LG PQRCHCA0Q Quick start guide

P/NO : MFL62862003 www.lg.com
OWNER’S &
INSTALLATION MANUAL
SIMPLE WIRED REMOTE
CONTROLLER
Please read this manual carefully before operating
your set and retain it for future reference.
MODELS : PQRCHCA0Q
PQRCHCA0QW
ENGLISH ITALIANO ESPAÑOL
FRANÇAIS
DEUTSCH
PORTUGUESE
РУССКИЙ ЯЗЫК

TIPS FOR SAVING ENERGY
2
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
• Do not cool excessively indoors. This may be harmful for your health and may consume
more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con-
ditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may
block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :

3
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation MUST conform with local building codes or, in the absence of local codes, with
the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical
Code Part1 CSA C.22.1.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal-
function, property damage, personal injury and/or death.
Installation
• Be sure to request to the service center or installation specialty store when installing prod-
ucts.
- It will cause fire or electric shock or explosion or injury.
• Request to the service center or installation specialty store when reinstalling the installed
product.
- It will cause fire or electric shock or explosion or injury.
• Do not disassemble, fix, and modify products randomly.
- It will cause fire or electric shock.
Operation
• Do not place flammable stuffs close to the product.
- It will cause fire.
• Do not allow water to run into the product.
- It will cause electric shock or breakdown.
• Do not give the shock to the product.
- It will cause breakdown when giving the shock to the product.
• Request to the service center or installation specialty store when the product becomes wet.
- It will cause fire or electric shock.
• Do not give the shock using sharp and pointed objects.
- It will cause breakdown by damaging part.
!
!
!
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH

CAUTION
• Do not clean using the powerful detergent like solvent but use soft cloths.
- It will cause fire or product deformation.
• Do not press the screen using powerful pressure or select two buttons.
- It will cause product breakdown or malfunction.
• Do not touch or pull the lead wire with wet hands.
- It will cause product breakdown or electric shock.
!
IMPORTANT SAFETY INSTRUCTIONS
4
ENGLISH

5
TABLE OF CONTENTS
TABLE OF CONTENTS
ENGLISH
2TIPS FOR SAVING
ENERGY
3IMPORTANT SAFETY IN-
STRUCTIONS
6PART DESCRIPTION
6Using the remote control
6Accessory
7INSTALLATION IN-
STRUCTION
8Group Control
9Install Setting
9- How to enter installer setting mode
10 - Installer Setting Code Table
11 - Test Run Mode
11 - Setting Address of Central control
12 - E.S.P
12 - Thermistor
13 - Ceiling Height Selection
13 - Static Pressure Setting
14 - Remote Controller Master/Slave Set-
ting
14 - Fahrenheit Switching
15 OWNER'S INSTRUC-
TION
15 Standard Operation
15 - Cooling Mode
15 - Heating Mode
15 - Auto Operation Mode
15 - Dehumidification Mode
15 - Fan Mode
16 Function setting
16 - Fan Speed Selection
16 - Room Temperature Check
16 - Child Lock

Accessory
6PART DESCRIPTION
ENGLISH
Display screen
Control button
TEMP
FAN
SPEED
ROOM
TEMP
Connection Cable
(1EA, 10m)
Screw
(2 EA)
Owner's / Installation
manual
Control
panel Display screen Description
T
Temperature adjustment button:
Adjusts the room temperature when
cooling and heating.
Indoor fan speed button:
Adjusts the fan speed.
On/Off button:
Turns the power on/off.
Displays the room temperature.
Using the remote control
PART DESCRIPTION
18~30°C
Ex)

INSTALLATION INSTRUCTION 7
ENGLISH
INSTALLATION INSTRUCTION
1Please fix tightly using provided screw
after placing remote controller setup board
on the place where you like to setup.
- Please set it up not to bend because poor
setup could take place if setup board
bends.
Please set up remote controller board fit
to the reclamation box if there is a recla-
mation box.
2Can set up Wired remote controller cable
into three directions.
- Setup direction: the surface of wall recla-
mation, upper, right
- If setting up remote controller cable into
upper and right side, please set up after
removing remote controller cable guide
groove.
❈Remove guide groove with long nose.
① Reclamation to the surface of the wall
② Upper part guide groove
③ Right part guide groove
3 Please connect indoor unit and remote
controller using connection cable.
4 Please use extension cable if the distance
between wired remote controller and in-
door unit is more than 10m.
5Please fix remote controller upper part into
the setup board attached to the surface of
the wall, as the picture below, and then,
connecta with setup board by pressing
lower part.
- Please connect not to make a gap at the
remote controller and setup board’s
upper and lower, right and left part.
When separating remote controller from
setup board, as the picture below, after in-
serting into the lower separating hole
using screw driver and then, spinning
clockwise, remote controller is separated.
- There are two separating holes. Please
individually separate one at a time.
- Please be careful not to damage the in-
side components when separating.
Wall
Side
Wall
Side
<Connecting order>
TEMP
FAN
SPEED
ROOM
TEMP
Please check if connector
is normally connected.
Connecting
cable
Indoor
Unit
side
Wall
Side
Wall
Side
<Separating order>
<Wire guide grooves>

8INSTALLATION INSTRUCTION
ENGLISH
Group Control
1When installing more than 2 units of air
conditioner to one wired remote controller,
please connect as the right figure.
- If it is not event communication indoor
unit, set the unit as slave.
- Check for event communication through
the product manual.
2 When installing more than 2 wired remote
controllers to one air conditioner, please
connect as the right picture.
- When installing more than 2 units of
wired remote controller to one air condi-
tioner, set one wired remote controller as
master and the others all as slaves, as
shown in the right picture.
- You cannot control the group as shown in
the right for some products.
- Refer to the product manual for more de-
tail. When controlling multiple indoor
units with event communication function
with one remote controller, you must
change the master/slave setting from the
indoor unit.
- For ceiling type cassette and duct prod-
uct group, change the switch setting of
the indoor PCB.
- For wall-mount type and stand type prod-
uct, change the master/slave setting with
the wireless remote controller. (Refer to
wireless remote controller manual for de-
tail)
❈When installing 2 remote controllers to
one indoor unit with event communica-
tion function, set the master/slave of
the remote controller. (Refer to remote
controller master/slave selection)
When controlling the group, some func-
tions excluding basic operation setting,
fan level
Min/Mid/Max, remote controller lock
setting and time setting may be limited.
3When installing more than 2 wired remote
controllers to one air conditioner, please
connect as the right picture.
- When installing more than 2 units of
wired remote controller to one air condi-
tioner, set one wired remote controller as
master and the others all as slaves, as
shown in the right picture.
- You cannot control the group as shown in
the right for some products.
- Refer to the product manual for more de-
tail.
GND
GND
12V
Signal wire
Signal wire
TEMP
FAN
SPEED
ROOM
TEMP
GND
12V
BY R BY R
MASTER SLAVE
Signal wire GND
12V
Signal wire
TEMP
FAN
SPEED
ROOM
TEMP
TEMP
FAN
SPEED
ROOM
TEMP
1
ON
2345678
1
ON
2345678
#3 switch OFF: Master
(Factory default setting)
#3 switch ON: Slave
- When controlling in groups, set the
master/slaver of the remote controller.
Refer to Installer setting section on how
to set master/slave for more detail.

INSTALLATION INSTRUCTION 9
ENGLISH
Install Setting
How to enter installer setting mode
1If you want to set installer setting mode,
Press the Temperature up button and the
Room Temp button same time for five sec-
onds.
2When you enter the setting mode Initially.
Function code is displayed on the LCD
screen.
TEMP
FAN
SPEED
ROOM
TEMP
- Some categories of the menu may not
be displayed according to the function
of the product, or the menu name may
be different.
CAUTION
• Installer setting mode is to set the de-
tail function of the remote controller.
If the installer setting mode is not set
correctly, it can cause problems to the
product, user injury or property dam-
age. This must be set by an certificated
installer, and any installation or change
that is carried out by a non-certificated
person should be responsible for the re-
sults. In this case, free service cannot
be provided.
!
Function Code
Value

10 INSTALLATION INSTRUCTION
ENGLISH
<Installer Setting Code Table>
1General air-conditioner product
❊Some contents may not be displayed depending on the product function
No. Function Code Value
1Te st Run 01 01:Set
2Address Setting 02 00~FF : Address
3E.S.P. Value 03
<ESP Step> <ESP Value> <Example>
01:VeryLow 0 ~ 255
02:Low
03:Med
04:High
05:Very High
4Thermistor 04
01:Remo
02:Indoor
03:2TH
5Ceiling Height 05
01:Med
02:Low
03:High
04:Very High
6Static Pressure 06
01:V-H
02:F-H
03:V-L
04:F-L
7Master Setting 07 00:Slave
01:Master
8Celsius
Fahrenheit
Switching
12 00:Celsius
01:Fahrenheit
Function Code ESP valueESP step
(Optimized only for U.S.A)

Setting Address of Central control
INSTALLATION INSTRUCTION 11
ENGLISH
After installing the product, you must a test
Run Mode. For details related to the Product
manual.
1Press button and button Simulta-
neouslly for more than 3 seconds.
2Setup figure ’01’ blinks
3Press button to start.
4During the test run, pressing the below
button will exit run.
It’s the functional to use connecting central
control.
1Press button and button Simulta-
neouslly for more than 3 seconds.
2Setup function code ’02’ pressing by
button.
3Set group number and indoor number.
4Press button to save.
5Press button and button Simulta-
neouslly for more than 3 seconds After the
setting has been completed.
Function Code
Value
Function Code
Value
TEMP
Group number
Control button
NOTE
!
• After setup, it automatically gets out of
setup mode if there is no button input
for 25seconds.
• When existing without pressing set but-
ton, the manipulated isn’t reflected.
Test Run Mode

Thermistor
12 INSTALLATION INSTRUCTION
ENGLISH
This is the functional that decides the strenth
of the wind for each wind level and because
this function is to make the installation easier.
- If you set ESP incorrectly, the air conditional
may malfunktion.
- This setting must be carried out by a certifi-
cated-thecnition.
1Press button and button Simulta-
neouslly for more than 3 seconds.
2Setup function code ’03’ pressing by
button.
3Select ESP fan step and ESP value.
* ESP value range : 0~255
4Press button to save.
5Press button and button Simulta-
neouslly for more than 3 seconds After the
setting has been completed.
This is the function to select the temprature
sensor to judge the room temperature.
1Press button and button Simulta-
neouslly for more than 3 seconds.
2Setup function code ’04’ pressing by
button.
3Set Thermistor value by pressing button by
pressing temperature button.
(01: Remote Controller, 02: Indoor, 03: 2TH)
4Press button to save.
5Press button and button Simulta-
neouslly for more than 3 seconds After the
setting has been completed.
NOTE
!
• When setting ESP value on the product
without very weak wind or power wind
function, it may not work.
• Please be careful not to change the ESP
value for each fan step.
• It does not work to setup ESP value for
very low/power step for some product.
• ESP value is available for specific range
belongs to the product.
NOTE
!
❈The function of 2TH has difference op-
eration characterics according to prod-
uct.
• C
Cooling:
Operation of higher tempera-
ture by comparing indoor unit’s and
wired remote controller’s temperature.
(there are products that operate at a
lower temperature.)
• H
Heating:
Operation of lower temperature
by comparing indoor unit’s and wired re-
mote controller’s temperature.
Function Code
Value
ESP step
ESP Value ESP step
Function Code
Thermistor value
E.S.P

INSTALLATION INSTRUCTION 13
ENGLISH
This function is to adjust FAN Airflow rate ac-
cording to ceiling height (For ceiling type prod-
uct)
1Press button and button Simulta-
neouslly for more than 3 seconds.
2Setup function code ’05’ pressing by
button.
3Set Thermistor value by pressing button by
pressing temperature button.
(01: Remote Controller, 02: Indoor, 03:
2TH)
4Press button to save.
5Press button and button Simulta-
neouslly for more than 3 seconds After the
setting has been completed.
This function is applied to only duct type. Set-
ting this in cases will cause malfunction.
1Press button and button Simulta-
neouslly for more than 3 seconds.
2Setup function code ’06’ pressing by
button.
3Set Thermistor value by pressing button by
pressing temperature button.
(01: V-H, 02: F-H, 03: V-L, 04:F-L)
4Press button to save.
5Press button and button Simulta-
neouslly for more than 3 seconds After the
setting has been completed.
Function Code
Function Code
Value
Thermistor value
NOTE
!
• Ceiling height setting is available only for
some products.
• Ceiling height of “Very high” function
may not exist depending on the indoor
units.
• Refer to the product manual for more
details.
Pressure
selection
Function
Zone
state
ESP
standard
value
01 V-H Variable High
02 F-H Fixed High
03 V-L Variable Low
04 F-L Fixed Low
Static Pressure Setting
Ceiling Height Selection

Fahrenheit Switching
14 INSTALLATION INSTRUCTION
ENGLISH
It’s a function for setting in group control, or 2-
remote controller control.
1Press button and button Simulta-
neouslly for more than 3 seconds.
2Setup function code ’07’ pressing by
button.
3Select Master/Slave by pressing tempera-
ture button. (00: Slave, 01: Master)
4Press button to save.
5Press button and button Simulta-
neouslly for more than 3 seconds After the
setting has been completed.
-
Refer to eh ‘Group control’ part for details.
• When controlling in groups, basic operation
settings, airflow strength
weak/medium/strong, lock setting of the re-
mote controller, time settings, and other
functions may be restricted.
This function is used for switching the display
between Celsius and Fahrenheit.
(Optimized only for U.S.A)
1Press button and button Simulta-
neouslly for more than 3 seconds.
2Setup function code ’12’ pressing by
button.
3Select Temperature unit mode by tempera-
ture button.
(00: Celsius , 02: Fahrenheit)
4Press button to save.
5Press button and button Simulta-
neouslly for more than 3 seconds After the
setting has been completed.
❈Whenever press button in Fahren-
heit mode, the temperature will
increase/drop 2 degrees.
Function Code
Fahrenheit setting
value
Function Code
Master/Slave Value
Remote
Controller Function
Master
Indoor unit operates based on
master remote controller at
group control. (master is set
when delivering from the ware-
house.)
Slave
Setup all remote controllers ex-
cept one master remote con-
trooler to slave at group control.
Remote Controller Master/Slave
Setting

OWNER'S INSTRUCTION 15
ENGLISH
Fan Mode
Dehumidification Mode
Heating Mode
Cooling Mode
Standard Operation
❈The operation mode can be set from Cen-
tral Controller only.
It cools the room by comfortable and Clean
wind.
1Press the button.
2Adjust the desired temperature by press
the temperature button.
(Temp range : 18°C~30°C (64°F~86°F)
It supplies warm wind to the indoor.
1Press the button.
2 Adjust the desired temperature by press
the temperature button.
(Temp range : 16°C~30°C (60°F~86°F)
It makes the room cool using pleasant and
fresh air quickly
1Press the button.
2When the room temperature is lower than
the desired temperature
: Heating Operation starts (For Heat Pump
models only)
When the room temperature is higher than
the desired temperature
: Cooling Operation starts
It removes humidity while ari-cooling Weakly.
1 Press the button.
It blows the air as it is in the indoor, not
1 Press the button.
❈Temperature control is not available during
the Dehumidification & Fan operation.
OWNER'S INSTRUCTION
Auto Operation Mode

Function setting
You can easily control the fan speed.
1 Press the button.
2 Press the button.
1 Press the button.
It is the function to use preventing children
or others from careless using.
1 Press button and button Simulta-
neouslly for more than 3 seconds.
16 OWNER'S INSTRUCTION
ENGLISH
NOTE
!
• If the product is not compatible with
The fan speed control, it will not func-
tion as per your selection.
NOTE
!
• “To change the temperature display to
Celsius or Fahrenheit, change LCD dis-
play by referring to page 14.”
• As the temperature distribution of the
remote controller installation space is
not Uniform, slight difference can be
generated between the actually felt tem-
perature and the room temperature indi-
cation of the remote controller.
NOTE
!
•
After the setting of the ‘CL’, if another
button is setup , the button can not be
recognized as the ‘CL’ is indicatied at
the temperature display section.
Room Temperature Check
Fan Speed Selection
Fan Speed Selection in Cooling Operation
Fan Speed Selection in Heating, Dry, Fan,
Auto-Operation
Po
Hi
Med
Lo
Hi
Med
Lo
Child Lock
This manual suits for next models
1
Table of contents
Other LG Remote Control manuals

LG
LG V-NET ACS PREMTA000B Instruction Manual

LG
LG AKB32977003 User manual

LG
LG PREMTB001 Quick start guide

LG
LG Magic Remote User manual

LG
LG AN-MR600 Operation manual

LG
LG Magic Remote Owner's manual

LG
LG PREMTW101 Quick start guide

LG
LG MR21GA Operation manual

LG
LG PQRNC0 Quick start guide

LG
LG AN-MR500G User manual

LG
LG Magic Remote AN-MR19BA User manual

LG
LG AKB732955 User manual

LG
LG Magic Remote Premium User manual

LG
LG Magic Remote AN-MR650 User manual

LG
LG MR22GN User manual

LG
LG MultiSITE CRC1 Series User manual

LG
LG PQCSB101S0 User guide

LG
LG AN-MR18BA User manual

LG
LG PQRCUSA1 Quick start guide

LG
LG Magic Remote User manual