Lite-Puter DX-610 User manual

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-I]
1
DX-610/DX-626
6CH.DMX DIMMER PACK
User Manual
Lite
Puter Enterprise Co., Ltd.
Website: www.liteputer.com.tw
E-mailsales@liteputer.com.tw

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-I]
1
INDEX
SAFETY INTRODUCTION .........................................................................................2
The Load Power ..................................................................................................2
Working Environment ..........................................................................................2
Suggested Dimming Lights..................................................................................2
Chapter 1. Introduction ............................................................................................3
1-1 Feature .......................................................................................................3
1-2 Brief device introduction .............................................................................3
1-3 Specification ...............................................................................................3
1-4 Front panel .................................................................................................4
1-5 Output terminal board / Sockets panel........................................................4
1-6 Wiring diagram ...........................................................................................5
Chapter 2. Operation ...............................................................................................6
2 - 1 Standard DMX512 Signal .....................................................................6
2 - 2 DMX start address setting ...................................................................6
2 - 3 Dimming/Switching setting ..................................................................6
2 - 4 Warm up setting (0…6%) .....................................................................7
2 - 5 Channel output status preview ...........................................................7
2 - 6 Manual dimming .....................................................................................7
2 - 7 Display the dimming value of DMX channel, internal temperature.
............................................................................................................................7
2 - 8 DMX status & DMX address ................................................................8
2 - 9 Protocol control ......................................................................................8
Guarantee ...........................................................................................................……9

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
2
SAFETY INTRODUCTION
The Load Power
Please refer to the data we suggested to ensure the normal total working hours
of DX-610/DX-626
1. If DX-610/DX-626 is installed in a rack, please make sure the rack is airy.
Otherwise the machine will become over-heat and result in the
mis-function.
2. DX-610: the max. output of each channel is10A: For testing (DO Not over 30
minutes)
DX-626: the max. output of each channel is 20A: For testing (DO Not over
30 minutes)
3. DX-610: the output of each channel isŊ8A: For several hours use (Theaters,
Stages)
DX-626: the output of each channel is16A: For several hours use
(Theaters, Stages)
4. DX-610: the output of each channel is 8A: Can work for the whole year
without switching off (Hotels, Restaurants, Buildings)
DX-626: the output of each channel is 12A: Can work for the whole year
without switching off (Hotels, Restaurants, Buildings)
Working Environment
1. TemperatureUnder 35°C
2. If the machine is installed in a rack, then the temperature inside the rack
must be under 45°C
3. Humidity40% --- 80%
Suggested Dimming Lights
Incandescent lamps, halogen lamps, low volt halogen lamps with ballast.

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
3
Chapter 1. Introduction
1-1 Feature
6 dimming channels.
Auto tracking of frequency and phase.
Temperature control device: When the temperature is over 45āthe fan will
start automatically.
Auto tracking of frequency: Enables stable dimming output in different
frequencies.
Testing function: Can do test without connecting a console.
Warm-up function to protect the loads. (Warm-up setting 0---6.0%)
1-2 Brief Device Introductions
DX-610: 10A no fuse breaker.
DX-626: 25A no fuse breaker.
Fan for temperature controlling to sink heat and
clean the dust inside. (37CFM X 1)
The front panel can be dismantled easily for
quick repair.
1-3 Specification
Power AC 90-240V, 45-63Hz, 3Ø4W, 1Ø2W
Output DX-610: Maximal output is 10A each channel
DX-626: Maximal output is 20A each channel
(Please refer to the user manual)
DMX signal output/ input DMX512/ 1990
DMX signal connector XLR 5Pin, RJ11-6p4c phone jack
Analog signal power input DC 0-10V
Analog input channel 6 channels
PIN 1~6CH1~6, PIN 7NC
PIN 8V+12V OUT, PIN 9GND
Analog signal connector D-Type Plug 9 Pin(F)
Dimension 482(W) x 88(H) x 300(D)mm
Location 19" 2U standard rack
Weight 8Kg

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
4
1-4 Front Panel
7 8 6 5 4 3 2 1
(1) Power on/ off switch (5) Function Key
(2) DMX OUT/ IN (5 pin) (6) Dimming VR of Channel 1- 6
(3) DMX IN (RJ11, phone jack) (7) No fuse breaker (Channel 1-3)
(4) LED display/ function keys (8) No fuse breaker (Channel 4-6)
1-5 Output Terminal Board / Sockets Panel
TERMINALTYPE
910
11 12 13
(9) DMX connector (RJ11, phone jack)
(12) Output terminal board (External
power no fuse breaker is necessary when
mounting.)
(10) DMX IN (XLR-3 pin) (13) Power input terminal board.
(DX-610: 20A Single phase;
DX-626: 40A Single phase)
(11) DMX OUT (XLR-3 pin)

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
5
AMERICAN TYPE
Output sockets (DX-610: 10A each channel; DX-626: 15A each channel, e
xternal
power no fuse breaker is necessary when mounting.)
SCHUKO TYPE
Output sockets (DX-610: 10A each channel; DX-626: 16A each channel, e
xternal
power no fuse breaker is necessary when mounting.)
1-6 Wiring Diagram
PS.: There are ‘3 PHASES 3 WIRES’ and ‘SINGEL PHASE 3 WIRES’ as option.

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
6
Chapter 2. Operation
2 - 1 Standard DMX512 Signal
2 - 2 DMX Start Address Setting
STEP-1 holdingDMX, press▲or▼to find the start address.
▲: move 1 number forward : up to Channel 512.
▼:move 1 number backward :down to Channel 1.
2 - 3 Dimming/Switching Setting
STEP-1 pressDMXkey into DMX status.
STEP-2 press and hold theFNCkey for 3 sec.
STEP-3 pressFNCkey to select channel.
STEP-4 press▲or▼to select dimming mode or switching mode.
DX-626 is a 6 channel dimmer pack so when setting this unit:
1 as d.001, the output is from Channel 1Channel 6.
2 as d.007, the output is from Channel 7Channel 12.
3 It is allowed for setting more than 1 piece of DX-626 at the same start
address.
Default settingAll channel are
dimming mode
This point is flashing when
receiving DMX signal.

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
7
(Dimming) (Switching)
2 - 4 Warm Up Setting (0…6%)
STEP-1 pressFNCkey .
STEP-2 pressFNCkey to select the setting channel, EX :select channel 1
STEP-3 press▲,▼key to adjust.
2 - 5 Channel Output Status Preview
STEP-1 Enter to DMX status and pressDMXkey.
STEP-2 press▲or▼to preview.
2 - 6 Manual Dimming
STEP-1 PushVR1-VR6to do the prompt dimming output of individual channel.
When there is another signal inputting from a console, it will take the higher value as
the output.
2 - 7
Display The Dimming Value of DMX Channel,Internal Temperature.
PressLto display the dimming value of DMX channel.
PressTto display the internal temperature.
Channel 1 set on 6% for warm up.

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
8
2 - 8 DMX Status & DMX Address
a.pressDMXto DMX status.
b.10 minutes unused of unit, the DMX will activate to DMX status.
2 - 9 Protocol Control
When the protocol control turn on, it only receive the DMX signal whose break width
range from 88us to 230us.
STEP-1 PressFNCand LED displays as below.
or
STEP-2 Pressand LED displays as below,
Protocol control is ON.
STEP-3 Pressand LED displays as below,
Protocol control is OFF.

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
9
Guarantee
1. Lite-Puter is only responsible for DX-610/DX-626 itself.
2. Lite-Puter guarantees to keep Lite-Puter’s fault products caused by
techniques, materials and any other logical reasons in good repair for free
within a year since the distributing date.
3. We do not offer door-visiting service. If the trouble appears in
Lite-Puter’s products, please deliver the equipment to local distributors or
Taipei headquarter.
*** Special Statement***
Any fault caused by false usage, imprudence (collision or
inadequate installation) or force majeure factors are not in
Lite-Puter’s service.
Revision Record
Version Record
A First version
H change pictures
I change pictures,1-1,1-4
Issued on: May, 2010

ISO 9001 CERTIFIED
www.liteputer.com.tw
Lite-Puter
DX-610/626 [EUM-
]
10
World Headquarter
Lite-Puter Enterprise Co., Ltd.
Address: 9F, No. 196, Sec. 3, Da Tung Rd., Shijr City, Taipei, Taiwan
Zip Code: 22103
Tel: +886-2-86472828
Fax: +886-2-86472727
Website: www.liteputer.com.tw
E-mail: sales@liteputer.com.tw
Shanghai Factory:
Lite-Puter Technology (Shanghai) Co., Ltd.
Address: Building B5, No. 298, Lane 3509, Hongmei S. Road, Shanghai, China
Zip Code: 201108
Tel: +86-21-54408210
Fax: +86-21-64978079
Shanghai Sales Center:
Address: Room 701, Building Gem, No. 487, Tianlin Road, Shanghai, China
Zip Code: 201103
Tel: +86-21-33674316/33674850
Fax: +86-21-33674013
Website: www.liteputer.com.cn