manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LI-COR
  6. •
  7. Measuring Instrument
  8. •
  9. LI-COR LI-200R User manual

LI-COR LI-200R User manual

Other manuals for LI-200R

3

This manual suits for next models

1

Other LI-COR Measuring Instrument manuals

LI-COR LI-870 Guide

LI-COR

LI-COR LI-870 Guide

LI-COR li-7200 User manual

LI-COR

LI-COR li-7200 User manual

LI-COR LI-820 User manual

LI-COR

LI-COR LI-820 User manual

LI-COR LI-3000C User manual

LI-COR

LI-COR LI-3000C User manual

LI-COR LI-3100C User manual

LI-COR

LI-COR LI-3100C User manual

LI-COR LI-850 User manual

LI-COR

LI-COR LI-850 User manual

LI-COR LI-800 Guide

LI-COR

LI-COR LI-800 Guide

LI-COR LI-7810 User manual

LI-COR

LI-COR LI-7810 User manual

LI-COR LI-8100A User manual

LI-COR

LI-COR LI-8100A User manual

LI-COR LI-840/A User manual

LI-COR

LI-COR LI-840/A User manual

LI-COR LI-600 User manual

LI-COR

LI-COR LI-600 User manual

LI-COR LAI-2000 How to use

LI-COR

LI-COR LAI-2000 How to use

LI-COR LI-8100A User manual

LI-COR

LI-COR LI-8100A User manual

LI-COR LI-8100A User manual

LI-COR

LI-COR LI-8100A User manual

LI-COR LI-7820 User manual

LI-COR

LI-COR LI-7820 User manual

LI-COR LAI-2200 User manual

LI-COR

LI-COR LAI-2200 User manual

LI-COR LI-600N User manual

LI-COR

LI-COR LI-600N User manual

LI-COR LI-250A User manual

LI-COR

LI-COR LI-250A User manual

LI-COR TriSonica LI-560 User manual

LI-COR

LI-COR TriSonica LI-560 User manual

LI-COR Eddy Covariance User manual

LI-COR

LI-COR Eddy Covariance User manual

LI-COR LI-8100 User manual

LI-COR

LI-COR LI-8100 User manual

LI-COR LI-7700 User manual

LI-COR

LI-COR LI-7700 User manual

LI-COR LI-250A User manual

LI-COR

LI-COR LI-250A User manual

LI-COR 4300 User manual

LI-COR

LI-COR 4300 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installing the LI-200R Pyranometer in
Biomet Systems
The LI-200R Pyranometer (part number 7900-195) measures
hemispherical solar radiation. Here we provide basic install-
ation and operation instructions for using the LI-200R
Pyranometer in a LI-COR biomet data acquisition system.
LI-200R Specifications:
Spectral response: 400 to 1100 nm
Energy range: 0 to 1000 W/m2
Absolute calibration: ±5%
Output signal: 0 to 100 µA
Linearity: Maximum deviation of 1% up to 3,000
W/m2
Cosine correction: up to 80° angle of incidence
Azimuth error: <1% over 360° at a 45° elevation angle
Cable lengths: 5 and 50 meters
Siting the pyranometer
Position the LI-200R so it will never be under a shadow,
either from the surrounding landscape elements or from the
tower itself. Mount the sensor on the tower to minimize
reflected radiation that is visible to the sensor.
Mounting the pyranometer
Mount the LI-200R in the mounting and leveling fixture
(2003S). Attach the 2003S to the 7900-350 radiation sensor
bracket and level the 2003S. Secure the cable to the tower
using zip-ties.
Wiring the pyranometer
The bare leads connect directly to the DAqM.
Description Color Terminal
Signal (-) Brown A17
Signal (+) Blue G9
Shield Bare G9
If you want to connect the LI-200R to a channel other than
A17 or A18, a millivolt adapter is required.
Entering calibration data
Enter the calibration multiplier in the Blueprint Utility soft-
ware. The multiplier on the calibration certificate is under
For use with LI-COR handheld meters and loggers: (units are watts
m-2 per microamp).
Installation Guide
1
Select a program (Biomet Library) and then enter the cal-
ibration multiplier from the calibration sheet.
Save the configuration and push the file to the data acquis-
ition system after entering the remaining calibration inform-
ation.
Retrieving data
The SmartFlux System will log these data in compressed
files for processing by EddyPro Software and evaluation by
Tovi Software. Data are stored on the USB drive on the
SmartFlux System. Refer to the Data Acquisition System
instruction manual for details.
Maintenance
Keep the surface and vertical edge of the acrylic diffuser
clean. As needed, clean the diffuser sensor with water, mild
detergent, or vinegar dilute using a soft, lint-free cloth. DO
NOT use alcohol, organic solvents, strong detergents, abras-
ive solvents, or abrasive cloth on the diffuser. Return the
sensor to LI-COR for factory recalibration every two years.
Contact technical support for more information.
Copyright © 2020 LI-COR, Inc. All rights reserved.
988-12677 Rev 3•10/2020
LI-COR Biosciences
4647 Superior Street
Lincoln, Nebraska 68504
Phone: +1-402-467-3576
Toll free: 800-447-3576 (U.S. and Canada)
envsales@licor.com
LI-COR Distributor Network:
www.licor.com/env/distributors
Regional Offices
LI-COR Biosciences GmbH
Siemensstraße 25A
61352 Bad Homburg
Germany
Phone: +49 (0) 6172 17 17 771
envsales-gmbh@licor.com
LI-COR Biosciences UK Ltd.
St. John’s Innovation Centre
Cowley Road
Cambridge
CB4 0WS
United Kingdom
Phone: +44 (0) 1223 422102
envsales-UK@licor.com