manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. Light Fixture
  8. •
  9. Lightolier Calculite Matrix 4X9 User manual

Lightolier Calculite Matrix 4X9 User manual

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • A0409
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Calculite® Matrix®Open Downlight 4X9
Page 1 of 3 4 1/2" X 9" Rectangular Aperture (1) 26W Quad / 32/42 Triple 2-Cell Parabolic Louver
5
7
5 1/2"
10 1/4"
9"
4 2 31 6
4 1/2"
5 3/4"
1 1/4" Max.
Ceiling Thickness
12 3/8"
9 5/8"
5 7/8"
9 9/16"
5"
Top View
Features
1. Reflector Trim: Pre-finished aluminum with low iridescence clear finish. 55°
visual and reflected cutoff. Overlap flange accommodates different ceiling
types. Precision mitered flange corners.
2. Upper Reflector: High efficiency, 97%, Specular Clear.
3. Housing: 22 Ga. galvanized formed steel. Centerline notches and holes
for consistent alignment of multiple fixtures. Accommodates ceilings up to
1 1/4" thick.
4. Ballast Assembly: Door-mounted for easy service, allows replacement from
inside of fixture.
5. Torsiontite Springs: Precision-tooled steel springs secure reflector trim
to housing for quick tool-less installation. Positive tension holds flange tight
against ceiling.
6. J-Box: 14 Ga. galvanized steel. Accessible from inside and outside of the
fixture. Outside J-box door is hinged for easy access.
7. Mounting Brackets: 16 Ga. steel. Adjustable from inside fixture. Utilize
3/4" or 1 1/2" lathing channel, 1/2" EMT, or optional mounting bars.
Options & Accessories
Chicago Plenum with Fuse (slow blow): add LCF suffix to frame-in kit, con-
sult factory for specifications.
Emergency: add EM suffix to frame-in kit, consult factory for specifications.
Option not available in the 57W version.
Mounting Bars / T-Bar Anchor Clips: See specification sheet “MBA".
Electrical
UL Listed for through circuit wiring with max of (8) No. 12 AWG, 90° C supply
conductors.
Note: For complete ballast data and lamp/ballast compatibility refer to
“Ballast" specification sheet.
General
UL listed for damp locations. I.B.E.W. Union Made.
Specular Clear finish (CL) reflector trims meet IES RP-1 practice.
Ceiling Cutout: 5 1/8" L X 9 5/8" W
Trim Kits Frame-In Kits
Reflector
Trims Finish / Flange Frame-In Kits Type Ballast Input
Voltage
Quad Tube
Wattage
Triple Tube
Wattage Length Width Height
4X9CLW Specular Clear / White 4X9142HU Non-IC Electronic 120/277V 26W 32/42W 12 1/2" 9 1/2" 5 3/4"
4X9CLP Specular Clear / Polished 4X9142HUEM Non-IC Electronic - Emergency 120/277V 26W 32/42W 12 1/2" 11" 5 3/4"
4X9CCLW Comfort Clear / White 4X9142HJUM7 Non-IC Mark 7®Dimming 120/277V 26W 32/42W 12 1/2" 9 1/4" 5 3/4"
4X9CCLP Comfort Clear / Polished 4X9142HJ1MX Non-IC Mark 10®Dimming 120V 26W 32/42W 12 1/2" 9 1/4" 5 3/4"
4X9CCDW Comfort Clear Diff. / White 4X9142HJ2MX Non-IC Mark 10®Dimming 277V 26W 32/42W 12 1/2" 9 1/4" 5 3/4"
4X9CCDP Comfort Clear Diff. / Polished
4X9CCGP Clear Corrugated / Self Flange
4X9WHW White / White
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • A0409
Calculite® Matrix®Open Downlight 4X9
Page 2 of 3 4 1/2" X 9" Rectangular Aperture (1) 26W Quad / 32/42 Triple 2-Cell Parabolic Louver
Job Information Type:
1 .76 .74 .72 .75 .73 .71 .72 .70 .69 .69 .68 .67 .67 .66 .65 .64
2 .70 .67 .64 .69 .66 .63 .66 .64 .62 .64 .62 .61 .62 .61 .59 .58
3 . 64 .60 .57 .63 .59 .56 .61 .58 .55 .59 .57 .54 .58 .56 .54 .52
4 .59 .54 .51 .58 .54 .50 .56 .53 .55 .55 .52 .49 .53 .51 .49 .47
5 .53 .49 .45 .53 .48 .45 .51 .47 .44 .50 .47 .44 .49 .46 .44 .42
6 .49 .44 .40 .48 .43 .40 .47 .43 .40 .46 .42 .39 .45 .41 .39 .38
7 .44 .39 .35 .43 .38 .35 .42 .38 .35 .41 .37 .34 .40 .37 .34 .33
8 .39 .34 .31 .39 .34 .31 .38 .34 .31 .37 .33 .30 .37 .33 .30 .29
9 .36 .30 .27 .35 .30 .27 .34 .30 .27 .34 .29 .26 .33 .29 .26 .25
10 .32 .27 .23 .31 .27 .23 .31 .26 .23 .30 .26 .23 .30 .26 .23 .22
32W Triple Tube, Specular Clear Reflector Trim
One Philips lamp, 2400 lumens
Test Report 1761FR Apr. 4, 2002
EFFICIENCY = 69.3% Spacing Criterion: Along = 1.7Across = 1.5
% Effective Ceiling Cavity Reectance
1 .61 .60 .58 .60 .59 .57 .58 .56 .56 .55 .55 .54 .54 .53 .52 .51
2 .56 .54 .52 .55 .53 .51 .54 .52 .50 .52 .51 .49 .50 .49 .48 .47
3 .52 .49 .46 .51 .48 .46 .50 .47 .45 .48 .46 .45 .47 .45 .44 .43
4 .48 .44 .42 .47 .44 .41 .46 .43 .41 .45 .42 .41 .44 .42 .40 .39
5 .44 .40 .38 .43 .40 .37 .42 .39 .37 .41 .39 .37 .40 .38 .36 .35
6 .40 .36 .34 .40 .36 .34 .39 .36 .33 .38 .35 .33 .37 .35 .33 .32
7 .37 .33 .30 .36 .32 .30 .35 .32 .30 .35 .32 .29 .34 .31 .29 .28
8 .33 .29 .27 .33 .29 .27 .32 .29 .26 .32 .29 .26 .31 .28 .26 .25
9 .30 .26 .24 .30 .26 .24 .29 .26 .23 .29 .26 .23 .28 .25 .23 .22
10 .27 .24 .21 .27 .24 .21 .27 .23 .21 .26 .23 .21 .26 .23 .21 .20
ROOM CAVITY RATIO
cu
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
80 70 50 30 10 0
26W Quad Tube, Specular Clear Reflector Trim
One Sylvania lamp, 1800 lumens
ZONAL LUMENS AND PERCENTAGES
Zone Lumens % Lamp % Luminaire
0-30 406 22.58 10.72
0-40 680 37.81 68.17
0-60 995 55.31 99.71
0-90 998 55.47 100.00
0 439 439 439 439 439
5 457 450 435 437 429 42
10 466 448 443 462 459
15 477 455 477 510 510 136
20 495 472 513 524 492
25 485 478 532 489 467 228
30 475 474 488 503 450
35 432 478 443 414 356 274
40 349 450 424 350 397
45 256 350 361 344 296 243
50 144 203 248 182 119
55 38 60 106 43 27 72
60 3 5 19 3 2
65 1 1 1 1 1 3
70 1 1 0 0 1
75 0 0 0 0 0 0
80 0 0 0 0 0
85 0 0 0 0 0 0
90 0 0 0 0 0
Test Report 1762FR Apr. 4, 2002
Angle Along 22.5 45 67.5 Across Lumens
CANDLEPOWER SUMMARY
EFFICIENCY = 55.5% Spacing Criterion: Along = 1.5Across = 1.3
% Effective Ceiling Cavity Reectance
ROOM CAVITY RATIO
cu
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
80 70 50 30 10 0
20% Floor Cavity Reectance 20% Floor Cavity Reectance
ZONAL LUMENS AND PERCENTAGES
Zone Lumens % Lamp % Luminaire
0-30 586 24.43 35.24
0-40 1066 44.42 64.10
0-60 1658 69.09 99.70
0-90 1663 69.30 100.00
0 563 563 563 563 563
5 580 582 578 575 567 56
10 608 608 608 643 658
15 640 631 683 706 691 189
20 702 691 719 691 681
25 765 775 740 675 705 342
30 827 874 786 726 738
35 782 861 842 705 605 480
40 658 779 858 619 538
45 505 607 725 610 458 449
50 341 386 499 407 221
55 85 113 169 114 50 143
60 5 8 33 9 4
65 2 2 3 2 2 5
70 1 1 1 1 1
75 0 0 0 0 0 0
80 0 0 0 0 0
85 0 0 0 0 0 0
85 0 0 0 0 0
90 0 0 0 0 0
Angle Along 22.5 45 67.5 Across Lumens
CANDLEPOWER SUMMARY
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • A0409
Calculite® Matrix®Open Downlight 4X9
Page C of 3 4 1/2" X 9" Rectangular Aperture (1) 26W Quad / 32/42 Triple 2-Cell Parabolic Louver
Job Information Type:
% Effective Ceiling Cavity Reectance
1 .72 .71 .69 .71 .69 .68 .68 .67 .66 .66 .65 .64 .64 .63 .62 .61
2 .67 .64 .61 .66 .63 .61 .63 .61 .59 .62 .60 .58 .60 .58 .57 .56
3 .61 .58 .55 .60 .57 .54 .59 .56 .53 .57 .55 .52 .55 .53 .52 .51
4 .56 .52 .49 .56 .52 .49 .54 .51 .48 .53 .50 .48 .51 .49 .47 .46
5 .52 .47 .44 .51 .47 .44 .50 .46 .43 .48 .45 .43 .47 .45 .42 .41
6 .47 .42 .39 .46 .42 .39 .45 .42 .39 .44 .41 .38 .43 .40 .38 .37
7 .43 .38 .35 .42 .38 .34 .41 .37 .34 .40 .37 .34 .39 .36 .34 .33
8 .39 .34 .30 .38 .34 .30 .37 .33 .30 .37 .33 .30 .36 .32 .30 .29
9 .35 .30 .27 .35 .30 .27 .34 .30 .27 .33 .29 .26 .32 .29 .26 .25
10 .32 .27 .24 .31 .27 .24 .31 .26 .23 .30 .26 .23 .29 .26 .23 .22
42W Triple Tube, Specular Clear Reflector Trim
One Philips lamp, 3200 lumens
ZONAL LUMENS AND PERCENTAGES
Zone Lumens % Lamp % Luminaire
0-30 803 25.10 38.00
0-40 1402 43.84 66.36
0-60 2107 65.87 99.70
0-90 2113 66.06 100.00
0 792 792 792 792 792
5 812 812 810 812 802 79
10 835 838 866 926 939
15 890 895 973 1010 982 266
20 922 959 1028 966 939
25 939 1019 1006 952 978 458
30 961 1054 1003 1043 1021
35 896 1060 1027 929 828 600
40 762 955 976 724 781
45 594 761 854 701 646 536
50 344 464 600 405 285
55 80 144 243 115 70 169
60 7 11 45 8 5
65 2 2 3 2 2 6
70 1 1 1 1 1
75 1 1 1 0 0 0
80 0 0 0 0 0
85 0 0 0 0 0 0
90 0 0 0 0 0
Test Report 1760FR Apr. 4, 2002
Angle Along 22.5 45 67.5 Across Lumens
CANDLEPOWER SUMMARY
EFFICIENCY = 66.1% Spacing Criterion: Along = 1.6Across = 1.5
57W Triple Tube, Specular Clear Reflector Trim
One Sylvania lamp, 4300 lumens
ZONAL LUMENS AND PERCENTAGES
Zone Lumens % Lamp % Luminaire
0-30 1277 29.72 41.07
0-40 2098 48.81 67.45
0-60 3105 72.21 99.79
0-90 3111 72.36 100.00
0 1474 1474 1474 1474 1474
5 1488 1497 1515 1532 1535 145
10 1490 1531 1597 1642 1651
15 1469 1522 1641 1588 1551 443
20 1409 1504 1523 1598 1587
25 1361 1469 1490 1603 1559 690
30 1324 1418 1465 1461 1365
35 1244 1329 1380 1267 1218 821
40 1100 1248 1183 1153 1339
45 887 1037 1038 1112 1069 761
50 554 649 749 654 508
55 145 219 333 176 105 246
60 7 13 61 10 6
65 1 1 3 2 1 6
70 0 0 0 0 0
75 0 0 0 0 0 0
80 0 0 0 0 0
85 0 0 0 0 0 0
90 0 0 0 0 0
Test Report 1759FR Apr. 4, 2002
Angle Along 22.5 45 67.5 Across Lumens
CANDLEPOWER SUMMARY
EFFICIENCY = 72.4% Spacing Criterion: Along = 1.3Across = 1.3
ROOM CAVITY RATIO
cu
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
80 70 50 30 10 0
% Effective Ceiling Cavity Reectance
1 .79 .78 .76 .78 .76 .75 .75 .74 .72 .72 .71 .70 .70 .69 .68 .67
2 .73 .70 .68 .72 .69 .67 .70 .67 .65 .68 .66 .64 .66 .64 .63 .61
3 .67 .64 .60 .66 .63 .60 .65 .61 .59 .63 .60 .58 .61 .59 .57 .56
4 .62 .58 .54 .61 .57 .54 .60 .56 .53 .58 .55 .53 .57 .54 .52 .51
5 .57 .52 .49 .56 .52 .49 .55 .51 .48 .54 .50 .48 .53 .50 .47 .46
6 .52 .47 .44 .52 .47 .44 .51 .47 .43 .50 .46 .43 .49 .45 .43 .42
7 .48 .43 .39 .47 .42 .39 .46 .42 .39 .45 .41 .38 .44 .41 .38 .37
8 .43 .38 .35 .43 .38 .35 .42 .38 .35 .41 .37 .34 .40 .37 .34 .33
9 .40 .34 .31 .39 .34 .31 .38 .34 .31 .38 .33 .31 .37 .33 .30 .29
10 .36 .31 .27 .36 .31 .27 .35 .30 .27 .34 .30 .27 .34 .30 .27 .26
ROOM CAVITY RATIO
cu 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
80 70 50 30 10 0
20% Floor Cavity Reectance 20% Floor Cavity Reectance

This manual suits for next models

13

Other Lightolier Light Fixture manuals

Lightolier Soli 48022ALU User manual

Lightolier

Lightolier Soli 48022ALU User manual

Lightolier Lytespan 7531 User manual

Lightolier

Lightolier Lytespan 7531 User manual

Lightolier Calculite C4MRD CCDW User manual

Lightolier

Lightolier Calculite C4MRD CCDW User manual

Lightolier HS Series User manual

Lightolier

Lightolier HS Series User manual

Lightolier Calculite ProSpec PB3P3075 User manual

Lightolier

Lightolier Calculite ProSpec PB3P3075 User manual

Lightolier SL203A User manual

Lightolier

Lightolier SL203A User manual

Lightolier Lytespan 8735 User manual

Lightolier

Lightolier Lytespan 8735 User manual

Lightolier Lytespan DRL35 User manual

Lightolier

Lightolier Lytespan DRL35 User manual

Lightolier Lytespan LCAWTSX User manual

Lightolier

Lightolier Lytespan LCAWTSX User manual

Lightolier LL4MF8LX254 User manual

Lightolier

Lightolier LL4MF8LX254 User manual

Lightolier Lytecaster 1004F26ES User manual

Lightolier

Lightolier Lytecaster 1004F26ES User manual

Lightolier CA3FMR SERIES User manual

Lightolier

Lightolier CA3FMR SERIES User manual

Lightolier Calculite C4X4MRD User manual

Lightolier

Lightolier Calculite C4X4MRD User manual

Lightolier ProSpec 26070 User manual

Lightolier

Lightolier ProSpec 26070 User manual

Lightolier VP Parabolic VPA2G12PP317 User manual

Lightolier

Lightolier VP Parabolic VPA2G12PP317 User manual

Lightolier 8279EN User manual

Lightolier

Lightolier 8279EN User manual

Lightolier STA 1'x4' 1 LAMP User manual

Lightolier

Lightolier STA 1'x4' 1 LAMP User manual

Lightolier QVS2GPFOS232 User manual

Lightolier

Lightolier QVS2GPFOS232 User manual

Lightolier CTS3_FLNG Instruction Manual

Lightolier

Lightolier CTS3_FLNG Instruction Manual

Lightolier Luminosities 40888 User manual

Lightolier

Lightolier Luminosities 40888 User manual

Lightolier SL200A User manual

Lightolier

Lightolier SL200A User manual

Lightolier Lytecaster 1022 User manual

Lightolier

Lightolier Lytecaster 1022 User manual

Lightolier Lytespan 9175N User manual

Lightolier

Lightolier Lytespan 9175N User manual

Lightolier ProSpec 26030W User manual

Lightolier

Lightolier ProSpec 26030W User manual

Popular Light Fixture manuals by other brands

Schüco Skala 553789.03 Assembly instruction

Schüco

Schüco Skala 553789.03 Assembly instruction

Philips VLX user manual

Philips

Philips VLX user manual

Philips Lytespan 23S20T4 specification

Philips

Philips Lytespan 23S20T4 specification

Microh LED ARC-18 user manual

Microh

Microh LED ARC-18 user manual

Light Sky Tornado Series user manual

Light Sky

Light Sky Tornado Series user manual

ETC Source Four Revolution user manual

ETC

ETC Source Four Revolution user manual

XanLite LSAK1PIRVB user manual

XanLite

XanLite LSAK1PIRVB user manual

netvox ZC07 user manual

netvox

netvox ZC07 user manual

RSA Lighting Combolight LV1100 Specifications

RSA Lighting

RSA Lighting Combolight LV1100 Specifications

RUTEC VARDAflex 3inONE-60 quick start guide

RUTEC

RUTEC VARDAflex 3inONE-60 quick start guide

IKEA DUGGREGN manual

IKEA

IKEA DUGGREGN manual

RSA Lighting Combo Mini brochure

RSA Lighting

RSA Lighting Combo Mini brochure

LIVARNO home 423269 2201 Operating and safety instructions

LIVARNO home

LIVARNO home 423269 2201 Operating and safety instructions

MiLAN Wire Series Assembly instructions

MiLAN

MiLAN Wire Series Assembly instructions

Finelite S12 installation instructions

Finelite

Finelite S12 installation instructions

Code 3 MEGAFLEX Series Installation and operation instruction

Code 3

Code 3 MEGAFLEX Series Installation and operation instruction

EuroLite BSL-10 user manual

EuroLite

EuroLite BSL-10 user manual

Philips 69101-30-PH Specification sheet

Philips

Philips 69101-30-PH Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.