LK-UP211 UPS Control Panel (1.5A)
07 08
—Can be used as a master controller, a slave controller or play a dual role of master & slave
controller at the same me
—As a master controller, connects to the motors or slave controllers to drive them
—As a slave controller, receive the instrucons to drive motors, or drive the motors
independently
—Play a dual role of master & slave controller, not only controlled by higher-level controller,
but also drive motors or lower-level controllers independently
—No maer master, slave or both, it can process all the external signals such as manual
switch, remote and sensors
—Cascade use of the controller, if the master controller connected to an external sensor
(such as smoke sensor, wind and rain sensor, etc.), the slave controller MUST NOT use
inching mode
¢Cascaded control
¢Stroke memory
—The controller can set and memorize opening stroke. Upon the stroke set, the window
opening signal is triggered once, the motor will run the memorized stroke one me
—The default memorized stroke runs for 5 minutes
—Press both of UP/DOWN buons on the controller for 3 seconds, LEDs flash 3 mes and
off, successfully entered the stroke memory seng state
—In the stroke memory seng state, the manual keys are forced to the connued-run
mode, the remote control keys are forced to the inching mode
—Determine the stroke that needs to be memorized by pressing the manual key or the
remote control key by moving or jogging
—Press both of UP/DOWN on the controller for 3 seconds, LEDs flash 5 mes and off, the
memorized stroke set successfully and exit the stroke memory seng state, manual
buons and remote control buons restored to the original mode
—No operaon is performed within 15 seconds, LEDs flash 3 mes and off, the stroke
memory seng state is automacally exited, and the last memorized stroke is retained
—Stroke memory can be set repeatedly. The controller only retains the last successful
stroke value and automacally clears the previous one
—In stroke memory seng state, press both of STOP /DOWN buons on the controller for
3 seconds LEDs flash 3 mes the memorized stroke is deleted and restored to the default
output for 5 minutes
—When the memorized strokes of master controller and slave controller are not the same,
the master controller will run its own memorized stroke. The slave controller will run the
shorter stroke when it receives the cascade signal from the master controller
—The memorized stroke is retained in case the controller is powered down or reset
—When closing the window, the output me is 5 minutes
¢Troubleshoong
—Please read the following instrucons carefully before installing this product
—The control system must be installed by the professional
—The main power must be cut off before wiring to ensure safe operaon
—Two 12V 1.3Ah baeries connected in series
—Please confirm posive and negave polaries before turning on the baeries to ensure
that it cannot be reversed
—The controller does not contain baeries, please purchase with correct size and
specificaons
—Control panel cannot be installed outdoors
—Maximum output power MUST NOT exceed the total rated power of the controller
—Do not use metal objects to touch or cover the controller, otherwise it will affect the
remote control signal recepon
—The maximum transmission distance of the wireless signal can reach 50 meters or more
in the open condion
—The distance between the controller and ground should be more than 1.5 meters
—The distance between the controller and ceiling should be more than 0.3 meters
—The distance between the controller and motor should be more than 1.5 meters
—Avoid stac interference and prevent stac damage to electronic components
—Please use the so wire and cable, aer installaon ensure that the cable carrier is not
affected by the longitudinal tension
—An external sensor must use a product that is compable with this controller
—Non-professionals is not allowed to disassemble the controller. If any funcon is unusual,
please contact your local dealer
.
¢Installaon instrucon
LED flashes, receiver shut down
1. Check the connecon of wires
2. Check the receiver seng
LED on the transmier is off or weak
1. Make sure the right installaon of the baery
2. Change the baery
The transmier and the receiver work well,
the motor does not work
1. Check the wiring of motor
2. Make sure the motor no failure
.