure. LumaCAN
wiring is interconnected with Cat5 (or better) cable and RJ45 connectors. All cables should be tested and verified
for proper operation before being connected to any components.
NOTE: Areas at the top left and right corners of the enclosure can be used for either Low Voltage or High Voltage
wiring. Metal barriers are provided to segregate Lighting/ Power Wiring and Low Voltage wiring. These barriers
can be relocated as necessary.
NOTE: Low voltage wire should be #14 - #24 AWG.
RATINGS:
• Forrelayratings,seetheInstallationSheetprovidedwitheithertheRelayInsertPanelsortheIndividualrelay.
•The power requirement of the Command Module is: 100-277VAC 50/60Hz
• TheloadratingofthePowerSupplyoftheCommandModuleis:70W@24VDC+/-10%
• ThiscomponentissuitableforNEMA1applicationsonly(indooruse/notwaterorweatherresistant).
3. To test circuit, turn circuit breaker OFF, use the manual actuator handle to turn the relay to the Closed or ON
position and then turn circuit Breaker ON. This prevents damage to the relay if the circuit is shorted.
NOTE: Individual relays can be relocated or added by aligning and inserting tabs on the base of the relay in the
slots provided in the back-plate. While inserted, slide the relay toward the center until completely engaged.
Relay Insert Panels
Cat Number:
R1600-000 R1616-1DS
R1616-1CB R1616-2CB
R1616-1CS R1616-2CS
R1616-1TB R1616-2TB (SHOWN)
R1616-1TS R1616-2TS
Enclosure
Cat Number:
R16TC-100
R32TC-100
R48TC-100 (SHOWN)
Multi-use Areas
Removable
barriers partition
this area to
meet field
requirements.
Mounting holes
Quantity of
holes provided
depends on
length of cabinet.
Upper holes
are slotted to
ease installation.
Additonal holes
may be added
in the wireway
area only. Avoid
areas reserved
for the Relay
Insert Panels and
the Command
Module.
Conduit Entry
Conduits can
enter the cabinet
on all four (4)
sides. Plan for
Low Voltage
conductors at
the top of the
enclosure.
Low Voltage Area
Relay Insert Panel Mounting Tab
Line Terminals Phase 1
Phase 2
Load Terminals
Manual Actuator
Command Module
Cat Number:
RPM00-100
RPM08-108
RPM16-116 (SHOWN)
Lighting & Power Wireway
Lighting & Power Wireway
Wireway
Hook Detail
Left Cover Enclosure
INSTALL COVERS AND DOORS
NOTE: The Cover and Door assembly consists of four components; lower vent plate, left cover, right cover,
and the door.
NOTE: The covers and lower vent plate must be in place when any circuit in the cabinet is energized.
1. To install the left and right covers, start a mounting screw in the second from the bottom screw hole on the
cabinet flange. Do not completely tighten screw but leave enough space for the thickness of the cover. Locate
the upper mounting hook on the cover and the corresponding tab on the enclosure. Locate the keyhole slot at
the second from the bottom location. Align both the hook and the keyhole slot with their mating features of
the cabinet and slide in place. See Hook Detail.
2. Install all mounting screws provided to permanently fasten the covers in place.
3. Install the lower ventilation panel by sliding mating tabs of the left and right covers through the slots provided
in the ventilation plate. Lower the ventilation plate into place and fasten with mounting screws.
4. Install the door by sliding the halves of the hinges together. Hang the door on one hinge pin at a time, the pins
are different lengths to facilitate easy assembly.
LIMITED 10 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ten years from the purchase date. Leviton’s only obligation is to correct such defects by repair or
replacement, at its option, if within such ten year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Mfg. Co., Inc. 201 North Service Road, Melville, N.Y. 11747, U.S.A.This warranty excludes and there is disclaimed liability for labor for removal of this product
or reinstallation.This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of
any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to ten years.Leviton is not liable for incidental,indirect,
special, or consequential damages, including without limitation,damage to,or loss of use of, any equipment,lost sales or profits or delay or failure to perform this warranty obligation.The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call: 1-800-959-6004 (U.S.A. Only)
www.leviton.com
COMMAND MODULE DETAIL
Power Supply
Ground power
supply here MPU
Feed wires
through hole Mounting Tabs
DIP Switch
Low Voltage
Input Card
16 Inputs shown
LumCan Ports
4 LumCan Ports
DIP Switch
Hinge
32 Relay Cabinet48 Relay Cabinet 16 Relay Cabinet
Lower
Vent
Plate
Keyhole
Slot &
Temporary
Mounting
Screw
Right
Cover
Left
Cover
Lock
Door
DIP SWITCH SETTINGS
Set the ID Address of the Command Module and Low Voltage
Input Card - Examples shown below
ID 1 ID 2 ID 3 ID 4 ID 5 ID 6 ID 38 ID 86
1
2
4
8
16
32
64
128
O N
1 2 3 4 5 6 7 8
O N
1 2 3 4 5 6 7 8
O N
1 2 3 4 5 6 7 8
O N
1 2 3 4 5 6 7 8
O N
1 2 3 4 5 6 7 8
O N
1 2 3 4 5 6 7 8
O N
1 2 3 4 5 6 7 8
O N
1 2 3 4 5 6 7 8
ID Address Value = Sum of Switch Values
ID86=2+4+16+64
Switch
Values
PK-93838-10-00-0A-X2© 2010 Leviton Mfg. Co., Inc.
64"
48"
31-1/2"

This manual suits for next models

2

Other Leviton Relay manuals

Leviton EZ-MAX Plus 8 User manual

Leviton

Leviton EZ-MAX Plus 8 User manual

Leviton Z-Max Remote Installation and operating instructions

Leviton

Leviton Z-Max Remote Installation and operating instructions

Leviton 40A00-1 Mounting instructions

Leviton

Leviton 40A00-1 Mounting instructions

Leviton EnOcean WSPAS-LV4 User manual

Leviton

Leviton EnOcean WSPAS-LV4 User manual

Leviton GreenMAX Relay System Cabinet User manual

Leviton

Leviton GreenMAX Relay System Cabinet User manual

Leviton GreenMAX RELAY-1TB User manual

Leviton

Leviton GreenMAX RELAY-1TB User manual

Leviton EZ-MAX Plus 16 User manual

Leviton

Leviton EZ-MAX Plus 16 User manual

Leviton EZ-MAX User manual

Leviton

Leviton EZ-MAX User manual

Leviton EZ-MAX H Series User manual

Leviton

Leviton EZ-MAX H Series User manual

Leviton EZ-Max Plus Operating instructions

Leviton

Leviton EZ-Max Plus Operating instructions

Leviton WSP05-010 User manual

Leviton

Leviton WSP05-010 User manual

Leviton GreenMAX Series User manual

Leviton

Leviton GreenMAX Series User manual

Leviton GreenMAX R1616-1CB User manual

Leviton

Leviton GreenMAX R1616-1CB User manual

Leviton Z-MAX r24sd User manual

Leviton

Leviton Z-MAX r24sd User manual

Leviton GreenMAX R16TC-100 User manual

Leviton

Leviton GreenMAX R16TC-100 User manual

Leviton EZ-Max Plus Operating instructions

Leviton

Leviton EZ-Max Plus Operating instructions

Popular Relay manuals by other brands

Seg MRP2 manual

Seg

Seg MRP2 manual

PickData SEM One manual

PickData

PickData SEM One manual

GE SBC23A instructions

GE

GE SBC23A instructions

Ampcontrol EFL user manual

Ampcontrol

Ampcontrol EFL user manual

GST DI-9302E manual

GST

GST DI-9302E manual

DEEsys DFR-021D manual

DEEsys

DEEsys DFR-021D manual

Berker 2912 quick start guide

Berker

Berker 2912 quick start guide

Chenzhu CZSR8001-3A1B user manual

Chenzhu

Chenzhu CZSR8001-3A1B user manual

Rockwell Automation Guardmaster Allen-Bradley 440R-S35001 Reference manual

Rockwell Automation

Rockwell Automation Guardmaster Allen-Bradley 440R-S35001 Reference manual

CD Automation REVO S IFH 1PH user manual

CD Automation

CD Automation REVO S IFH 1PH user manual

KUSSMAUL 091-100-012 installation instructions

KUSSMAUL

KUSSMAUL 091-100-012 installation instructions

Siemens SIRIUS 3RQ1 Original operating instructions

Siemens

Siemens SIRIUS 3RQ1 Original operating instructions

Sel SEL-787 instruction manual

Sel

Sel SEL-787 instruction manual

Minebea MIS-304-P Mounting instruction

Minebea

Minebea MIS-304-P Mounting instruction

Mitsubishi Electric CBV2-A01D1 instruction manual

Mitsubishi Electric

Mitsubishi Electric CBV2-A01D1 instruction manual

Siemens Sirius 3UG4621 operating instructions

Siemens

Siemens Sirius 3UG4621 operating instructions

Vemer CLIP-485 user manual

Vemer

Vemer CLIP-485 user manual

GE 750 instruction manual

GE

GE 750 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.