LG LW1800_Series User manual

LG
Window-Type Air Conditioner
OWNER'S MANUAL
LG
MODELS: LW1800_Series
IMPORTANT
Please read through this manual. It contains valuable
information about your air conditioner. This manual may help
save time and money by explaining proper air conditioner
maintenance and preventing improper use.
PRECAUTIONS
Pay close attention to precautions in order to prevent
potential hazards and damage from misuse or improper
installation. LG is not responsible for any damages caused by
misuse of the air conditioner.
FRANÇAIS ESPAÑOLENGLISH
As an ENERGY STAR®Partner,
LG Electronics Inc. has Determined
that this product meets the ENERGY STAR
®
guidelines for energy efficiency.
website http://www.lgservice.com
e-mail http://www.lgeservice.com/techsup.html

F or Your Records
R ead This Manual
CAUTION
2
Window-Type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
1. Safety Precautions
2. Operating Instructions
3. Care and Maintenance
4. Hardware Installation
5. Common Issues
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great
deal of time and money over the life of your air
conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
• Contact the authorized service technician for repair
or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.

WARNING
WARNING
WARNING
CAUTION
Never Do This
Always Do This
Precautions
Safety
Precautions
3
ENGLISH
To prevent injury and property damage, follow these instructions.
Incorrect operation due to ignoring instructions will cause harm or damage, the seriousness of which is
indicated by the following symbols.
■ The following items are classified by these symbols.
Plug in the power plug
properly. Do not operate or stop the
unit by inserting or pulling
out the power plug.
Do not damage or use an
unspecified power cord.
• Otherwise, it will cause electric
shock or fire due to heat
generation or electric shock.
• It will cause electric shock or fire
due to heat generation. • It will cause electric shock or fire.
•
If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similarly qualified person in
order to avoid a hazard. (Y attachment)
Do not modify power cord
length or share the outlet
with other appliances.
Do not operate with wet
hands or in damp
environment.
Always plug into a
grounded outlet.
• It will cause electric shock or fire
due to heat generation. • It will cause electric shock.
• No grounding may cause electric
shock (See Installation Manual).
Do not allow water to run
into electric parts. Always install air leakage
breaker and a dedicated
switching board.
Unplug the unit if strange
sounds, odors, or smoke
comes from it.
• It will cause failure of machine or
electric shock. • No installation may cause fire
and electric shock accident. • It may cause fire and electric
shock accident.
Do not use the socket if it is
loose or damaged. Do not open the entrance
during operation. Keep firearms away.
• It may cause fire and electric
shock. • It may cause electric shock. • It may cause fire.
Do not use the power cord close to the
heating tools.
Do not use the power cord near flammable gas
or combustibles such as gasoline, benzene,
thinner, etc.
• It may cause fire and electric shock. • It may cause an explosion or fire.
This symbol shows the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.

CAUTION
CAUTION
WARNING
WARNING
4
Never touch the metal parts
of the unit when removing
the filter.
Do not clean the air
conditioner with water. Ventilate well when used
together with a stove, etc.
• They are sharp and may cause
injury. • Water may enter the unit and
degrade the insulation. It may
cause an electric shock.
• An oxygen shortage may occur.
When cleaning the unit, first
make sure the power and
breaker are turned off.
Do not put a pet or house
plant where it will be
exposed to direct air flow.
Do not use appliance for special
purpose such as animals or
vegetables, precision machine, or
conservation of art articles.
• Since the fan rotates at high
speed during operation, it may
cause injury.
• This could injure the pet or plant. • It may cause damage of animals
or vegetables or loss of property.
Stop operation in storm or
hurricanes. Hold the plug by the head
when taking it out. Turn off the main power
switch when not using it for
a long time.
• Operation with windows opened
may cause wetting of indoor and
soaking of household furniture.
• It may cause electric shock and
damage. • It may cause failure of product or
fire.
Do not place obstacles
around the absorption inlet
or output.
Ensure that an installation console of
the outdoor appliance is not damaged
due to the use for a long time.
Always insert the filters
securely. Clean it every two
weeks.
• It may cause failure of appliance
or accident. • If leaving appliance damaged,
there is concern of damage due
to the falling of product.
• Operation without filters will
cause failure.
Do not use strong detergent
such as wax or thinner but
use a soft cloth.
Do not place heavy object on the
power cord and take care so that
the cord should not be pressed.
Do not drink water drained
from air conditioner.
• Appearance may be deteriorated
due to change of product color or
scratching of its surface.
• There is danger of fire or electric
shock. • It contains containments and will
make you sick.
Ventilate before operating air conditioner
when gas goes out. Do not disassemble or modify products
randomly.
• It may cause explosion, fire, and burn. • It may cause failure and electric shock.
If water enters the product, turn off the the
power switch of the main body of appliance.
Contact service center after taking the
power-plug out from the socket.
Do not direct airflow at room occupants only.
• This could damage your health.

Prior to Operation
Safety
Precautions
5
ENGLISH
Preparing for operation
Contact an installation specialist for installation.
Plug in the power plug properly.
Do not share the same outlet with other appliances
Do not use an extension cord.
Do not start/stop operation by plugging/unplugging the power cord.
If cord/plug is damaged, replace only with an authorized part.
6
5
4
3
2
1
Usage
Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not
expose occupants, pets, or plants to direct airflow for extended periods of time.
Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other
heating devices.
Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices,
food, pets, plants, and art objects). Usage in such a manner could harm such property.
3
2
1
Cleaning and maintenance
Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp
metal edges.
Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading
to possible electric shock.
When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a
very high speed during operation. There is a possibility of injury if the unit’s power is accidentally
triggered on while cleaning inner parts of the unit.
3
2
1
Service
For repair and maintenance, contact your authorized service dealer.

TIMER MODE TEMP
POWER
FAN
SPEED
COOL
INDOOR DESIRED
ENERGY
SAVER
AIR
PURIFIER
AUTO
RESTART
FAN
FAN
DRY
12345
6
TIMER MODE TEMP
POWER
FAN
SPEED
°F
12345
Air
Purifier Power
Temp
Sleep Mode
Timer Auto
Swing
Fan Speed
AIR
PURIFIER
17
8
2
4
3
5
F1 LOW
F2 MED
F3 HIGH
COOLDRY
ENERGY
SAVER
FANTIMER
6Power
Temp
Fan Speed
Timer Mode
1
2
3
4
5
6
Remote Control Operations
Operating
Instructions
The remote control and control panel will look like one of the following pictures.

ENGLISH
7
Push out the cover on the back of the remote control with your thumb
Pay attention to polarity and insert two new AAA 1.5V batteries.
Reattach the cover.
NOTE: Do not use rechargeable batteries. Make sure that both batteries are new.
•In order to prevent discharge, remove the batteries from the remote control if the
air conditioner is not going to be used for an extended period of time
Keep the remote control away from extremely hot or humid places.
To maintain optimal operation of the remote control, the remote sensor should
not be exposed to direct sunlight.
•The remote control can be mounted on a wall using the mountable holder.
3
2
1
Inserting the Remote Control Batteries
POWER
Operation starts when this button is pressed and
stops when you press the button again.
TEMPERATURE CONTROL
The thermostat monitors room temperature to
maintain the desired temperature.
The thermostat can be set between 60°F~86°F
(16°C~30°C).
The unit takes an average of 30 minutes to adjust
the room temperature by 1°F.
OPERATION MODE SELECTOR
Select cooling mode to cool the room.
Select energy saver mode for energy saving
operation.
Select fan mode for basic ventilating fan
operation.
Select dry mode for dry operation.
FAN SPEED SELECTOR
For increased power while cooling, select a
higher fan speed.
3 steps: High ➔Low ➔Med
ON/OFF TIMER
The timer can be set to start and stop the unit in
hourly increments (up to 12 hours).
REMOTE CONTROL SENSOR
AIR PURIFIER
•Press the Air Purifier button. Operation will start
when the button is pressed and stop when the
button is pressed again.
•Set the fan speed again with the remote control.
You can select the fan speed in three
steps-high, low or medium.
Each time the button is pressed, the fan speed
mode is shifted.
•If you press the only Air Purifier button, only air
purifying operates without cooling.
Then, fan speed is low.
You can select the fan speed in three steps;
high, low, or medium.
Each time the fan speed button is pressed, the
fan speed mode is shifted.
SLEEP MODE
•Press the sleep mode button to set the time you
want the unit to turn off automatically.
•Every time you push this button, the remaining
time will be set as follows. (1Hour →2Hours →
3Hours →4Hours →5Hours →6Hours →
7Hours →0Hours →1Hour →2Hours →...)
8
7
6
5
4
3
2
1
Remote Control OperationsRemote Control Operations

8
OPEN
TIMEMODETEMPPOWER
FAN
SPEED
VENTCLOSE
TIMEMODETEMPPOWER
FAN
SPEED
Part A
Adjusting the Air Flow Direction
Operating
Instructions
Vent Control
For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation.
OPEN the vent to discharge stale air.
Adjusting the Air Flow Direction
• Recommended orientation of louvers
Adjust louvers to face upwards when cooling to maximize cooling efficiency.
Airflow can be adjusted by changing the direction of the air conditioner's louvers. This can also increase the
cooling efficiency of the air conditioner.
• Adjusting Horizontal Air Flow Direction
Adjusting the vertical louvers left and right will
change horizontal airflow.
• Adjusting Vertical Air Flow Direction
Adjusting the horizontal vane up and down will
change vertical airflow. The vane can be adjusted
by nudging the back or up and down of the vane.
NOTE : Before using the ventilation feature, position the
vent lever straight by pulling Part A out and
snapping it into place.
Adjusting horizontal air flow Adjusting vertical air flow

Drain pipe
Drain cap
TIMEMODETEMPPOWER
FAN
SPEED
Care and Maintenance
Care and
Maintenance
9
ENGLISH
Turn the power off and unplug the power plug before cleaning the air conditioner.
Air Filter
The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as
necessary) to maintain optimal performance of the air conditioner.
How to remove the air filter
The grille may be opened from the top for easy
maintenance after installation.
Open the inlet grille by pulling off the exposed door
on the top of the unit (based on installation).
Pull the tab slightly to release the filter. Pull the filter
in the same direction as the opening.
Clean the filter with warm, soapy water. The water
should be below 40°C (104°F).
Rinse off and gently shake off excess water from the
filter. Let it dry before replaceing it.
5
4
3
2
1
Drainage
The base pan may overflow due to high humidity. To drain the excess
water, remove the drain cap from the back of the unit and secure the
drainpipe.
When pressing the drainpipe into place, apply force in the direction
away from the fins to avoid injuring yourself.

DEFROST
HEAT
COOL
INDOORDESIRED
ENERGY
SAVER
AIR
PURYFIER
AUTO
RESTART
FAN
FAN
DRY
CABINET
DRAIN
PAN
DRAIN HOSE
SCREW
10
After removing the Air Purifying Filter, pull
slightly forward to remove the Air Purifying filter.
Soak the Air Purifying Filter in water mixed with a
mild detergent for 20~30 minutes.
Dry the Air Purifying Filter in the shade for a
day.(The moisture must be removed completely
on this part.)
Note the cuts of electric discharge lines.
Re-install the Air Purifying Filter to the original
position.
Take the drain pan which is located in the air
discharge.
Remove the hole rubber from the base-pan (for
some models).
Install the drain pan to the right corner of the
cabinet with 4 (or 2) screws.
Connect the drain hose of 3/5" inside diameter to
the outlet located at the bottom of the drain
pan.You can purchase the drain hose or tubing
locally to satisfy your particular needs. (Drain
hose is not supplied).
4
3
2
1
5
4
3
2
1
The Air Purifying filter behind the air filter should be checked and cleaned once every 3 months or more often if
necessary.
The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the
air) is drained to the outside.
In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water removed
from the air may cause some water to collect. To remove this excess water you can install the drain pan as
detailed below.
Don't touch this Air Purifying Filter within
10 seconds after opening the inlet grille;
it may cause an electric shock.
Remote Control Operations
Air Purifying Filter (Optional)
Remote Control Operations
How to Attach Drain Pan

ENGLISH
DEFROST
HEAT
COOL
INDOORDESIRED
ENERGY
SAVER
AIR
PURYFIER
AUTO
RESTART
FAN
FAN
DRY
TIMEMODETEMPPOWER
FAN
SPEED
4
6
1
2
3
13
15
11
14
12
5
89
7
17
10
16
DEFROST
HEAT
COOL
INDOORDESIRED
ENERGY
SAVER
AIR
PURYFIER
AUTO
RESTART
FAN
FAN
DRY
Power Cord
DEFROST
HEAT
COOL
INDOORDESIRED
ENERGY
SAVER
AIR
PURYFIER
AUTO
RESTART
FAN
FAN
DRY
Power Cord
B
A
11
Hardware Installation
Hardware
Installation
Product Features
CAUTION
This appliance should be installed in accordance with national wiring regulations. This guide acts as a
guide to help to explain product features.
1. CABINET
2. FRONT GRILLE
3. AIR FILTER
4. AIR INTAKE (INLET GRILLE)
5. AIR DISCHARGE
6. VERTICAL AIR DEFLECTOR
(HORIZONTAL LOUVER)
7. EVAPORATOR
8. HORIZONTAL AIR DEFLECTOR
(VERTICAL LOUVER)
9. CONTROL PANEL
10. POWER CORD
11. COMPRESSOR
12. BASE PAN
13. BRACE
14. CONDENSER
15. REMOTE CONTROLLER
16. AIR PURIFYING FILTER (Optional)
17. CASE, FILTER (Optional)
Installing the Power cord
You can choose between two methods below according to your window stool shape and preference.
•Fasten the stopper using 2 screw holes, and lead
out the power cord through slit "A". •Fasten the stopper using left screw hole, and rotate
properly to lead the power cord out through slit "B".
Using slit "A" Using slit "B"

;
;
y
y
About 1/2"
30"~60"
Awning
Cooled air
Fence
Over 20"
Heat
radiation
26" to 41"
18" min. Inner sill Offset
Window
Sash
Sill
Exterior
Interior wall
26" min.
(Without frame curtain)
12
How to Install the Unit
To prevent vibration and noise, make sure the unit
is installed securely and firmly.
Install the unit where the sunlight does not shine
directly on the unit.
There should be no obstacles, such as a fence and
wall, within 20" from the back of the cabinet
because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.
Install the unit a little slanted so the back is slightly lower than the front (about 1/2").
This will force condensed water to flow to the outside.
Install the unit with the bottom about 30"~60" above the floor level.
5
4
3
2
1
Window Requirements
NOTE: All supporting parts should be secured to firm wood, masonry, or metal.
•This unit is designed for installation in standard double
hung windows with actual opening widths from 26"
to 41".
•The top and bottom window sash must open sufficiently
to allow a clear vertical opening of 18" from the bottom
of the upper sash to the window stool.

ENGLISH
11
14
15
Shipping
Screws
DEFROST
HEAT
COOL
INDOORDESIRED
ENERGY
SAVER
AIR
PURYFIER
AUTO
RESTART
FAN
FAN
DRY
DEFROST
HEAT
COOL
INDOORDESIRED
ENERGY
SAVER
AIR
PURYFIER
AUTO
RESTART
FAN
FAN
DRY
14
(Type A)
5
(Type A)
1 2 3 4 5
6 7 8 9 10 11
16 12 13
14
15
5
16
13
Installation Kits Contents
Suggested Tool Requirements
NO. NAME OF PARTS Q'TY
1 FRAME CURTAIN 2
2 SUPPORT BRACKET 2
3 SILL BRACKET 2
4 LOCK NUT 4
5 SCREW (TYPE A) 14
6 SCREW (TYPE B) 7
7 SCREW (TYPE C) 5
8 SCREW (TYPE D) 2
9 CARRIAGE BOLT 2
10 FOAM STRIP 1
11 FOAM SEAL 1
12 WINDOW LOCKING BRACKET 1
13 DRAIN PIPE 1
14 UPPER GUIDE 1
15 FOAM-PE 1
16 FRAME GUIDE 2
PREPARATION OF CHASSIS
Remove the screws which fasten the cabinet at both
sides and at the back.
Slide the unit from the cabinet by gripping the base pan
handle and pulling forward while bracing the cabinet.
Cut the window sash seal to the proper length.
Peel off the backing and attach the Foam-Seal to the
underside of the window sash.
Remove the backing from the top upper guide Foam-PE
and attach it to the bottom of the Upper Guide .
Attach the upper guide onto the top of the cabinet with 3
Type A screws .
Insert the Frame Guides into the bottom of the
cabinet.
Insert the Frame Curtain into the Upper Guide and
Frame Guides .
Fasten the curtains to the unit with 10 Type
A screws .
8
7
6
5
4
3
2
1
SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL

3
9
2
6
3
14
14
15
11
2
4
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Support
Bracket
Lock nut
Sill
Bracket
Carriage
Bolt
Front angle Window stool
Window sash Upper Guide
Cabinet
Foam
-Seal
Frame curtain
Foam-PE
(Type B)
Cabinet
Track hole
Support
Bracket
Carriage bolt
and lock nut
Machine screw(Type D)
and lock nut
Outer edge
of window
sill
Sill bracket
Upper
Guide
14
Cabinet Installation
Open the window. Mark a line on the center of the
window stool between the side window stop
moldings.
Loosely attach the sill bracket to the support
bracket using the carriage bolt and the lock nut.
Attach the sill bracket to the window sill using the
screws (Type B).
Carefully place the cabinet on the window stool
and align the center mark on the bottom front with
the center line marked window stool.
Using the M-screw and the lock nut, attach the
support bracket to the cabinet track hole. Use the first
track hole after the sill bracket on the outer edge of
the window sill. Tighten the carriage bolt and the lock
nut. Be sure the cabinet slants outward.
CAUTION: Do not drill a hole in the bottom pan.
The unit is designed to operate with
approximately 1/2" of water in bottom pan.
Pull the bottom window sash down behind the Top
retainer bar until they meet.
NOTE: 1. Do not pull the window sash down so tightly
that the movement of Frame curtain is restricted.
Attach the cabinet to the window stool by driving
the screws (Type B) through the cabinet into
window stool.
2. The cabinet should be installed with a very slight
tilt downward toward the outside.
4
3
2
1

ENGLISH
(Type C)
6
7
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Screw
Screw
DEFROST
HEAT
COOL
INDOORDESIRED
ENERGY
SAVER
AIR
PURYFIER
AUTO
RESTART
FAN
FAN
DRY
Screw(Type B)
Front Angle
Sash track
Window locking
bracket
Foam-Strip
Power Cord
15
Pull each Frame curtain fully to each window sash
track, and pull the bottom window sash down behind
the Top retainer bar until it meets.
Attach each Frame curtain the window sash by using
screws (Type C.) (See Fig. 6)
Slide the unit into the cabinet.(See Fig. 7)
CAUTION: For security purpose, reinstall screws(Type A)
at cabinet's sides.
Cut the Foam-strip to the proper length and insert
between the upper window sash and the lower
window sash.(See Fig. 8)
Attach the Window locking bracket with a screw
(Type C.) (See Fig. 9)
9
8
7
6
5

Fig. 10
TIMEMODETEMPPOWER
FAN
SPEED
Line Cord Plug Use Wall Receptacle
230V/208V
tandem type
Power Supply
Use 15 AMP circuit.
Refer to nameplate for
correct fusing.
16
Attach the front grille to the cabinet by inserting the
tabs on the grille into the tabs on the front of the
cabinet. Push the grille in until it snaps into place.
(See Fig.10)
Lift the inlet grille and secure it with a screw (Type A)
through the front grille.(See Fig. 10)
Window installation of room air conditioner is now
completed. See ELECTRICAL DATA for attaching
power cord to electrical outlet.
12
11
10
Electrical Data
All wirring should be made in accordance with local electrical codes and regulations.
NOTE:
Aluminum house wiring may pose special problems.
Consult a qualified electrician.

ENGLISH
PREFERRED METHOD
Ensure proper ground
exists before use
Fig. 11
3-prong
grounding
plug
Ground
prong
Power
supply
cord
3-prong
grounding
type wall
receptacle
17
Electrical Safety
IMPORTANT
(PLEASE READ CAREFULLY)
FOR THE USER'S PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED
The power cord of this appliance is equipped with a
three-prong (grounding) plug. Use this with a standard
three-slot (grounding) wall power outlet (Fig. 11) to
minimize the hazard of electric shock. The customer
should have the wall receptacle and circuit checked by
a qualified electrician to make sure the receptacle is
properly grounded.
DO NOT CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER PLUG.
FUSE –Use a time-delay fuse or circuit breaker. Refer
to serial plate for proper power supply
requirements.
230, 208, and 230/208 VOLT UNITS
These units are equipped with a three-prong grounding
plug on the power supply cord, which must be plugged
into a matching properly grounded three-prong wall
receptacle for your protection against possible shock
hazard. If such an outlet is not present, one must be
installed by a qualified electrician in accordance with
the National Electrical Code and local codes and
ordinances.
NOTE: DO NOT USE AN EXTENSION CORD
on 230, 208, and 230/208 Volt units.

18
18
Common Problems and Solutions
Common
Issues
Before calling for service, please review the following list of common problems and solutions.
The air conditioner is operating normally when:
•You hear a pinging noise. This is caused by water being picked up by the condenser on rainy days or in highly
humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency.
•You hear the thermostat click. This is caused by the compressor cycle starting and stopping.
•You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid
conditions or on rainy days. This water overflows and drips from the rear of the unit.
•You hear the fan running while the compressor is silent. This is a normal operational feature.
The air conditioner may be operating abnormally when:
Problem Possible Causes What To Do
■The air conditioner is unplugged or
not plugged in completely
■The fuse is blown/circuit breaker is
triggered
■Power failure.
■Air flow is restricted
■The THERMOSTAT may not be
set cool enough
■The air filter is dirty.
■The air conditioner was just
turned on.
■Cold air is escaping.
■Cooling coils are iced up
■The cooling coils are iced over.
•Make sure the plug is completely plugged into
the outlet
•Check the fuse/circuit breaker box and replace
the fuse or reset the breaker
•In the event of a power failure, set the power
control to OFF. When the power is restored,
wait 3 minutes to restart the air conditioner to
prevent the compressor from overloading
•Make sure there are no curtains, blinds,
furniture or other obstacles in front of the air
conditioner
•Turn the knob to a higher setting. The highest
setting provides maximum cooling
•Clean the filter at least every 2 weeks. Refer to
the “Care and Maintenance”section (p.9) of the
manual.
•After the air conditioner is turned on, you need
to give the air conditioner some time to cool the
room.
•Check for open furnace floor resisters and cold
air returns.
•CLOSE the air conditioner vent
•See Ice appears on the air conditioner below
•Ice may block the air flow and obstruct the air
conditioner from properly cooling the room. Set
the fan at MED or HIGH while setting the
thermostat at 1 or 2 until the ice melts.
The air conditioner
does not operate
at all
Air conditioner
does not cool
Ice appears on the
air conditioner.
❈You can refer to the Energy Star program in detail at "www.energystar.gov".
This manual suits for next models
1
Table of contents
Other LG Air Conditioner manuals