manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. Light Fixture
  8. •
  9. Lightolier Calculite C7E17VW User manual

Lightolier Calculite C7E17VW User manual

Calculite®HID Downlight C7E17VW
Page 1 of 2 7" Aperture, ED17 (Enclosed), Ceramic Metal Halide, Wide Beam
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Ceiling Cutout: 8" (203 mm) Dia.
Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH)
C7E17VW CLW Specular Clear, White Painted Flange.
CLP Specular Clear, Matching Flange.
CCDW Comfort Clear Diffuse, White Painted Flange.
CCDP Comfort Clear Diffuse, Matching Flange.
CCZW Champagne Bronze, White Painted Flange.
CCZP Champagne Bronze, Matching Flange.
C770MHE1 Electronic 120V 70W ED17, BD17 (Enclosed)
C770MHE2 Electronic 277V 70W ED17, BD17 (Enclosed)
C710MHE1 Electronic 120V 100W ED17, BD17 (Enclosed)
C710MHE2 Electronic 277V 100W ED17, BD17 (Enclosed)
C770MHU Magnetic 120V/277V 70W ED17, BD17 (Enclosed)
C710MHU Magnetic 120V/277V 100W ED17, BD17 (Enclosed)
Features
1. Upper Reflector: Clear anodized aluminum, 0.040” (16-ga.). Provides wide
beam distribution.
2. Aperture Cone: Provides 50° visual cut-off to lamp and lamp image;
self-flange in painted white or aperture-matching polished flange. Consult
factory for other finishes.
3. Lamp Guard: High heat resistant glass as required by code.
4. Socket Housing: Galvanized steel, snaps onto upper reflector for secure
attachment without tools; assures proper lamp alignment to optics for
consistent performance.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed
mounting bars.
6. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
7. Retention Springs: Rust resistant springs secure cone in place for quick,
tool-less installation.
8. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed
mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures
all adjustments. Alignment holes and markings allow fixture to be pre-set
prior to installation.
9. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30"
long and lock securely into position. Built-in locking tabs provide positive attach-
ment to common T-bar systems. Self-centering feature simplifies installation in
24" O.C. grid systems. Attaches to steel or wood joists without accessories.
10.Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).
Accessible from below for inspection and/or replacement without tools.
11.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
12.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18
non-consumer equipment, shut-down circuit at end of lamp life, sound rating "A",
-5°F minimum starting temperature, Type 1 outdoor rating.
Electrical (cont)
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 0.67/0.28 78
100W MH M90/M140 120/277 0.90/0.43 110
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting
temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 1.90/0.80 94
100W MH M90/M140 120/277 2.40/1.10 125
Options and Accessories
Auxiliary: Add suffix Ato Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“.
Emergency Lamp: Add suffix Eto Reflector Trim and Frame In Kit. See
Spec.Sheet “E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame In Kit (F1=120V, F2=277V)
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA (magnetic ballast only), I.B.E.W.
For 100W electronic, install fixtures with minimum spacing: 2 feet from
center-to-center of adjacent luminaries; 1/2 inch from top of luminaire to over-
head building member; 1 foot from luminaire center to side building member.
Calculite®HID Downlight C7E17VW
Page 2 of 2 7" Aperture, ED17 (Enclosed), Ceramic Metal halide, Wide Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Job Information Type:
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62
1 .71 .69 .68 .66 .68 .65 .65 .63 .63 .61 .58
2 .67 .65 .63 .61 .64 .60 .62 .59 .60 .57 .55
3 .64 .61 .58 .56 .60 .55 .58 .55 .57 .54 .52
4 .61 .57 .54 .52 .57 .51 .55 .51 .54 .50 .49
5 .59 .54 .50 .48 .53 .48 .52 .47 .51 .47 .46
6 .56 .51 .47 .45 .50 .45 .49 .44 .48 .44 .43
7 .53 .47 .44 .42 .47 .41 .46 .41 .45 .41 .40
8 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37
9 .47 .42 .38 .35 .41 .35 .41 .35 .40 .35 .34
10 .45 .39 .35 .33 .39 .33 .38 .33 .38 .33 .32
LUMINAIRE INPUT WATTS = 78.0
ANGLE MEAN CP LUMENS
0 3077
5 3138 298
10 3124
15 3095 861
20 2830
25 2407 1111
30 1960
35 1523 949
40 1036
45 609 461
50 130
55 7 33
60 1
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
70W ED17 (ENCLOSED) PHILIPS CMH, LUMEN RATING = 6000 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 34796
55 475
65 0
75 0
85 0
** EFFICIENCY = 61.9% ** CERTIFIED TEST REPORT NO. 2412FR, DATE: JAN 12, 2004
SC = 1.0 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2269 37.83 61.13
0-40 3218 53.64 86.69
0-60 3712 61.87 99.99
0-90 3712 61.88 100
40-90 494 8.24 13.31
60-90 0 0 0.01
90-180 0 0 0
0-180 3712 61.88 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
1,500
750
2,250
3,000
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62
1 .70 .69 .67 .66 .68 .65 .65 .63 .63 .61 .58
2 .67 .65 .63 .61 .64 .60 .62 .59 .60 .57 .55
3 .64 .61 .58 .56 .60 .55 .58 .54 .57 .54 .52
4 .61 .57 .54 .52 .57 .51 .55 .51 .54 .50 .49
5 .58 .54 .50 .48 .53 .48 .52 .47 .51 .47 .46
6 .56 .51 .47 .45 .50 .45 .49 .44 .48 .44 .43
7 .53 .47 .44 .42 .47 .41 .46 .41 .45 .41 .40
8 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37
9 .47 .42 .38 .35 .41 .35 .41 .35 .40 .35 .34
10 .45 .39 .35 .33 .39 .33 .38 .33 .38 .33 .32
LUMINAIRE INPUT WATTS = 110.0
ANGLE MEAN CP LUMENS
0 4614
5 4705 446
10 4685
15 4641 1291
20 4244
25 3609 1667
30 2940
35 2283 1423
40 1553
45 912 691
50 195
55 9 48
60 1
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
100W ED17 (ENCLOSED) PHILIPS CMH, LUMEN RATING = 9000 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 52135
55 639
65 0
75 0
85 0
** EFFICIENCY = 61.8% ** CERTIFIED TEST REPORT NO. 2509FR , DATE: MAR 3, 2004
SC = 1.0 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3403 37.82 61.15
0-40 4826 53.62 86.71
0-60 5565 61.84 100
0-90 5565 61.84 100
40-90 739 8.22 13.29
60-90 0 0 0
90-180 0 0 0
0-180 5565 61.84 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
2,250
1,125
3,375
4,500

Other Lightolier Light Fixture manuals

Lightolier Lytespan 8605WH User manual

Lightolier

Lightolier Lytespan 8605WH User manual

Lightolier GUARDSMAN GV4WB332 User manual

Lightolier

Lightolier GUARDSMAN GV4WB332 User manual

Lightolier ProSpec 37100 User manual

Lightolier

Lightolier ProSpec 37100 User manual

Lightolier Soli 48022ALU User manual

Lightolier

Lightolier Soli 48022ALU User manual

Lightolier Calculite ProSpec PA3H3070 User manual

Lightolier

Lightolier Calculite ProSpec PA3H3070 User manual

Lightolier Lytespan 22WW4 User manual

Lightolier

Lightolier Lytespan 22WW4 User manual

Lightolier Decorative Visor 1 40618U User manual

Lightolier

Lightolier Decorative Visor 1 40618U User manual

Lightolier Calculite ProSpec PB3A1175 User manual

Lightolier

Lightolier Calculite ProSpec PB3A1175 User manual

Lightolier Lytespan 8258WH User manual

Lightolier

Lightolier Lytespan 8258WH User manual

Lightolier Lytecaster 604MR User manual

Lightolier

Lightolier Lytecaster 604MR User manual

Lightolier Calculite ProSpec PB3H3070 User manual

Lightolier

Lightolier Calculite ProSpec PB3H3070 User manual

Lightolier Calculite ProSpec PB4H3039 User manual

Lightolier

Lightolier Calculite ProSpec PB4H3039 User manual

Lightolier 9” PENDALYTE SERIES Instruction Manual

Lightolier

Lightolier 9” PENDALYTE SERIES Instruction Manual

Lightolier ProSpec 26383 User manual

Lightolier

Lightolier ProSpec 26383 User manual

Lightolier Lytecaster 2045 User manual

Lightolier

Lightolier Lytecaster 2045 User manual

Lightolier Lytespan DRL35 User manual

Lightolier

Lightolier Lytespan DRL35 User manual

Lightolier RADIANCE PENDANT FIXTURES Guide

Lightolier

Lightolier RADIANCE PENDANT FIXTURES Guide

Lightolier Calculite 7026AO User manual

Lightolier

Lightolier Calculite 7026AO User manual

Lightolier Brisa FC21U_3d User manual

Lightolier

Lightolier Brisa FC21U_3d User manual

Lightolier 6700S2UEMNY User manual

Lightolier

Lightolier 6700S2UEMNY User manual

Lightolier SL301A User manual

Lightolier

Lightolier SL301A User manual

Lightolier Paraplus II PPH2G8FW2FT User manual

Lightolier

Lightolier Paraplus II PPH2G8FW2FT User manual

Lightolier Tangent FXT4P User manual

Lightolier

Lightolier Tangent FXT4P User manual

Lightolier Calculite 8022WW User manual

Lightolier

Lightolier Calculite 8022WW User manual

Popular Light Fixture manuals by other brands

Triarch 32113 installation instructions

Triarch

Triarch 32113 installation instructions

Ningbo GU10 W 5W 120V manual

Ningbo

Ningbo GU10 W 5W 120V manual

Rebel Light ZAR0475 user manual

Rebel Light

Rebel Light ZAR0475 user manual

Westinghouse W-024 owner's manual

Westinghouse

Westinghouse W-024 owner's manual

Beamz LCB99 LED BAR user manual

Beamz

Beamz LCB99 LED BAR user manual

Challenger SLFLEDWIFI Quick setup guide

Challenger

Challenger SLFLEDWIFI Quick setup guide

EuroLite LED BRK-12 TCL user manual

EuroLite

EuroLite LED BRK-12 TCL user manual

Little Giant LED-L instructions

Little Giant

Little Giant LED-L instructions

Lightmybricks 21339 installation guide

Lightmybricks

Lightmybricks 21339 installation guide

Show Tec Magic Icecycle user manual

Show Tec

Show Tec Magic Icecycle user manual

Show Tec ACT Fresnel 50 WW manual

Show Tec

Show Tec ACT Fresnel 50 WW manual

Etec ML108 manual

Etec

Etec ML108 manual

FOS Technologies Luminus NANO user manual

FOS Technologies

FOS Technologies Luminus NANO user manual

mr. steam MS Chroma operating instructions

mr. steam

mr. steam MS Chroma operating instructions

STUDIODUE SLIMBAR SB PILOT 1615 user manual

STUDIODUE

STUDIODUE SLIMBAR SB PILOT 1615 user manual

MegaLite drama z fresnel 200 user manual

MegaLite

MegaLite drama z fresnel 200 user manual

Lightmybricks LEGO UCS IMPERIAL SHUTTLE 10212 installation guide

Lightmybricks

Lightmybricks LEGO UCS IMPERIAL SHUTTLE 10212 installation guide

Claypaky Alpha Spot HPE 700 instruction manual

Claypaky

Claypaky Alpha Spot HPE 700 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.