LinkAYL LK-CP62 Series User manual

LK‐CP62XSERIESCONTROLPANEL
LK‐CP621LK‐CP622LK‐CP625
Feature
Controllerisusedinwindowopener,curtainmotoranddooropener24VDCmotor
control
Powerindicator/reset,Open/Stop/Close&channelselectionbuttonswithbacklight
SingleChannel,dualChannel,5Channelandcascadecontrols
CascadecontrolcanbecascadedwithLK‐UP2,LK‐FP3,LK‐CP6/CP7/CP8that
achieveswindowsofzonecontrolandgroupcontrol
CanhandleexternalinputsignalofManualSwitch,RemoteControl,Timer
Smoke/Gas/Rain/Temperature&HumiditySensors
Outputfirefeedbacksignaltofirecentre
CompatiblewithallLinkaylremote
Inchingmodeandcontinued‐runmodesettable
Withstrokememoryfunction
Built‐inswitchingpowersupply30A/40A
ModelList
ModelPower
(W)
Control
Method
InputVolt
(V)
Output
Volt(V)
Temp
(℃)
Size
(mm)
LK‐CP621‐30A 720
1waysingle
AC110/AC230 DC24
DC12
‐20
~
+65
292(L)
258(W)
87(H)
LK‐CP621‐40A 960
LK‐CP622‐30A 7202way
single/group
LK‐CP622‐40A 960
LK‐CP625‐30A 7205way
single/group
LK‐CP625‐40A 960
Application
ModelLK‐SCE‐DLK‐LCD LK‐TC LK‐LLK‐L‐SLK‐L38A
600N/1000N
LK‐L38A
1500N
LK‐CP621‐30A 2515715151510
LK‐CP621‐40A 33201020202013
LK‐CP622‐30A 2515715151510
LK‐CP622‐40A 33201020202013
LK‐CP625‐30A 2515715151510
LK‐CP625‐40A 33201020202013

Key&LED
Led/KeyColorStatusFunction
L1/K1BlueOn/OffACpowerindicator,Reset
L2/K2GreenOn/Off/Flash Open
L3/K3Red Stop
L4/K4Yellow Close
L5/K5Blue Channel1
L6/K6Blue Channel2
L7/K7Blue Channel3
L8/K8Blue Channel4
L9/K9Blue Channel5
Terminals
SymbolDescriptionSymbolDescription
LACLivewireFSOFirefeedbackCOM
NACNullwireFOOFirefeedbackNO
EACEarthwireFOCFirefeedbackNC
24V+DC24VInput+24VOutputDC24V+
24V‐ DC24VInput‐ FSIFiresignalinput
M+MotorDC24V+COMCOMsignal
M‐ MotorDC24V‐ S+Slavecontrolup
MUManualswitchup S‐ Slavecontroldown
MSManualswitch12VOutputDC12V+
MDManualswitchWRDRainsensordown
MGManualswitchT/HT/Hsensorsignal

ControlMode
Controlerhasinchingmodeandcontinued‐runmodewhichisdefault
Inthecontinued‐runmode,presstheup/downkeylessthan1.5seconds,the
motorwillruncontinuously,presstheup/downkeymorethan1.5seconds,the
motorwillstopafterrunningaveryshortmoment
Intheinchingmode,presstheup/downkeylessthan1.5seconds,themotorwill
stopafterrunningaveryshortmoment,presstheup/downkeymorethan1.5
seconds,themotorwillruncontinuously
Onlythemanualbuttonsonthepanel,manualswitch,remotecontrolandcascade
signalhaveinchingmode
KeeppressingbothofUPandSTOPbuttononthecontrolerfor5seconds,LEDs
flash3timesandturnoffit’sinchingmodeforthecontroler,repeattheoperation
thecontrolerturnstocontinued‐runmode
Manualcontrol
AfterpoweronalltheLEDslightfor1secondandturnoff,thepowerindicatorLED
normallyon
Pressresetbutton,alltheLEDslightfor1secondandturnoff,resetsuccessfully
L2willbeexplosion‐flashingaftercontrolerreceivesfiresignal
Externalmanualswitchisequivalenttocontrolerpanelswitch
Themaximumrunningtimeofthemotoris5minutes
Themotorup/downswitchingtimeis500ms
GroupControl
Bydefault,L1isnormallyon,therestLEDsareoffasgroupcontrolstatus
PressUPbutton,thewindowsopen,LEDturnson,turnsoffafter5seconds
PressDOWNbutton,thewindowsclose,LEDturnson,turnsoffafter5seconds
PressSTOPbutton,,themotorsstop,LEDturnson,LEDturnsoffafter1second
SingleChannelControl
PresschannelselectionkeysthecorrespondingLEDlights,channelselected
Pressthechannelselectionbuttonagainornooperationoncontrolerthin10
seconds,LEDturnsoff,channelunselected
Intheprocessofopening/closingthecurrentwindow,youcanselectanother
channel(s)todrivethewindow
Remotecontrol
Thecontrolerencodesby433MHzlearningcode,canstore10setsoftransmission
codes
Thecontrolerdefaultstomultiplechannel,singlechannelcontrolerhasthesame
wayasmultiplechannelone
MatchingCode
Powerthecontroleron,choosethechannel(s)youwanttoset,canbesettoany
combinationofchannel1‐5
PressingSTOPbuttononcontrolerfor5seconds,LEDflashes3timesandturnsoff
Choosethechannelyouwanttosetontheremote,press[UP]within15seconds
LEDflashes3timesandturnsoff,codematchedsuccessfully
ClearingSingleCode
Powerthecontroleron
KeeppressingSTOPkeyonthecontrolerfor5S,LEDflashes3timesandturnsoff
PressDOWNbuttonontheremotewithin15seconds
LEDflashes3timesandturnsoff,codeclearedsuccessfully
ClearingAllCodes
Powercontroleron,pressingSTOP&DOWNbuttononthecontrolerfor5seconds
LEDsflash3timesandturnoff,allthecodeswillbedeletedafterthisoperation

SignalControl
Manualsignal.Controlthewindowbythebuttonsonitself,externaldrycontact
manualswitchandRFremote
Cascadedsignal.Asamastercontrolersendssignaltotheslavecontroler,canalso
beusedasslavecontrolertoreceivethesignalfromthemastercontrolertodrive
thewindow
Firesignal.Capableofreceivingasignalfromfirecenter,smokesensor,gas
detectoropenthewindowautomatically,sendfeedbacksignaltofirecentre
Rainsignal.Afterreceivingthesignalofrainsensorclosethewindow
Temperature/humiditysignal.Controlthewindowbyprocessingexternal
temperature/humiditysensor
SignalandPriority
Priority1234
SignalManualSignalFireSignalW/RSignalT/HSignal
Device
Panelbuttons
Manualswitch
Remote
Mastercontroler
Smokesensor
Gasdetector
Wired
rainsensor
temperaturesensor
humiditysensor
ResetandShielding
Aftermanualsignalprocessedcontrolerresets&receivesinputsignalinrealtime
Afterprocessingthesignalfromfirecentre,smokesensororgasdetector,the
controlerimmediatelyshieldsalltheinputsignals,thecontrolermustberesetby
pressingK1manually.
Afterwiredrainsensorsignalprocessed,thecontrolershieldslowerprioritysignal,
onlyreceivesthehigherprioritysignaluntilresetormanualsignalprocessed
AfterT&Hsensorsignalprocessed,thecontrolerisintheresetstate
Ifthecontrolerisnotconnectedtoatemperatureandhumiditysensor,theT/H
portmustbeshielded(putoptionswitchoption3to“Y”position),otherwiseit
willaffectthecontrolofotherinputsignal
CascadedControl
Canbeusedasamastercontroler,aslavecontrolerorplayadualroleofmaster&
slavecontroleratthesametime.
Asamastercontroler,connectstothemotorsorslavecontrolerstodrivethem
Asaslavecontroler,inputterminalsS+andS‐ areconnectedtotheoutput
terminalsM+andM‐ ofthemastercontrolertoreceivetheinstructionstodrive
motors,ordrivethemotorsindependently
Playadualroleofmaster&slavecontroler,notonlycontrolledbyhigher‐level
controler,butalsodrivemotorsorlower‐levelcontrolersindependently
Nomattermaster,slaveorboth,itcanprocessalltheexternalsignalssuchas
manualswitch,remoteandsensors
Cascadeuseofthecontroler,ifthemastercontrolerconnectedtoan
externalsensor(suchassmokesensor,windandrainsensor,etc.),the
slavecontrolerMUSTNOTuseinchingmode,incasethemaster
controlerreceivedthesmokesignaltoopenthewindow,theslave
controlerwillopenthewindowforaveryshortmomentandstop
StrokeMemory
Thecontrolercansetandmemorizetheopeningstroke.Uponthestrokeset,the
windowopeningsignalistriggeredonce,themotorwillrunthememorizedstroke
onetime
Thedefaultmemorizedstrokerunsfor5minutes
Presstheupanddownkeysonthecontrolerfor3seconds,LEDsflash3timesand
off,successfullyenteredthestrokememorysettingstate
Inthestrokememorysettingstate,themanualkeysareforcedtothe
continued‐runmode,theremotecontrolkeysareforcedtotheinchingmode
Selectthechannel(S)tobeset,thedefaultisallselected,allthechannelindicators
light.Pressthechannelselectionkey(S),theindicatorslight,pressthechannel
selectionkey(S)againtheindicatorisoff,itisdeselected.Thesettingisinvalid
withoutoperationin15seconds

Afterthechannelselected,determinethestrokethatneedstobememorizedby
pressingthemanualkeyortheremotecontrolkeybymovingorjogging
Thememorizedstrokecanbesettoonechanneloranycombinationofchannel
Afterthememorizedstrokesdetermined,turnonallthechannelindicatorsfor
settingthememorizedstroke.Presstheupanddownkeysonthecontrolerfor3
seconds,LEDsflash5timesandoff,thememorizedstrokesofallchannelsset
successfullyandexitthestrokememorysettingstate,manualbuttonsandremote
controlbuttonsrestoredtotheoriginalmode
Instrokememorysettingstate,nooperationisperformedwithin15seconds,LEDs
flash3timesslowlyandoff,thestrokememorysettingstateisautomaticallyexited,
andthelastmemorizedstrokeisretained
Strokememorycanbesetrepeatedly.Thecontroleronlyretainsthelastsuccessful
strokevalueandautomaticallyclearsthepreviousone
Instrokememorysettingstate,pressupanddownbuttonsonthecontrolerfor3
secondsLEDsflash3timesthememorizedstrokeisdeletedandrestoredtothe
defaultoutputfor5minutes
Whenthememorizedstrokesofmastercontrolerandslavecontrolerarenotthe
same,themastercontrolerwillrunitsownmemorizedstroke.Theslavecontroler
willruntheshorterstrokewhenitreceivesthecascadesignalfromthemaster
controler
Thememorizedstrokesetforeachchannelisretainedincasethecontroleris
powereddownorreset
Whenclosingthewindow,theoutputtimeis5minutes
Installationinstruction
Pleasereadthefollowinginstructionscarefullybeforeinstallingthisproduct
Installingthisproductmustcomplywiththeeffectivelocalelectricityspecifications
Thecontrolsystemmustbeinstalledbytheprofessional
Themainpowermustbecutoffbeforewiringtoensuresafeoperation
Additivemaximumoutputpowerofeachsinglechannelofdoublechannel
controllerMUSTNOTexceedthetotalratedpowerofthecontroller
Additivemaximumoutputpowerofeachsinglechannelof5channelcontroller
MUSTNOTexceedthetotalratedpowerofthecontroller,andthemaximum
outputcurrentofeachchannelMUSTNOTexceed10A
Donotusemetalobjectstotouchorcoverthecontroler,otherwiseitwillaffectthe
remotecontrolsignalreception
Themaximumtransmissiondistanceofthewirelesssignalcanreach50metersor
moreintheopencondition
Thedistancebetweenthecontrolerandgroundshouldbemorethan1.5meters
Thedistancebetweenthecontrolerandceilingshouldbemorethan0.3meters
Thedistancebetweenthecontrolerandmotorshouldbemorethan1.5meters
Avoidstaticinterferenceandpreventstaticdamagetoelectroniccomponents
Pleaseusethesoftwireandcable,afterinstallationensurethatthecablecarrieris
notaffectedbythelongitudinaltension
Anexternalsensormustuseaproductthatiscompatiblewiththiscontroler
Non‐professionalsisnotallowedtodisassemblethecontroler.Ifanyfunctionis
abnormal,pleasecontactyourlocaldealer
This manual suits for next models
9
Table of contents
Other LinkAYL Control Panel manuals

LinkAYL
LinkAYL LK-UP24 Series User manual

LinkAYL
LinkAYL LK-FP3 User manual

LinkAYL
LinkAYL LK-CP64 Series User manual

LinkAYL
LinkAYL LK-CP711-30A User manual

LinkAYL
LinkAYL LK-UP211 User manual

LinkAYL
LinkAYL LK-UP22 Series User manual

LinkAYL
LinkAYL LK-CP63 Series User manual

LinkAYL
LinkAYL LK-CP611 User manual

LinkAYL
LinkAYL LK-CP63X Series User manual