Lexing lx-hs06 User manual

Homesecurityalarm systemLX-HS06
Instruction
Briefintroduction
LX-HS06isasetofentirelynewEnglishhomesecurityalarmsystem,ituses
advancedMCU controland SMDtechnology.itinnovatemultipletradenewtechnique.It
hasintegrationhigh,reliabilitygood,technologyadvanced,functionmightiness and
operation simpleetc.feature.Itusedabroad inbank,organ,enterprise,army,villaDom,
and small zonehousing networkalarm.
Technicalparameter
TheMain:
Power:12VDC(poweradapterconvert)
Standbypower: DC12V(chargeablebattery)
Working frequency: 433MHz 315MHz
Remotecontroldistance:≥30m
Staticcurrent: 150mA
Batterygroup waiting time: 90min
Factorysetting:
Systempassword:000000 Systemdelay:0sec
Userpassword: 1234 Alert: 300sec
Code: 0000 Dialtimes: 3
Report: no reportVibrant ring times: 8
SensoremitterLX-AL8:
Working power: DC9V(cascading battery)Staticcurrent: 30μA
Sensedistance: 12mSenseangle:110°
Installing height:2m
4-keyremotecontroller: Working power: DC3V(lithiumbattery)
Single-keyremotecontroller: Working power: DC12VA23 battery
Doormagnetism(LX-DM1): Working power: DC12VA23 battery
Siren: powerDC12V, current: <800mA
Basisconfiguration
Optionunit
Smokealarm(LX98-RF LX728-RF) wiredsensor(glassbreakLX-AL5、PIRLX-AL6, PIR&glassbreakLX-AL7,doubledetectors
PIRLX-AL11)、wiredorwireless PIRLX-AL9!
Function
n 4+8 armzone
LX-HS06 has4wiredarmzonesand 8wireless armzones.
n Englishdisplay
Itsoperation and setting all bedisplayedbyEnglishand operation ismoreconvenient and shortcut.
n Function mightiness
Possessing multipleprogrammablefunction setting, operation and setting issimple, standbypowerfor24 hours.
n Onekeyoperation
You needonlypress [AWAY]or[HOME]keytosetarm/stay,you can alsouseremotecontrollertoarm/disarm.Underany
statedisarming needonlypressing userpassword.
n Numeral speech
Innersetnumeralspeechware,andhas8sectionnumeralspeeches.Duringoperation,itprompt: Systemarm , “system
disarm ;during alarming,itcanidentifydetectorautomaticallyand transmitalarminfotoreceivingalarmtelephone,like “fire
alarm , “gasalarm , “securityalarm , “helpalarm .
n Passwordpopedom
Ithas[systempassword]and [userpassword],thetwopasswordscanbesetafterentering alarmsystembutrespective
function popedomisdifferent, that isconvenient formanagerand operatortocontrolalarmsystemreligiously.
n Long-distance remotecontrol
Thealarmcan becontrolledbykeypad andremotecontroller,bytelephoneline,itcan belong-distancecontrolled,and fulfill
arm/disarm/monitorhearing function.
themain(DC12Vstoragebatterygroup include)1pcs
Poweradapter
(Input 230VAC,output 12VDC,current 1000mA) 1pcs
4-keyremotecontroller(batteryinclude)2pcs
single-keyremotecontroller(batteryinclude)1pcs
SensoremitterLX-AL8(batteryinclude)1pcs
DoormagnetismLX-DM1(batteryinclude)2pcs
Siren1pcs
Telephoneline 1pcs

n Intelligentstudy.
Wireless detectorstudyisverysimple.Thestudytimeneedno 1sec.
Connectionline
1. connect phoneline: connect themaintoworkablephonepath. NOTE: if not connect phoneline, themainwill give"path
trouble"prompt.
2. Connect poweradapter: theadapterrequires: input 230VAC, output 12VDC, and current 1000mA. During ACpowerison,
standbybatterywill bechargedautomatically. WhenACpowercut off, theproduct works bystandbybatteryentirely.
3. conncetion terminal:
·poweroutput terminal[terminal1(+)、2(-)]
output DC12Vpower, can powersupplyforLX-AL6.
·sirenterminal[terminal3(-)、 4 ( + ) ]
sirenpower:DC12V, current:800mA
·detectorsignalterminal[terminal5(6,7,8)、 GND(2,3)]
themainhas 4wiredarmzone:[5-GND]is01 zone;[6-GND]is02zone;[7-GND]is03zone;[8-GND]is04 zone.
Functionsetting
enterprogramming
Themain’ssystempasswordis[000000],allsettingsand modifying
ofthemainmustbedoneviasystempassword.Theuserpasswordis
[1234].
Attention:thesystempasswordisthehighestgrade;onlyviaityou
can modifytheuserpasswordandall specificationof themain.Sowhen
you modifythesystempassword,you mustrememberthenew
passwordfirmly.
Afterconnectionlineright,switchon power,thePOWERledlight;
whenthemainisinarmstateorguardst,theARMledlight. LCD display
themain’sstate(“ArmSt or “GuardSt or “DisarmSt ),that indicateit isnormal.
Attention:whenLCDdisplay “ArmSt or “GuardSt , ifyou needtoprogram,youneedtoinput userpasswordtodisarmthe
main, whenLCD display “DisarmSt , you can start toprogram.
Whenthemainisindisarmstate(disarmst), press the SETkeyon keypad,LCDdisplay<inputlevel>andremindyou input
thesystempassword, press #keytoenterthemainmenu.
POWER
ARM
ABC 0 #
8TUV 9WXYZ
4GHI 5JKL 6MNO
3DEF2ABC1AWAY
HOME
SET
MEDICAL FIRE HELP
7PQRS
Disarm St
Input level
******
1.Sys 2.Zone
3.Setup 4.Study
siren
controllerinnerPCB
phone line
13O N P U L SE
L E D O F F
-4
-6
0
4
2
-2
TAMPER
+
_RELAY
LX-AL6 innerPCB
_12VDC+
poweroutput
poweradapter
TAMPER RELAY

1.Level
2.Code
3.Report
4.Delay
01
02
03
04
05
…
12
1. Instant
2.Delay(zone)
3.24 HR
4.Bypass
1. Alert
2.Home
3.Call
4.Delhome
1.Tele1
2.Tele2
3.Tele3
4.Tele4
functionmenu
Armstate
1. Sys
2. Zone
Disarmstate
3. Setup
4. Study
Guardstate
NOTE:whenprogramming, the[*]keyisforreturning topreviousmenu, and [#]keyisforconfirming.
•
systemsetting1.sys
—Passwordmodifying 1. level
1> modifysystempassword<sys level>
entermenu 1.level→1.syslevel→LCD display “inputsys level ,input6-bitpasswordand press #keytoconfirm. Thesystemsave
onlythelast password, pleaseremembernewpasswordfirmly!
2> modifyuserpassword<userlevel>
entermenu 1.level→2.userlevel→LCD display “inputuserlevel ,input4-bitpasswordandpress #keytoconfirm.Thesystem
saveonlythelast password, pleaseremembernewpasswordfirmly!
—codesetting<centernetworkcode>2. codeno thesetting temporarily.
—report setting3.report
Entermenu 3.report→LCD display:
Selecting 1isreport tocenter, selecting 2isno report.
Attention: whenneedsaving telephoneexpenseorthealarmneedn’t benetwork, you can not set it.
1.Armreport
2.No report
1.Smoke
2.Gas
3.Panic
1.Tel
2.Dial
3.Vibrantring
1.Remote
2.Armzone
3.Del
Wired
Wireless
1.Sys level
2.User level
Inputsyslevel
******
Input user level
****
1.Arm report
2.No report
1.level 2. code
3.report 4.delay
1.Sys 2.Zone
3.Setup 4.Study
Press 1

—delay<systemdelay>4.delay
Entermenu 4. relay→LCD display:
Afterinputting press #keytoconfirm.** isdelaytimeforawayhomewhenarming, it can set to00~99sec.
arm zonesetting 2.zone
Entermenu 2. zone→LCD display:
**is01~12armzone,afterinputtingpress#keytoconfirm,and thenaccordingtoyourneedselect[instant], [delay], [24 hours],
[bypass] armzonetype.
When select[1.instant],afteritreceivesignal,themainwill dialimmediately,andthecorresponding alarminformationis “security
alarm ;
Whenselect[2.delay],afteritreceivesignal, themaindialaftersometime, and thecorresponding alarminformation is “security
alarm ;
afterselect[3.24Hr], accordingtoyourneedselect[1.smoke],[2.gas],[3.panic],thecorrespondingalarminformationare"firealarm
″,"gasalarm″,"helpalarm″separately.
Whenselect [ 4.bypass], thearmzonedo not work.
setting 3.setup
—sirenalarmtimesetting1. alert
entermenu 1.alert→LCD display:
Afterinputting press #keytoconfirm,*** issiren’salarmdelay, can set to000~999sec, factoryset to300sec.
—guardsetting2. home
entermenu 2.home→LCD display:
Afterinputtingpress #keytoconfirm,**isthearmzoneNO.guarded.When hostisathome,afterhomearm,thesystemwill
ignoretheguardeddetector(forexample: PIRsensor). Sohost can movefreelyindoorand not arising alarming.
—telephonesetting
entermenu3.call→1.tel→LCD display:
1group isnetworkcenternumber, whenno network, you can not set thenumber;
2,3,4group isspeechalarmtelephonenumber.Ifyou needtodeletethenumber,onlysetthenumberto[0]. selectthetelephone
group No.(1-4),LCD display:
*************istelephonenumber, it can set to3~13 bitstelephonenumber.
Input delay
**
Input arm zone:
**
1.instant 2.delay
3.24Hr 4.bypass
1.Smoke 2.gas
3. Panic
Set alarm time
***
Set arm zone NO.
**
1.tel 2.tel
3.tel 4.tel
Input tel NO.
*************
1.Sys 2.Zone
3.Setup 4.Study
Press 2
2.Zone
1.Sys 2.Zone
3.Setup 4.Study
Press 3
1.alert 2.home
3.call 4.del home

—dialing setting
entermenu3.call→2.dial→LCD display:
press #keytoconfirm,**isdialtimes.Factorysetis3times;networkcenterisnotlimitedbyit until centertelephonereceiving alarm.
—vibrant ring setting
entermenu3.call→3. vibrant ring →LCD display:
press #keytoconfirm, ** islong-distancecontrolling vibrant ring times, can set to01~99 times, factoryset is8times.
—deletehome4.delhome
Deleteguardedarmzone, if usethestayfunction next time, you needreset it.
•study4.study
—studywireless(1.remote, 2.armzone)
Setting: ** +#
Attention:**isremotecontrollerNO.orarmzoneNO.,remotecontroller[1~4], andarmzone[05~12].Selecttheremotecontroller
NO. OrarmzoneNO.needing study,and press #keytoconfirm,whenLCD display“bestudying ,triggerremotecontrolleror
detectoronce, and thenstudynext one.
—deletewireless(3.del)
Deletewireless remotecontrollerorwireless detectors.
Functionoperation
4-keyremotecontrol coding
Thisremotecontroladaptsfree coding.Thecodingmethod:tightenoff thebasescrewand
openit, press and holdanyemission keyand theninstall battery, heretheLEDflash
indicating it iscoding. Thecoding isconfirmedwhenyou loosenthekey.(if you find remote
controllershaverepeat codlings, you can re-codeaccording abovemethod).
arm, disarm
Arm: press the[Awayarm]keyorthe[AWAY]keyon keypad,themaingive “systemarm
prompt sound and LCD displays “armst ;
Disarm: press the[Disarm]keyorpress userpasswordonkeypad,themaingive “system
disarm prompt sound and LCD displays “disarmst ;
HomeArm: press the[Homearm]orpress [HOME]keyon keypad,themaingive “system
arm prompt sound and LCD displays “guardst .
helpalarm
Remotecontrol:pressthe[helpalarm]keyonremotecontroller,themaindialandthenthesirenalarm,
themaingive “helpalarm alarminfo.
Keypad operation:press and holdMEDICAL/FIRE/HELPkeyfor3sec( “DI-DIDI promptsoundwillbe
heard),themaindialandthenthesirenalarm,themainseparatelygive medicalalarm, “firealarm
“helpalarm alarminfo.
keypadoperation
AWAY:AWAYarmkey
HOME: HOMEarmkey
SET: programming setting,[*]: returntothepreviousmenu whenprogramming.
[#]: Programming confirmkey.Keyisuseless.
speechreceiving alarm
When alarmtelephoneiscalled,pickup telephonehearalarminfo.And thenpress “#keytoconfirmand ring off, themainstop
dialing thetelephonenumber; Otherwiseit dialalarmtelephoneaccording todialtimespre-set.
long-distance control
Bylong-distancetelephoneorhand calldialthetelephoneconnectedwiththemain.Aftervibrantring forthetimespresetand
telephoneprompt “inputpassword,press1toarm,press2todisarm ,inputoperationpassword,press #key,enterlong-distance
control: press 1toarm, press 2todisarm, press 3tomonitorhearing, press 4toring off.
Installing
1.Untightenthescrewtoopentheunit (see fig.1);
2.Pullinwiresthroughtheout-lineholeonbottomcoverand thenconnectwiretoterminalsonPCBaccordingtoconnectionline
diagram.
3.Fixing thebottomcoveron neededposition(see fig.2)
Set dial times
**
Input ring times
**
1.Sys 2.Zone
3.Setup 4.Study
1.remote 2.arm zone
3.del
Press 4
help alarm
helpalarm
awayarm
homearm
disarm pushup
Z

4
.
Linkup front coverand tightenthescrews(see fig.3)
SensoremitterLX-AL8
—Jumpersetting (like rightfigure)
·Senseoncetoemit: aftersensingonce,the
sensoremit signal
·Sensetwicetoemit:aftersensingtwice,the
sensoremitsignal, Thissettingenhanceits
preventingfalse-alarmandpreventing-pet
function.
Note:theemitintervaltimeisatleast
15sec.thatmeans:sensetomakeit emit,after
atleast15secsenseitagain, it willemit again.
—Test
·press thearmkeyof remotecontrollerorthemain, set themaintoarm.
·set thejumperon neededposition;
·switchon 9Vbattery, after60sthesensorenterstableworking state;
·according tothestudying wireless method select studyarmzone(2.armzone)tostudyLX-AL8;
·movealongthetangentof thelens,thesenseLEDlight andthenitemitsignaltothemain,theemissionLEDlight. thesiren give
alarmand themaindial.
—Attention
·Low-batteryLED: When batteryenergyisbelow7V, thelow-batteryLEDwill flashonceasecondandremindyou replacebattery.
·Avoidinstalling theunit on metalbase;
·Avoidinstalling theunit wheresun shineortemperaturechangeobviously, forexample: airconditioning, heateretc.
DoormagnetismLX-DM1
·Installmagnetismandemitteronuprightpositionofdoorlock, thedistancebetweenthem
is3mm~5mm and triangleon emitteraimat triangleon magnetism(likeright figure);
·install DC12Vbatteryintoemitterand thenclosethebatterylid;
·according tothestudying wireless method selectstudyarmzone(2.armzone)tostudy
LX-DM1;
·press thearmkeyof remotecontrollerorthemain, set themaintoarm.
·Open door,theemitteristriggeredanditsLEDlight, thenemitsignaltothemain,thesiren
alarmand themaindial;
·tamperdesign:Undertheconditionthatthetriangleonemitteraimat triangleon magnetism,
whenthebatterylidisremoved, it will emit signaltothemain.
·Attention:
1
.
Avoidinstalling theunit on metalbase;
2
.
Themagnetismshouldbeon theleft of theemitter(likefollowing figure)
Warnning:
1.Noslideall numeralsoftheDIPswitchtoONpositionsimultaneously
whencoding!
2.you shouldnotuse numeral 1”on DIPswitchwhencoding.
Incorrectposition
Correctposition
Door
Doorframe
Doorlock
Fig. 1
Fig. 2
Fig. 3
out-linehole
78
160
AUTO
DIPswitch SenseLED
PIR
Jumper
AU TO / 1 AUTO / 1
1
EmitLED
Sense
onceto
emit
Sense
twiceto
emit
Low-batteryLED
Table of contents
Other Lexing Security System manuals
Popular Security System manuals by other brands

Honeywell
Honeywell VISTA-21iP Programming guide

ADEMCO
ADEMCO Vista-10P Installation and setup guide

Fortress Automotive Security
Fortress Automotive Security FS-22 operating instructions

Wuloo
Wuloo WL-T1905 quick start guide

Young Shin Electronics
Young Shin Electronics 2WSHR LCD user guide

SkyLink
SkyLink HA-434RTL manual

INIM Electronics
INIM Electronics Prime Programming manual

COBHAM
COBHAM SAILOR 3771 installation manual

MOVING INTELLIGENCE
MOVING INTELLIGENCE Caravan Sentinel user guide

ADEMCO
ADEMCO 4180 user manual

Iris Innovations
Iris Innovations CMAC-H16-xTB-x User guide & installation manual

Esse-ti