LinkAYL LK-CP711-30A User manual


LK‐CP711‐30AEXTERNAL30APOWERCONTROLPANEL












Feature
Consistsofamotherboardandamembraneswitch
Reset,Open/Stop/ClosebuttonsandLEDindicators
Singlechannelcontrol
CanbecascadedwithLK‐CP6/7/8andLK‐FP3controlpanelthatachieveswindows
ofzonecontrolandgroupcontrol
CompatiblewithallLinkaylremote
CanhandleexternalinputsignalofManualSwitch,RemoteControl,
Smoke/Gas/Rain/Temperature&HumiditySensors
Inchingmodeandcontinued‐runmodesettable
Withstrokememoryfunction
ExternalpowersupplyuptoDC24V/30A


ModelList
ModelInputVolt
(V)
OutputVolt
(V)
Freq
(MHz)Temp(℃)Size(mm)
LK‐CP711‐30A DC24DC24DC12 433.92‐20~+65 160L*110W*40H

Application
ModelExternal
PowerLK‐SCE‐DLK‐LCD LK‐TC LK‐LLK‐L‐SLK‐L38A
600N/1KN
LK‐L38A
1500N
LK‐CP711‐30A720W2515715151510

PanelDescription






LED/KEYColorStatusFunction
L1/K1BlueOn/OffACpowerindicator,Reset
L2/K2GreenOn/Off/FlashOpen
L3/K3RedOn/Off/FlashStop
L4/K4YellowOn/Off/FlashClose

Terminals

SymbolDescriptionSymbolDescription
V+DC24V+FSOFirefeedbackCOM
V‐ DC24V‐ FOOFirefeedbackNO
M+MotorDC24V+FOCFirefeedbackNC
M‐ MotorDC24V‐ 24VOutputDC24V+
MUManualswitchupFSIFiresignalinput
MSManualswitchstopCOMCOMsignal
MDManualswitchdownS+Slavecontrolup
MGManualswitchGNDS‐ Slavecontroldown
TTsensorsignal 12VOutputDC12V+
HHsensorsignalWRDRainsensordown


ControlMode
Controlerhasinchingmodeandcontinued‐runmodewhichisdefault
Inthecontinued‐runmode,presstheup/downkeylessthan1.5seconds,the
motorwillruncontinuously,presstheup/downkeymorethan1.5seconds,the
motorwillstopafterrunningaveryshortmoment
Intheinchingmode,presstheup/downkeylessthan1.5seconds,themotor
willstopafterrunningaveryshortmoment,presstheup/downkeymorethan
1.5seconds,themotorwillruncontinuously
Onlythemanualbuttonsonthepanel,manualswitch,remotecontroland
cascadesignalhaveinchingmode
KeeppressingbothofUPandSTOPbuttononthecontrolerfor5seconds,LEDs
flash3timesandturnoffit’sinchingmodeforthecontroler,repeattheoperation
thecontrolerturnstocontinued‐runmode

Manualcontrol
AfterpoweronalltheLEDslightfor1secondandturnoff,thepowerindicator
LEDnormallyon
Pressresetbutton,alltheLEDslightfor1secondandturnoff,resetsuccessfully
L2willbeexplosion‐flashingaftercontrolerreceivesfiresignal
Externalmanualswitchisequivalenttocontrolerpanelswitch
Themaximumrunningtimeofthemotoris5minutes
Themotorup/downswitchingtimeis500ms
PressUPbutton,thewindowsopen,LEDturnson,turnsoffafter5seconds
PressDOWNbutton,thewindowsclose,LEDturnson,turnsoffafter5seconds
PressSTOPbutton,,themotorsstop,LEDturnson,LEDturnsoffafter1second

Remotecontrol
Thecontrolerencodesby433MHzlearningcode,canstore10setsofcodes
MatchingCode
Powercontroleron,pressSTOPbuttononthecontrolerfor5seconds,LED
flashes3timesandturnsoff
Press[UP]within15seconds
LEDflashes3timesandturnsoff,codematchedsuccessfully
ClearingSingleCode
Powercontroleron
PressSTOPkeyonthecontrolerfor5S,LEDflashes3timesandturnsoff
PressDOWNbuttonontheremotewithin15seconds
LEDflashes3timesandturnsoff,codeclearedsuccessfully
ClearingAllCodes
Powercontroleron,pressSTOP&DOWNbuttononthecontrolerfor5seconds
LEDsflash3timesandturnoff,allthecodeswillbedeletedafterthisoperation

SignalControl
Manualsignal.Controlthewindowbythebuttonsonitself,externaldrycontact
manualswitchandRFremote
Firesignal.Capableofreceivingasignalfromfirecenter,smokesensor,gas
detectoropenthewindowautomatically
Rainsignal.Afterreceivingthesignalofrainsensorclosethewindow
Temperature/humiditysignal.Controlthewindowbyprocessingexternal
temperature/humiditysensor

SignalandPriority
SignalManualSignalFireSignalRainSignalT/HSignal
Priority1234
Manualsignalincludesthesignalfrombuttonsonthecontroler,externaldry
contactmanualswitch,walltransmitter,handheldremote,wirelessW/Rsensor,
wirelesstimerandcascadedsignal
Firesignalincludesthesignalfromfirecentre,smokesensorandgasdetector
Rainsignalincludesthesignalfromwiredwindandrainsensor,NOTincluding
wirelessrainsensor
T/Hsignalincludesthesignalfromtemperatureorhumiditysensor
ResetandShielding
Aftermanualsignalprocessedcontrolerresets&receivesinputsignalinrealtime
Afterprocessingthesignalfromfirecentre,smokesensororgasdetector,the
controlerimmediatelyshieldsalltheinputsignals,thecontrolermustberesetby
pressingK1manually.
Afterwiredrainsensorsignalprocessed,thecontrolershieldslowerpriority
signal,onlyreceivesthehigherprioritysignaluntilresetormanualsignal
processed
AfterT&Hsensorsignalprocessed,thecontrolerisintheresetstate
Ifthecontrolerisnotconnectedtoatemperatureandhumiditysensor,theT/H
portmustbeshielded(putoptionswitch“Y”position),otherwiseitwillaffect
thecontrolofotherinputsignal

CascadedControl
LK‐CP711‐30Acanbeusedasamastercontroler,aslavecontrolerorplayadual
roleofmaster&slavecontroleratthesametime.
Asamastercontroler,connectstothemotorsorslavecontrolerstodrivethem
Asaslavecontroler,inputterminalsS+andS‐ areconnectedtotheoutput
terminalsM+andM‐ofthemastercontrolertoreceivetheinstructionstodrive
motors,ordrivethemotorsindependently
Playadualroleofmaster&slavecontroler,notonlycontrolledbyhigher‐level
controler,butalsodrivemotorsorlower‐levelcontrolersindependently
Nomattermaster,slaveorboth,itcanprocessalltheexternalsignalssuchas
manualswitch,remoteandsensors

StrokeMemory
Thecontrolercansetandmemorizetheopeningstroke.Uponthestrokeset,the
windowopeningsignalistriggeredonce,themotorwillrunthememorized
strokeonetime
Thedefaultmemorizedstrokerunsfor5minutes
Presstheupanddownkeysonthecontrolerfor3seconds,LEDsflash3times
andoff,successfullyenteredthestrokememorysettingstate
Inthestrokememorysettingstate,themanualkeysareforcedtothe
continued‐runmode,theremotecontrolkeysareforcedtotheinchingmode
Determinethestrokethatneedstobememorizedbypressingthemanualkeyor
theremotecontrolkey
Afterthememorizedstrokesdetermined,presstheupanddownkeysonthe
controlerfor3seconds,LEDsflash5timesandoff,thememorizedstrokeset
successfullyandexitthestrokememorysettingstate,manualbuttonsand
remotecontrolbuttonsrestoredtotheoriginalmode
Instrokememorysettingstate,nooperationisperformedwithin15seconds,
LEDsflash3timesslowlyandoff,thestrokememorysettingstateisautomatically
exited,andthelastmemorizedstrokeisretained
Strokememorycanbesetrepeatedly.Thecontroleronlyretainsthelast
successfulstrokevalueandautomaticallyclearsthepreviousone
Instrokememorysettingstate,pressupanddownbuttonsonthecontrolerfor3
secondsLEDsflash3timesthememorizedstrokeisdeletedandrestoredtothe
defaultoutputfor5minutes
Whenthememorizedstrokesofmastercontrolerandslavecontrolerarenotthe
same,themastercontrolerwillrunitsownmemorizedstroke.Theslave
controlerwillruntheshorterstrokewhenitreceivesthecascadesignalfromthe
mastercontroler
Thememorizedstrokeisretainedincasethecontrolerispowereddownorreset
Whenclosingthewindow,theoutputtimeis5minutes

Installationinstruction
Pleasereadthefollowinginstallationinstructionscarefullybeforeinstalling
Theinstallationmustcomplywiththeeffectivelocalelectricityspecifications
Thecontrolsystemmustbeinstalledbytheprofessional
Themaximumoutputpowerofcontrolercannotexceedtheratedtotalpower
Themainpowermustbecutoffbeforewiringtoensuresafeoperation
Donotusemetalobjectstotouchorcoverthecontroler,otherwiseitwillaffect
theremotecontrolsignalreception
Themaximumtransmissiondistanceofthewirelesssignalcanreach50metersor
moreintheopencondition
Thedistancebetweencontrolerandgroundshouldbegreaterthan1.5meters
Thedistancebetweencontrolerandceilingshouldbegreaterthan0.3meters
Thedistancebetweencontrolerandmotorshouldbegreaterthan1.5meters
Avoidstaticinterferenceandpreventstaticdamagetoelectroniccomponents
Pleaseusethesoftwireandcable,afterinstallationensurethatthecablecarrier
isnotaffectedbythelongitudinaltension
Anexternalsensormustuseaproductthatiscompatiblewiththiscontroler
Cascadeuseofthecontroler,ifthemastercontrolerconnectedtoan
externalsensor(suchassmokesensor,windandrainsensor,etc.),
theslavecontrolerMUSTNOTuseinchingmode,incasethemaster
controlerreceivedthesmokesignaltoopenthewindow,theslave
controlerwillopenthewindowfor160msandstop
Ifthecontrolerisnotconnectedtoatemperatureandhumiditysensor,theT/H
portmustbeshielded(putoptionswitchoption3to“Y”position),otherwiseit
willaffectthecontrolofotherinputsignal
Non‐professionalsisnotallowedtodisassemblethecontroler.Ifanyfunctionis
abnormal,pleasecontactyourlocaldealer

Troubleshooting
No. SymptomSolution
1LEDflashes,receivershutdown1.Checktheconnectionofwires
2.Checkthereceiversetting
2LEDonthetransmitterisofforweak
1.Makesuretherightinstallationof
thebattery.
2.Changethebattery
3Thetransmitterandthereceiver
workwell,themotordoesnotwork
1.Checkthewiringofmotor
2.Makesurethemotornofailure

Other LinkAYL Control Panel manuals

LinkAYL LK-UP211 User manual

LinkAYL

LinkAYL LK-UP211 User manual

LinkAYL LK-UP24 Series User manual

LinkAYL

LinkAYL LK-UP24 Series User manual

LinkAYL LK-CP611 User manual

LinkAYL

LinkAYL LK-CP611 User manual

LinkAYL LK-CP64 Series User manual

LinkAYL

LinkAYL LK-CP64 Series User manual

LinkAYL LK-CP63X Series User manual

LinkAYL

LinkAYL LK-CP63X Series User manual

LinkAYL LK-FP3 User manual

LinkAYL

LinkAYL LK-FP3 User manual

LinkAYL LK-UP22 Series User manual

LinkAYL

LinkAYL LK-UP22 Series User manual

LinkAYL LK-CP62 Series User manual

LinkAYL

LinkAYL LK-CP62 Series User manual

LinkAYL LK-CP63 Series User manual

LinkAYL

LinkAYL LK-CP63 Series User manual

Popular Control Panel manuals by other brands

BFT NETTUNO B Installation and user manual

BFT

BFT NETTUNO B Installation and user manual

Balboa Instruments ML551 user guide

Balboa Instruments

Balboa Instruments ML551 user guide

X10 MC10A owner's manual

X10

X10 MC10A owner's manual

Bosch DS6R2 Installation and operation guide

Bosch

Bosch DS6R2 Installation and operation guide

DITEC E1T installation manual

DITEC

DITEC E1T installation manual

Advanced LIFELINE Px-100 product manual

Advanced

Advanced LIFELINE Px-100 product manual

EMKO PROOP 7 Series quick start guide

EMKO

EMKO PROOP 7 Series quick start guide

Frontpoint Control Panel Get to know

Frontpoint

Frontpoint Control Panel Get to know

Kentec Electronics Sigma XT K11031F2 Operation and maintenance manual

Kentec Electronics

Kentec Electronics Sigma XT K11031F2 Operation and maintenance manual

EWM Synergic operating instructions

EWM

EWM Synergic operating instructions

Controls C4F-F10198 product manual

Controls

Controls C4F-F10198 product manual

Heatcraft Refrigeration Products Beacon II H-IM-79G Installation and operation manual

Heatcraft Refrigeration Products

Heatcraft Refrigeration Products Beacon II H-IM-79G Installation and operation manual

AMX AutoPatch CP-20A instruction manual

AMX

AMX AutoPatch CP-20A instruction manual

eKey home series operating instructions

eKey

eKey home series operating instructions

Contour ShuttleXpress user guide

Contour

Contour ShuttleXpress user guide

SpaNet XS-2000 Quick reference guide

SpaNet

SpaNet XS-2000 Quick reference guide

Chamberlain Merlin C98 Owner's instructions

Chamberlain

Chamberlain Merlin C98 Owner's instructions

Satel CA-6 KLED-S Quick user guide

Satel

Satel CA-6 KLED-S Quick user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.