Lincoln LFC 3000 User manual

Page
Section - F60 - 2
Form 403082
June 2002
LFC 3000 Users Manual
Series A

Page Number - 2
LFC 3000 Users Manual
Series A
Form 403082
IMPORTANT SAFETY INSTRUCTIONS.
1. Before installing or using this product, please read the
instruction manual thoroughly.
2. Unpacking: Please check that the product is complete
and free from any damage
3. Only qualified indi idual should install and/or repair this
product.
4. Unplug the LFC3000 from the electrical outlet before you
clean it.
Use a damp cloth for cleaning and do not use liquid or
aerosol cleaners.
5. Do not place the LFC3000 on an unstable surface that
may allow the unit to fall.
6. Ne er place the LFC3000 near or o er a radiator or heat
register.
7. Use the type of power source indicated on the label (AC
power). If you are not sure of the type of power a ailable,
consult your supplier or local electric company.
8. The LFC3000 must be equipped with a plug ha ing a
third (grounding) pin, which fits only into a grounding-
type outlet. This is a safety feature. LFC3000 should not
be used without a properly grounded outlet. Failure to
properly ground the LFC3000 may cause damage to the
unit or the data stored.
9. Do not put the LFC3000 where the cord will be walked
on.
10. An extension cord is not recommended for use with the
LFC3000.
If you use an extension cord, make sure that the total of
the ampere ratings on the products plugged into the
extension cord does not exceed the extension cords
ampere rating. Also make sure that the total of all
products plugged into the wall outlet does not exceed
15 amperes.
11. Unplug the LFC3000 from the wall outlet and ha e it
repaired by a qualified ser ice person under the
following conditions:
A. When the power cord or plug is damaged or frayed.
B. If liquid has been spilled into it.
C. If it has been exposed to rain or water.
D. If it does not operate normally when the operating
instructions are followed. Adjust only those controls that
are co ered by the operating instructions since improper
adjustment of other controls may result in damage and
lose of data.
E. If it has been dropped or damaged.
If it exhibits a distinct change in performance, indicating
a need for ser ice.
Table of Contents
Safety Instructions..........................................................................2
Description......................................................................................3
Memory Protected..........................................................................3
Technical Data................................................................................4
User Menu.......................................................................................4
Super isor Menu............................................................................4
Customer Menu..............................................................................6
System Menu..................................................................................8
Transaction Codes......................................................................11
Flow Chart for Screens................................................................12
Failure to adhere to these safety instructions may result
in serious bodily injury or death.

Page Number - 3
Form 403082
LFC 3000 Users Manual
Series A
DESCRIPTION
The LFC 3000 is a modular fluid management/security
system for ser ice workshops. It pro ides the shop super i-
sor with a host of ser ices required for precise manage-
ment of an in entory of products such as oil and antifreeze.
The LFC 3000 maintains the in entory by controlling access
to hoses, precise metering of the products, and accurate
accounting.
A transaction ticket is printed upon completion of all transac-
tions and an in entory report showing all product le els is
a ailable to the super isor.
The LFC 3000 will keep up to 1900 transactions in its
protected memory. A transaction historic report keeps track
of all the transactions, classified by users, products or
hoses.
The modularity of the LFC 3000 makes it adaptable to your
existing workshop and upgradable in the future. It is
comprised of 1 to 8 I/O modules, 1 to 64 data entry keypads,
1 to 16 optional remote displays and 1 optional PC
interface.
The I/O module is the operating intelligence. Each I/O
module supports up to 8 counter inputs and controls up to 8
solenoid dri ers - this means that the LFC 3000 can operate
up to 64 hose reels all simultaneously. One I/O module can
communicate with 1 to 8 data entry keypads. The I/O module
also supports one additional output for acti ating or disacti-
ating the main air supply.
The data entry keypad pro ides access to the system for oil
monitoring and dispensing procedures. Configuration of
the system is also done from the keypad (for installations
without PC). The keypads are all alphanumerical and
equipped with a serial port to pro ide connection to a serial
printer.
The remote display has large 56 mm digits to isualize the
quantity currently dispensed.
The PC interface is a ailable as an option and offers
extended remote transaction memory, computer interfacing
and the possibility to control up to 24 I/O units - which
means 192 outlets. A complete management software
package is supplied with the PC interface. The software is
Windows compatible and does not require a dedicated PC.
To initiate a transaction, a personal identification number
(PIN) must be entered ia the data entry keypad. Any keypad
can communicate with any I/O module. A job number, a hose
number and the preset amount must be entered. The
technician then begins dispensing the product. The amount
of product dispensed is displayed on the remote display.
When a transaction ends, a transaction ticket is printed on
the printer, and the appropriate in entory is reduced by the
amount dispensed. Transactions will also end whene er
dispensing stops for a certain time period.
The transaction ticket contains all data rele ant to the
transaction including the job number, the product name, the
amount dispensed, the mechanics name, the hose used,
the type of transaction, the time and date and the remaining
in entory of the dispensed product.
The LFC 3000 controls up to 64 hoses and can maintain an
in entory of up to 8 tanks. The system can be configured for
use with pulse meters that are single channel or quadrature
(w&m appro ed).
Access to functions such as configuration and report
printing is restricted to different security le els; a super isor
code must be entered before these functions can be used.
The super isor can select the language that will be used
throughout the system.
MEMORY PROTECTED
The LFC 3000 is pro ided with a battery backed RAM to
store up to 1900 completed transactions to guard against
data loss in the e ent of a power failure.
Transaction ticket: Audit trail of all completed jobs
Stock le el: Stock le el of each product tank
with minimum stock le el
Product deli ery: Details of all deli eries entered
into the system, date and quantity -
and stock corrections.
Transaction reports: Product report - usage and totals
Hose reports - usage and totals
User report - usage and totals
All transactions - usage and totals
(data retrie ed from system
memory)
Alarm ticket: If a high le el warning switch is
fitted to the waste oil collection
tank, a ticket is printed
immediately as a warning
Tank low le el warning: When the minimum tank le el is
reached, a warning ticket is
printed
Job report: Report re iew by job number for
different grades against the same
job number and from one date to
another (PC le el only).
License plate report: Historic report by license plate
number (PC le el only)
Configuration: Keeps track of the system
configuration for reconfiguration
and after sales ser ice.
Note: All the abo e reports are a ailable to be printed
except where shown as PC le el only. When a PC
is incorporated, all reports can be iewed on
screen before printing.

Page Number - 4
LFC 3000 Users Manual
Series A
Form 403082
Enter Hose
_ 0
Enter the hoses number, which corresponds to your request.
Press ENTER
Product
(Products name)
The system confirms the products name dispensed on the
selected hose. Press ENTER
Enter quantity
6.7
(Optional Dispense mode: Pre-select or Free dispense)
Enter the desired quantity. Press ENTER
Dispense product
SUPERVISOR MENU
The Super isor menu is accessible through all the keypads
by entering the Super isor PIN Number. E ery 45 seconds
without use of the keypad, the display shows you the date &
time and resets the network. The factory PIN number for the
super isor menu is 9999.
Enter Pin No.
9999
Good orning
Supervisor
Supervisor enu
Start / Stop
The selection Start/Stop allows the super isor to restart the
system. ENTER
System State
Active
ENTER
Supervisor enu
Transaction Report
Upon request, the super isor can print the transactions
reports. These reports will gi e him precise history of fluids
dispensed and totals. All the reports are printed on the
report printer as configured in the system configuration
menu.
TECHNICAL DATA
Network specifications
The LFC 3000 operates with a CAN Bus network that uses two
wires and a shield.
System specifications
Keypads on a system 64 max.
I/O modules on a system 8 max.
Solenoid al es on a system 64 max.
Meters with single channel pulse transmitters 64 max.
Fluids on a system 8 max.
Number of operators 99 max.
Transaction log 1900 max.
Simultaneous dispenses 64 max.
Printers per system 64 max.
Power supply
The LFC 3000 operates on a 24 VDC oltage.
A power supply unit is included in the system - Voltage Input
90-120 Volts AC, 50/60 Hz single phase.
Default PIN Numbers
The factory PIN numbers are as follows:
Super isor Menu......................................................................9999
Customer Menu........................................................................1111
System Menu...........................................................................2222
USER MENU
The user menu is accessible through all the keypads. Only
the personal PIN code gi es
access to this menu.
Enter Pin No.
****
Good orning
(Users name)
Enter Job No.
.
Enter the number of the job, Press ENTER
Enter Reg. No.
.
(Optional)
Enter the ehicle plate number (Alphanumerical), Press
ENTER
Enter Reg. No.
.
(Optional)
Enter the ehicle mileage. Press ENTER

Page Number - 5
Form 403082
LFC 3000 Users Manual
Series A
sor PIN Number has been forgotten, it will be necessary to
reset the system. See Instruction Manual under Trouble-
shooting, Lost Super isor PIN.
ENTER
Supervisor pin
9999
ENTER
Supervisor enu
Set super PIN
ENTER
Confirm PIN
****
ENTER
Confirm PIN
Confirmed
ENTER
Supervisor enu
Clear transactions
ENTER
We ad ise you to clear regularly the transactions when you
use the system without PC: the transactions number is limit-
ed to 1900. Moreo er, when you print the report, you will ha e
the printing of all the transactions since the last Clear trans-
actions. Answering Yes will automatically clear all transac-
tions in the memory of the system. To a oid clearing transac-
tions by mistake, the system is proposing a No answer.
Using the down arrow will bring the Yes answer on the
screen.
ENTER
Clear Transactions
No
Down
ENTER
Are you sure?
No
Down
ENTER
Suggestion: print your transaction reports before clearing
transactions.
Transaction reports are a ailable:
By user Report by user (Enter the users number)
By hose Report by hose (Enter the hoses number)
By product Report by product (Enter the products
number)
All trans-
actions All Reports
Exit
Supervisor enu
Delivery Rep.
LFC 3000 prints a hard copy of all your stock modifications.
We recommend you to print this report after each product
deli ery entered in the system.
Supervisor enu
Stock Level Rep.
Prints the stock and the minimum le els for all the config-
ured tanks.
Supervisor enu
Product Delivery
Enter here your new oil deli eries. The new stock will be
calculated automatically. Suggestion: Print a deli ery report
after entering deli eries.
Use Up / Down key to select the desired tank. ENTER
Supervisor enu
New Stock Level
If you want to modify the stock le el:
ENTER
New Stock Level
Tank 1 = 200
New Stock Level
300 lts
Supervisor enu
Set Date / Time
ENTER
Date 17-05-02
Time 15:09
In a multi I/O system, this parameter must be the same on
each I/O. E ery 45 seconds without use of the keypad, the
display shows you the date & time and reset the network.
Supervisor enu
Set super PIN
This prompt is used to change the Super isor PIN Number.
Only numerical PIN is accepted by the system. If the super i-

Page Number - 6
LFC 3000 Users Manual
Series A
Form 403082
CUSTOMER MENU
The Customer Configure Menu is accessible though all the
keypads. At the initialization of the system or when modifi-
cations are done on this menu, the data is automatically
updated at the other keypads through the network. It is not
necessary to configure all the keypads separately.
Customer enu
Products
All the fluids controlled by the system can be identified in
alphanumerical characters. In certain installations, the
same product can be pumped from different tanks (maxi-
mum 8 tanks). The LFC 3000 allows you to manage these
tanks separately to control their respecti e stock le el.
Assign the tank from which the product will be pumped.
Enter
Tank Number 1
Enter the tank number
ENTER
Product 1
otor Oil
Use Up / Down key to select the product number
ENTER
Enter the products identification by using the alphanumeric
keypad
ENTER
The system goes back to the prompt Products
Customer enu
Hose
All your dispensing points (hoses) must be linked to the tank
it is dispensing from.
ENTER
Enter Hose
01
Enter the hose number
ENTER
Enter Tank
01
Enter the tank number
ENTER
The system will confirm the name of the product configured
for erification;
Select Product
otor Oil
ENTER
Enter hose 00 to exit
Supervisor enu
Add New User
Up to 99 users can be stored in the system. Any 4 digit PIN
numbers can be assigned to an operator. It is recommend-
ed that the super isor keep a list of the PIN numbers in
case he needs to remo e one of them. Two users cannot
ha e the same PIN Number.
ENTER
New User Pin
****
ENTER
New User Name
(User name)
ENTER
New User Name
User added
Supervisor enu
Remove User
ENTER
Enter Ex-PIN
****
ENTER
Enter Ex-PIN
User deleted
The user will be deleted from the system.
Supervisor enu
Customer Config.
ENTER
Customer cfg. PIN
1111
Access to the customer security le el. Factory PIN number for
customer menu is 1111.
Supervisor enu
Exit
ENTER
Return to User Screen

Page Number - 7
Form 403082
LFC 3000 Users Manual
Series A
Dispense ode
Pre-Select - Free Dispense
Customer enu
Odometer & Reg.
With the LFC 3000 you can store the odometer reading and
the license plate number of the ehicles maintained in the
garage. This information will appear on the transaction
ticket;
ENTER
Odometer & Reg.
Yes
Use Up / Down keys to select
The keypad will always ask the operator to store the
odometer and registration plate of the ehicle
corresponding to the job number.
Odometer & Reg.
No
The function will not be acti ated.
Customer enu
Initial Timeout
The initial time-out is the time between the alidation of the
transaction datas on the keypad and the opening of the
solenoid al e corresponding to the selected hose. Enter
the maximum number of seconds necessary before starting
the operation.
In a multi I/O system without PC, this parameter must
programmed and be the same and on each I/O.
ENTER
Initial Timeout
06
Customer enu
Inactive Timeout
The inacti e timeout is the period between the last pulse
recei ed by the system and the closing of the solenoid. The
LFC 3000 will close the transaction if the time between 2
pulses reaches the inacti e-time configured in the system.
It is isualized that the operator has started to fill the ehicle
with oil and that he has stopped the dispense before the
pre-set quantity has been reached or because he is work-
ing in the free dispense mode. When choosing this dura-
tion, bear in mind that this should be long enough for your
worker to erify the oil le el on the dip stick. Enter the
maximum number of seconds needed.
Customer enu
Warn Level
A minimum stock le el must be set for each tank. All fluids
dispenses will automatically be deducted from the respecti e
tank stock. When the stock le el in the tank reaches the warn-
ing le el, a warning reordering message will automatically be
printed on the report printer.
ENTER
Use Up / Down arrow key to select the tank
Warn Level
Tank 1 = _ _ _ _
ENTER
Warn Level
_ _ _ _ 0
Enter the minimum stock le el
ENTER
Warn Level
400
Customer enu
Stop Level
In addition to the minimum le el, the LCF 3000 offers the
ability to set up stop le els for each tank, pre enting
dispenses of the selected product when the le el in the tank
is under the stop le el limit. This will pre ent air to enter in
the oil line and pre ent any risk of impurities entering the
line as well.
ENTER
Stop Level
Tank 1 = _ _ _ _ 0
Choose the tank you want to configure.
ENTER
New Stop Level
_ _ _ _ 0
Customer enu
Dispense ode
The LFC 3000 offers the possibility for the operator to
dispense oil in Pre-Select or in free dispense mode. In Pre-
select mode, the system will not authorizes any dispense
without a pre-selected quantity of fluid. In free dispense, the
system will authorize dispenses without pre-selection of any
quantity.
The system will close the transaction when the inacti e
time-out has been reached.
ENTER
Use Up / Down key to select the mode.

Page Number - 8
LFC 3000 Users Manual
Series A
Form 403082
Inactive Timeout
120
In a multi I/O system without PC, this parameter must
programmed and must be the same on each I/O.
Customer enu
Set Language
ENTER
Use Up / Down key to select the language.
LFC 3000 is a multi language system. The default
language is British English.
To change to American English, you must enter US0011.
This will also change the unit of measurement from liters to
quarts.
Customer enu
Set Customer PIN
This prompt is used to change the Customer PIN number.
Only numerical PIN is accepted by the system.
If the Customer PIN has been forgotten, it will be necessary
to reset the system and re-configure. See Instruction
Manual, under Troubleshooting, Lost Super isor Pin.
ENTER
Customer Cfg PIN
****
ENTER
Confirm PIN
****
Confirm PIN
Confirmed
System enu
Diagnostics
As a support for the installer and after sales ser ices, LFC
3000 pro ides a diagnostic report:
- the configuration for the installation parameters
- the names of the products
- the number of the users, their names and their
PIN codes
- the hoses, tanks, products names, displays and
corrections factors
We ad ise you to print this diagnostic after each installation.
Customer enu
Configure System
ENTER
System Cfg PIN
2222
Access to the System Configuration installer le el. The
factory PIN number is 2222 for the System Menu.
Customer enu
Exit
ENTER
Return to the super isor menu prompt. To return to the User
Screen, press ENTER again.
SYSTEM MENU
The System Configuration Menu is accessible through all
the keypads. The modified data is automatically updated at
the other keypads through the network. It is not necessary to
configure all the keypads separately. Only ticket (A&B)
printers must be configured on each keypad.
System enu
Test ode
ENTER
Use Up / Down key to select the test.
-Test A: test the opening/closing for each solenoid.
The test A from a keypad is only alid for the
solenoid al es connected on the I/O unit
communicating with this keypad.
-Test B: factory use only
-Test C: test to confirm the address of each large character
remote display
display address 0: random figures
display address 1: figures 000.1
display address 2: figures 000.2
Etc
-FLT FLT FLT FLT or OK OK OK OK: this test is only alid for
quadrature pulsers.
You ha e the possibility to test a maximum of 4 quadrature
pulsers connected on the I/O Unit.
The position of the message indicates where the position of
the pulser is.
An OK message indicates that the quadrature pulser is not
connected.
If you connect single pulsers, a FLT message will appear.
-none
System enu
Display Allocation
The LFC 3000 offers the use of remote displays for an easy
isualization of the oil dispensed by the worker. This screen
allows you to program in the system on which display the
worker wants to isualize his dispenses. One display can
be used for multi hose reels.

Page Number - 9
Form 403082
LFC 3000 Users Manual
Series A
Report Address
I/O Control
ENTER: The report printer is connected to an I/O unit
(ID=0). Use Up / Down key to select
Report Address
Keypad x
ENTER: The report printer is connected on the keypad
number X.
Use Up / Down key to select until you ha e the correct
address.
ENTER
Report Address
None
ENTER: There is no report printer on the system.
Use Up/Down keys to select.
ENTER
System enu
Set Ticket A Adr.
To fulfill all the needs of the garage super isors, LFC 3000
offers the flexibility to print the transaction tickets on different
printers. All the printers must be connected through the
serial port and be Epson emulated. This instruction must
be done on EACH keypad.
The Factory default setting is Ticket A address on Keypad 0.
ENTER
Ticket A Address
I/O Control Unit
ENTER: The ticket A printer is connected on the I/O unit
(ID=0)
Use Up / Down keys to select.
Ticket A Address
Keypad X
ENTER: The ticket A printer is connected on the keypad
number X.
Use Up/Down key to select the address.
ENTER
Ticket A Address
None
ENTER: There is no ticket A printer on the system.
Use Up/Down keys to select.
ENTER
E ery display is deli ered with dip switches on the PC
board. See Instruction Manual, Wiring the display.
ENTER
Select Hose
01
ENTER
Select Display
00
ENTER
Hose Number 1 will be isualized on display Number 00.
System enu
Set Encoder Type
LFC 3000 allows the use of single channel and dual
channels pulse transmitters.
By default, all the systems are programmed to be use with
single channel pulse transmitters.
ENTER
Set Encoder type
Quadrature
Quadrature corresponds to dual channel pulse transmitter.
Use Up / Down keys to select.
Set Encoder type
Single Channel
Single channel pulse transmitter.
In a multi I/O system without PC, this parameter must be
programmed and be the same on each I/O.
ENTER
System enu
System Type
System Type
Non- aster
Use Up / Down keys to select.
Non-Master is used without PC.
Master is used with PC.
ENTER
System enu
Set Report Adr.
A Main printer is necessary to print the entire statistic, stock
le el reports and diagnostic.
This printer must be 80 columns; Epson emulated with a
serial port.
The factory default setting is report address on Keypad 0.
ENTER

Page Number - 10
LFC 3000 Users Manual
Series A
Form 403082
System enu
Set Ticket B Adr.
To fulfill all the needs of the garage super isor, LFC 3000
offers also the flexibility to print a copy of the transaction
tickets. All the printers must be connected through the serial
port and be Epson emulated. This printer can be the main
printer. This instruction must be done on EACH keypad. The
factory default setting is ticket B address on keypad 0.
Ticket B Address
I/O Control Unit
ENTER: The ticket B printer is connected on the I/O unit
(ID=0)
Use Up / down keys to select.
Ticket B Address
None
ENTER: There is no ticket B printer on the system.
Use Up / Down keys to select
Ticket B Address
Keypad x
ENTER: The ticket B printer is connected on the keypad
Number x.
Use Up / Down keys to select the address
ENTER
System enu
Set System PIN
The system PIN code can be modified. Only numerical PIN
is accepted by the system. If the system PIN Number has
been forgotten, it will be necessary to reset the system and
re-configure. See Instruction Manual, under Troubleshoot-
ing, Lost Super isor PIN.
ENTER
System Cfg PIN
****
LFC 3000 operates all the hose reels simultaneously or one
hose reel at a time. When the system is configured in
simultaneous mode, you will be able to dispense on all the
different hoses at the same time.
The factory default setting is simultaneous.
System enu
Set Simultaneous ode
ENTER
Set Simultaneous ode
Non-Simultaneous
Use Up / down keys to select.
Set Simultaneous ode
Simultaneous
In a multi I/O system without PC, this parameter must
programmed and must be the same on each I/O
ENTER
System enu
Pulses per Liter
LFC 3000 is designed to register pulses from 1 to 255 per
liter. Refer to the type of pulse transmitter. To change to
pulses per quart see user menu, Set Language, change
to American English.
Pulse per Liter
100
In a multi I/O system without PC, this parameter must
programmed and be the same and on each I/O.
ENTER
System enu
ax. Dispense
ENTER
Select Hose
0
ax. Dispense
_ 100
ENTER the maximum quantity that will be allowed to be
dispensing on the selected hose.
Then press ENTER and do the same for the other hoses.
System enu
Decimal Place
Decimal Place
1
You can choose the place of the decimal. You only ha e 1 or
2 (use the Up / down arrow key).
( You also ha e to change physically the jumper located in
the display). ENTER

Page Number - 11
Form 403082
LFC 3000 Users Manual
Series A
System enu
Hose Calibration
This prompt is offering the possibility to correct the delay of
the solenoid al e shut-off.
When an operator presets a quantity of fluid to be dis-
pensed, the system will automatically close the solenoid
al e when the preset quantity has been reached. The LFC
3000 counts the pulses coming from the pulse transmitter.
Assuming that the pulse transmitter type is 100 pulses per
liter, the calibration procedure will be as follows;
Preset quantity: 4 liters = 400 pulses
Quantity dispensed: 4.1 lit. = 410 pulses
Difference: 0.1 lit. = 10 pulses
10 will be the calibration factor to enter in the system.
ENTER
Select Hose
01
ENTER
Pulse count
10
ENTER
System enu
Change I/O ID
By default all the I/O units ha e the same address (ID)
Number 0 corresponding to solenoid dri ers (hose reels) 1
to 8. For the installation with multi I/O units (more than 8
hosereels), each I/O must ha e its own address to be
identified by the network.
Power up each I/O successi ely and change their address.
For example ID Number 1 for solenoid dri ers (hose reels)
9 to 16.
ENTER
Changer ID I/O
From 0 to 1
ENTER
The network communicates now with this I/O unit 1 for
hoses 9 to 16.
System enu
Exit
ENTER
Return to Customer Configure Menu at the exit prompt. To
return to the User screen, press twice ENTER.
TRANSACTION CODES
Explanations for the transaction end codes
printed on each transaction ticket:
0 Means that the transaction has been stopped after
the inacti e Timeout:
- its normal in free dispense mode
- The preset quantity has not been totally dispensed
1 In preselect mode, the preset quantity has been
totally dispensed: Completed
2 Input Error in the pulses sequence: for quadrature
pulsers only
3 Count Error: missing pulse in quadrature pulsers
only
4 It means that the power has been shut down during
the transaction: Power down
5 The transaction has been stopped by the emergency
procedure (): System inacti e
6 IOP Error: Microprocessor Error
7 Unauthorized transaction: for appro ed systems only,
quantity dispensed between 0.5Lt and 100Lt.

Page Number - 12
LFC 3000 Users Manual
Series A
Form 403082
FLOW CHART
Enter PIN Number
_ _ _ _
Good Morning
User’s Name
Enter Job Number
_ _ _ _
Good Morning
Supervisor
9999 Enter
Supervisor Menu
Start/Stop
(Enter Reg Number)
_ _ _ _
(Enter Od Number)
_ _ _ _
Enter Hose
_ _ _ 0
Product
Product’s Name
(Enter Qty)
6.7
Dispense Oil
Supervisor Menu
Transact. Rep.
Supervisor Menu
Delivery Rep.
Supervisor Menu
Stock Lev. Rep.
Supervisor Menu
New Stock Level
Supervisor Menu
Set date/time
Supervisor Menu
Set Super PIN
Supervisor Menu
Clear Transacts.
Supervisor Menu
Add new user
Supervisor Menu
Remove user
Supervisor Menu
Cust. Config.
Supervisor Menu
Exit
Customer Menu
_ _ _ _
Customer Menu
Products
Customer Menu
Hose
Customer Menu
Warn. Level
Customer Menu
Stop Level
Cust. Menu
Dispense Mode
Customer Menu
Odom. & Reg.
Customer Menu
Inact. Timeout
Customer Menu
Exit
Customer Menu
Config. Syst.
Customer Menu
Diagnostic
Customer Menu
Init. Timeout
Customer Menu
Set Cust. PIN
Customer Menu
Set Language
Enter
Enter
System Menu
_ _ _ _
System Menu
Test Mode
PIN user - Enter 1111 - Enter 2222 - Ente
r
System Menu
Display Alloc.
System Menu
Exit
System Menu
Change I/O ID
System Menu
Hose Calibration
System Menu
Decimal Place
System Menu
Max Dispense
System Menu
Pulses Per Quart
Syststem Menu
Set Simul. Mode
System Menu
Set Syst. PIN
System Menu
Set Ticket B Address
System Menu
Set Ticket A. Address
System Menu
Set Rep. Addr.
System Menu
System Type
System Menu
Set Encoder Type
Enter
Supervisor Menu
Prod. Delivery
Customer Menu
Stock Mode
Americas:
One Lincoln Way
St. Louis, MO 63120-1578
USA
Phone +1.314.679.4200
Fax +1.800.424.5359
Europe/Africa:
Heinrich-Hertz-Str 2-8
D-69183 Walldorf
Germany
Phone +49.6227.33.0
Fax +49.6227.33.259
Asia/Pacific:
25 Intl Business Park
#01-65 German Centre
Singapore 609916
Phone +65.562.7960
Fax +65.562.9967
© Copyright 2002
Printed in USA
Web site:
www.lincolnindustrial.com