Lite-Puter DX-1210 User manual

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 1
User Manual
DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230
DX-630/DX-640
12/6 Channel Modular Dimmer Pack
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 2
INDEX
1 THE REGULATION OF SAFE USAGE: ..................................................................................................3
2 INTRODUCTIONS.............................................................................................................................4
2-1 FEATURES...........................................................................................................................................4
2-2 SPECIFICATIONS ...................................................................................................................................5
2-3 STRUCTURE ........................................................................................................................................6
2-4 DIMENSIONS ......................................................................................................................................7
3 INSTALLATION AND FUNCTION INTRODUCTION ..............................................................................8
3-1 INSTALLATION......................................................................................................................................8
3-2 P-10/P-10T/P-27/P-27AF/P-30/P-30A/P-40A .................................................................................9
3-3 DP-5 ..............................................................................................................................................10
3-4 CONNECTION OF DMX &ANALOG .....................................................................................................11
3-4-1 ANALOG CONNECTOR......................................................................................................................11
3-4-2 DMX-512 CONNECTOR ..................................................................................................................11
3-5 REAR PANEL .....................................................................................................................................12
4 OPERATIONS .................................................................................................................................13
4-1 MODES ...........................................................................................................................................13
4-2 DMX ADDRESS SETTING.....................................................................................................................14
4-3 HOW TO CONNECT OVER 2SETS OF DX-1220/DX-1220AF SERIES...........................................................14
4-4 LOCK/UNLOCK ..................................................................................................................................15
4-5 FUN (FUNCTION)...........................................................................................................................15
4-6 SET FUNCTIONS................................................................................................................................17
4-7 SPECIFICATIONS OF PLUG (OPTIONAL)....................................................................................................23
4-8 WIRING DIAGRAM OF DX-1210/1210T/1220/1220AF/1230/630/640................................................24
LIMITED WARRANTY ........................................................................................................................26
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 3
1 The Regulation of Safe Usage:
(1) Before Connecting to Loads:
Individual channel must be set dimming or switch function before turning on.
The non-dimming lamp may be damaged in dimming function.
(2) Dimming Output:
DX-1210/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 are leading-edge dimmers.
DX-1210T is a trailing-edge dimmer.
Some loads/lamps might not compatible to leading-edge or trailing-edge dimmer. Please
check the manual of the load before connecting.
(3) Maximum Capacity-1:
For testing (about 30 minutes)
DX-1210/DX-1210T: Maximum output of individual channel is 10A;
DX-1220/DX-1220AF: Maximum output of individual channel is 25A;
DX-1230: Maximum output of individual channel is 30A:
For testing (about 10 minutes)
DX-630: Maximum output of individual channel is 30A;
DX-640: Maximum output of individual channel is 40A:
(4) Maximum Capacity-2:
For several hours usage (theater or stage)
DX-1210/DX-1210T: maximum output of individual channel ≦10A ;
DX-1220/DX-1220AF: maximum output of individual channel ≦16A ;
DX-1230: maximum output of individual channel ≦25A ;
DX-630: maximum output of individual channel ≦30A ;
DX-640: maximum output of individual channel ≦35A :
(5) Maximum Capacity-3:
DX-1210/DX-1210T: maximum output of individual channel ≦10A;
DX-1220/DX-1220AF: maximum output of individual channel ≦12A;
DX-1230: maximum output of individual channel ≦18A;
DX-630: maximum output of individual channel ≦20A;
DX-640: maximum output of individual channel ≦30A;
Works for 24/7 (hotels or restaurants)
(6) Environment :
Temperature: under 35°C
Case inside temperature: under 45°C
Humidity: 40% - 80%
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 4
2 Introductions
2-1 Features
1. Removable dimming modules
2. DMX-512 or analog 0-10V DC input.
3. Each channel can be set as dimming or switch mode.
4. C2 and C3 dimming curves
5. Dimming test function for each channel or all channels.
6. Universal AC input (100-240 V).
7. Maximum wattage limit setting.
8. Each output can be set warm-up from 0 to 6.0% to protect lamps.
9. Built-in MCB on each output.
10. Thermal-controlled fan
11. Built-in active anti-flicker circuit, minimizing the shimmering issue on LED lamps (only applicable
to DX-1220AF, DX-1210T)
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 5
2-2 Specifications
(1) Input: AC100-240, 45-63Hz,
3 phase 4 wire or single phase 3 wire
(2) Output:
DX-1210: Leading-edge dimming output, 10A MAX output per channel
DX-1220/DX-1220AF: Leading-edge dimming output, 20A MAX output per channel
DX-1230: Leading-edge dimming output, 30A MAX output per channel
DX-630: Leading-edge dimming output, 30A MAX output per channel
DX-640: Leading-edge dimming output, 40A MAX output per channel
DX-1220AF: Leading-edge dimming output (with built-in anti flicker circuit), 20A Max output
per channel
DX-1210T: Trailing-edge dimming output (with built-in anti flicker circuit), 10A MAX output per
channel
(3) Analog signal input voltage: 0-10V DC
(4) DMX signal (5 pin XLR): DMX-512 / 1990
(5) Dimension: 19” 4U; 482(L) x 176(H) x 260(D)mm
(6) Weight:
DX-1210: 20 kg
DX-1210T: 19kg
DX-1220: 21 kg
DX-1220AF: 21 kg
DX-1230: 23 kg
DX-630: 17 kg
DX-640: 20 kg
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 6
DX-1210/1220/1230/630/640 meets with specifications as follows:
1. EN 55014
2. EN 61000-3-2
3. EN 61000-3-3
4. EN 50140
5. EN 61000-4-2
6. EN 61000-4-4
7. EN 61000-4-5
8. EN 61000-4-11
9. ENV 50141
2-3 Structure
Magnetic Circuit Breaker (M.C.B)
DX-1210: 10A M.C.B on each module (P-10)
DX-1210T: 10A M.C.B on each module (P-10T)
DX-1220/DX-1220AF: 25A M.C.B on each module (P-27/P-27AF)
DX-1230: 30A M.C.B on each module (P-30)
DX-630: 32A M.C.B on each module (P-30A)
DX-640: 40A M.C.B on each module (P-40A)
Thermal-controlled fan
When the internal temperature is over 34℃, the fans start to work 1 minute and stop 1 minute in turn;
over 37℃, the fans turn on continuously; over 63℃, all output will be stopped until the temperature
is under 60℃.
SSR
40A/600V (75℃) Itrms=40A; Itsm=350A / 60HZ , 300A / 50HZ (25℃) According with UL 81734
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 7
2-4 Dimensions
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 8
3 Installation and function introduction
3-1 Installation
DX-1210 is composed of 12 pieces of P-10.
DX-1210T is composed of 12 pieces of P-10T.
DX-1220/DX-1220AF is composed of 12 pieces of P-27/P-27AF.
DX-1230 is composed of 12 pieces of P-30.
DX-630 is composed of 6 pieces of P-30A.
DX-640 is composed of 6 pieces of P-40A.
All models come with a DP-5 (control interface).
Front panel
DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230
DX-630/640
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 9
3-2 P-10/P-10T/P-27/P-27AF/P-30/P-30A/P-40A
P-10/P-10T/P-27/P-27AF/P-30 (Dimming Module)
P-30A/P-40A (Dimming Module)
(1) UNLOCK / LOCK KNOB: PULL-UNLOCK, PUSH-LOCK.
(2) AC OUTPUT INDICATOR.
(3) TRIG INDICATOR.
(4) 25A MAGNETIC CIRCUIT BREAKER.
(5) VENTILATOR
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 10
3-3 DP-5
( 6) PHASE INPUT INDICATORS
( 7) DMX SIGNAL INPUT INDICATOR
( 8) LED DISPLAY
( 9) ◄BUTTON
(10) ▲BUTTON
(11) ►BUTTON
(12) CANCEL BUTTON
(13) SELECT BUTTON
(14) ▼BUTTON
(15) SET / SETTING BUTTON
(16) FUNCTION BUTTON
(17) MODE BUTTON
(18) 5 PIN DMX "OUT" CONNECTOR
(19) 5 PIN DMX "IN" CONNECTOR
(20) ANALOG"IN"CONNECTOR(0-10VDC)
(21) TERMINATE SWITCH
(22) UNLOCK / LOCK KNOB: PULL-UNLOCK / PUSH-LOCK
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 11
3-4 Connection of DMX & ANALOG
3-4-1 Analog Connector
PIN 1 ~ 12: CH-1 ~ CH-12
PIN 13: NC
PIN 14: DC+12V / 100mA
PIN 15: GND
3-4-2 DMX-512 Connector
PIN 1: GND
PIN 2: DATA -
PIN 3: DATA +
PIN 4: NC
PIN 5: NC
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 12
3-5 Rear Panel
(23) AC Main power input terminal (3 phase 4 wire)
(24) Thermal-controlled fans
(25) Load output terminal
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 13
4 Operations
4-1 Modes
DX-1220/DX-1220AF series offer 3 operation modes:
1. DMX mode
2. Analog mode
3. OFF mode
4-1-1 DMX Mode
In DMX mode, DX-1210/1220/1220AF/1230/630/640 will accept DMX-512 signal input or analog 0 -
10VDC signal.
Press "MODE" key to choose DMX mode, the LED will display the selected address of DMX as follows,
and then press "SEL" key to confirm.
-
4-1-2 Analog Mode
In the analog mode, DX-1220/DX-1220AF will only accept analog signal input.
Press "MODE" key to choose Analog mode, the LED will display as follows, and then press "SEL" to
confirm.
.
4-1-3 OFF Mode
In the OFF mode, DX-1210/1210T/1220/1220AF/1230/630/640 will not accept any external signal.
Press "MODE" key to choose OFF mode, the LED will be display as follows,
and then press "SEL" to confirm.
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 14
4-2 DMX Address Setting
Press "MODE" key to choice DMX mode, and then press the assist key to confirm the start address of
DMX channels.
Assist Keys:
Press【►】: Increase channel number
e.g.: Led display from d 0 0 1 to d 0 0 2.
Press【◄】: Decrease channel number
e.g.: Led display from d 0 0 2 to d 0 0 1.
Press【▲】:
DX-1210/1210T/1220/1220AF/1230 increases 12 channel number。
e.g.
:
d 0 0 1 becomes d 0 1 3
DX-630/640 increases 6 channel number。
e.g.
:
d 0 0 1 becomes d 0 07
Press【▼】:Restore back to d 0 0 1.
Press【SEL】: Select/confirm
4-3 How to Connect Over 2 Sets of DX-1220/DX-1220AF Series
Important:
When multiple DMX-512 dimmer connected in daisy chain, the terminate switch on last dimmer
should turn on. The terminate switches on rest dimmer should turn off.
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 15
4-4 Lock/Unlock
LOCK: Press 【FNC】+【MODE】+【▲】
UNLOCK: Press 【FNC】+【MODE】+【▼】
4-5 FUN (FUNCTION)
Press "FNC" key in turn and the LED will display 5 functions as follows:
(1) Display dimming level.
(2) Dimming output test.
(3) Fade in/ fade out test.
(4) Display voltage input.
(5) Display internal temperature.
4-5-1 Display Dimming Level
..
Press【►】: Increase 1 channel.
e.g.: Led display from 0 1.0.0 to 0 2.0.0
Press【◄】: Decrease 1 channel.
e.g.: Led display from 0 2.0.0 to 0 1.0.0
Channel Number
Dimming Level
00 - FL(100%)
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 16
4-5-2 Dimming Output Test
Please turn off DMX signal input and analog signal input before using this function.
.
Press【►】: Test single channel - Increase 1 channel
e.g.: Led displays from 0 1. 0 0 to 0 2. 0 0.
Press【◄】: Test single channel - decrease 1 channel
e.g.: Led displays from 0 2.0 0 to 0 1. 0 0.
Press【▲】:Increase dimming level.
e.g.: Led displays from 0 8.0 0 to 0 8. F L .
Press【▼】: Decrease dimming level.
e.g.: Led displays from 0 8.F L to 0 8. 0 0 .
Press【CAN】: Return
4-5-3 Fade In / Fade Out Test
Please turn off DMX signal input and analog signal input before using this function.
....
Press【►】: Auto fade one channel - Increase channel.
Press【◄】: Auto fade one channel - decrease channel.
Press【SEL】: Confirm
Press【CAN】: Return
Test all channels
Dimming output level
Auto fade in/fade out
All channels
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 17
4-5-4 Display Voltage Input
The function is to display AC voltage input.
..
4-5-5 Display Internal Temperature
..
When the internal temperature is over 34°C , the fans start to work 1 minute and stop 1 minute
in turn.
When the internal temperature is over 37°C , the fans turn on continuously.
When the internal temperature is over 63°C , all output will be stopped until the temperature is
under 60°C . In this case, please check whether the dimmer is overloaded.
4-6 SET Functions
Press "SET" key in turn and the LED will display 5 functions as follows:
1. Dimmer warm-up 0% - 6.0%.
2. Dimming or switch (non-dim) modes
3. Fader time: 0.1 SEC - 30 MIN.
4. Dimming curves.
5. Maximum wattage limit setting
4-6-1 Dimmer Warm-up
...
Press【►】: Increase channel.
Press【◄】:Decrease channel.
Press【▲】:Increase dimmer- warm up value.
Press【▼】: Decrease dimmer- warm up value..
Press【CAN】: Return
Warm-up function of a channel will be invalid if the channel is set to switch mode (non-dim) .
All channels
Warm up level
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 18
4-6-2 Dimming/ Switch Modes
Make sure dimming/switching mode is correctly set before turning on the power.
Never set dim on the channel with a non-dimmable loads..
All channels are in dimming mode.
All channels are in switch mode.
Some channels are dimming; some channels are switch.
Press【►】: Increase channel number
Press【◄】: Decrease channel number
Press【▲】: Switch (non-dim);
Press【▼】: Dimming
Press【SEL】: Select/confirm
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 19
4-6-3 Fader Time (for architectural lighting application)
≡
Press【►】: Increase channel number
Press【◄】: Decrease channel number
Press【▲】: Increase fade time
Press【▼】: Decrease a time
Press【SEL】: Select/confirm
Please check the fade time code in 4-6-4
≡: All channels
1 : 1st channel
2 : 2nd channel
3 : 3rd channel
4 : 4th channel
5 : 5th channel
6 : 6th channel
7 : 7th channel
8 : 8th channel
9 : 9th channel
A : 10th channel
B : 11th channel
C : 12th channel
Fader time
www.m-s-v.eu

DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 20
4-6-4 Fader Time Table
set
50Hz
60Hz
set
50Hz
60Hz
set
50Hz
60Hz
set
50Hz
60Hz
set
50Hz
60Hz
set
50Hz
60Hz
set
50Hz
60Hz
set
50Hz
60Hz
00
NoFade
NoFade
20
01'22
01'08
40
02'43
02'16
60
04'05
03'24
80
05'37
04'41
A0
12'25
10'21
C0
19'13
16'01
E0
26'01
21'41
01
00'03
00'02
21
01'24
01'10
41
02'46
02'18
61
04'07
03'26
81
05'49
04'51
A1
12'37
10'31
C1
19'25
16'11
E1
26'13
21'51
02
00'05
00'04
22
01'27
01'12
42
02'48
02'20
62
04'10
03'28
82
06'02
05'02
A2
12'50
10'42
C2
19'38
16'22
E2
26'26
22'02
03
00'08
00'06
23
01'29
01'14
43
02'51
02'22
63
04'12
03'30
83
06'15
05'12
A3
13'03
10'52
C3
19'51
16'32
E3
26'39
22'12
04
00'10
00'09
24
01'32
01'17
44
02'53
02'25
64
04'15
03'33
84
06'28
05'23
A4
13'16
11'03
C4
20'04
16'43
E4
26'52
22'23
05
00'13
00'11
25
01'34
01'19
45
02'56
02'27
65
04'18
03'35
85
06'40
05'34
A5
13'28
11'14
C5
20'16
16'54
E5
27'04
22'34
06
00'15
00'13
26
01'37
01'21
46
02'59
02'29
66
04'20
03'37
86
06'53
05'44
A6
13'41
11'24
C6
20'29
17'04
E6
27'17
22'44
07
00'18
00'15
27
01'39
01'23
47
03'01
02'31
67
04'23
03'39
87
07'06
05'55
A7
13'54
11'35
C7
20'42
17'15
E7
27'30
22'55
08
00'20
00'17
28
01'42
01'25
48
03'04
02'33
68
04'25
03'41
88
07'19
06'06
A8
14'07
11'46
C8
20'55
17'26
E8
27'43
23'06
09
00'23
00'19
29
01'45
01'27
49
03'06
02'35
69
04'28
03'43
89
07'31
06'16
A9
14'19
11'56
C9
21'07
17'36
E9
27'55
23'16
0A
00'26
00'21
2A
01'47
01'29
4A
03'09
02'37
6A
04'30
03'45
8A
07'44
06'27
AA
14'32
12'07
CA
21'20
17'47
EA
28'08
23'27
0B
00'28
00'23
2B
01'50
01'31
4B
03'11
02'39
6B
04'33
03'47
8B
07'57
06'37
AB
14'45
12'17
CB
21'33
17'57
EB
28'21
23'37
0C
00'31
00'26
2C
01'52
01'34
4C
03'14
02'42
6C
04'35
03'50
8C
08'10
06'48
AC
14'58
12'28
CC
21'46
18'08
EC
28'34
23'48
0D
00'33
00'28
2D
01'55
01'36
4D
03'16
02'44
6D
04'38
03'52
8D
08'22
06'59
AD
15'10
12'39
CD
21'58
18'19
ED
28'46
23'59
0E
00'36
00'30
2E
01'57
01'38
4E
03'19
02'46
6E
04'41
03'54
8E
08'35
07'09
AE
15'23
12'49
CE
22'11
18'29
EE
28'59
24'09
0F
00'38
00'32
2F
02'00
01'40
4F
03'21
02'48
6F
04'43
03'56
8F
08'48
07'20
AF
15'36
13'00
CF
22'24
18'40
EF
29'12
24'20
10
00'41
00'34
30
02'02
01'42
50
03'24
02'50
70
04'46
03'58
90
09'01
07'31
B0
15'49
13'11
D0
22'37
18'51
F0
29'25
24'31
11
00'43
00'36
31
02'05
01'44
51
03'27
02'52
71
04'48
04'00
91
09'13
07'41
B1
16'01
13'21
D1
22'49
19'01
F1
29'37
24'41
12
00'46
00'38
32
02'08
01'46
52
03'29
02'54
72
04'51
04'02
92
09'26
07'52
B2
16'14
13'32
D2
23'02
19'12
F2
29'50
24'52
13
00'48
00'40
33
02'10
01'48
53
03'32
02'56
73
04'53
04'04
93
09'39
08'02
B3
16'27
13'42
D3
23'15
19'22
F3
30'03
25'02
14
00'51
00'43
34
02'13
01'51
54
03'34
02'59
74
04'56
04'07
94
09'52
08'13
B4
16'40
13'53
D4
23'28
19'33
F4
30'16
25'13
15
00'54
00'45
35
02'15
01'53
55
03'37
03'01
75
04'58
04'09
95
10'04
08'24
B5
16'52
14'04
D5
23'40
19'44
F5
30'28
25'24
16
00'56
00'47
36
02'18
01'55
56
03'39
03'03
76
05'01
04'11
96
10'17
08'34
B6
17'05
14'14
D6
23'53
19'54
F6
30'41
25'34
17
00'59
00'49
37
02'20
01'57
57
03'42
03'05
77
05'03
04'13
97
10'30
08'45
B7
17'18
14'25
D7
24'06
20'05
F7
30'54
25'45
18
01'01
00'51
38
02'23
01'59
58
03'44
03'07
78
05'06
04'15
98
10'43
08'56
B8
17'31
14'36
D8
24'19
20'16
F8
31'07
25'56
19
01'04
00'53
39
02'25
02'01
59
03'47
03'09
79
05'09
04'17
99
10'55
09'06
B9
17'43
14'46
D9
24'31
20'26
F9
31'19
26'06
1A
01'06
00'55
3A
02'28
02'03
5A
03'50
03'11
7A
05'11
04'19
9A
11'08
09'17
BA
17'56
14'57
DA
24'44
20'37
FA
31'32
26'17
1B
01'09
00'57
3B
02'30
02'05
5B
03'52
03'13
7B
05'14
04'21
9B
11'21
09'27
BB
18'09
15'07
DB
24'57
20'47
FB
31'45
26'27
1C
01'11
01'00
3C
02'33
02'08
5C
03'55
03'16
7C
05'16
04'24
9C
11'34
09'38
BC
18'22
15'18
DC
25'10
20'58
FC
31'58
26'38
1D
01'14
01'02
3D
02'36
02'10
5D
03'57
03'18
7D
05'19
04'26
9D
11'46
09'49
BD
18'34
15'29
DD
25'22
21'09
FD
32'10
26'49
1E
01'17
01'04
3E
02'38
02'12
5E
04'00
03'20
7E
05'21
04'28
9E
11'59
09'59
BE
18'47
15'39
DE
25'35
21'19
FE
32'23
26'59
1F
01'19
01'06
3F
02'41
02'14
5F
04'02
03'22
7F
05'24
04'30
9F
12'12
10'10
BF
19'00
15'50
DF
25'48
21'30
FF
32'36
27'10
www.m-s-v.eu