2 | Instructions for use | Marina basic & Marina deluxe
Marina basic hydraulic: 6100 2000
Basic UDI-DI: 872025610348661002000PU
Marina basic electric: 6100 2050
Basic UDI-DI: 872025610349361002050P3
Instructions for use
Marina basic & Marina deluxe
Marina basic (excl. mattress) : 6100 2000 & 6100 2050
Marina deluxe (excl. mattress) : 6100 2010 & 6100 2060
Shower trolley
Marina deluxe hydraulic: 6100 2010
Basic UDI-DI: 872025610350961002010KT
The images above shows the trolleys with mattress. The length of the mattress
determines the size of the lying surface. The following mattresses are available:
Marina deluxe electric: 6100 2060
Basic UDI-DI: 872025610351661002060K2
Article. No. Gtin Description Inside length Inside width
6720 0010 8720256103523 Mattress 186 cm / 73.2 inch 170 cm / 66.9 inch 70 cm / 27.6 inch
6720 0020 8720256103530 Mattress 206 cm / 81.1 inch 190 cm / 74.8 inch 70 cm / 27.6 inch
6720 0030 8720256103547 Mattress 226 cm / 89 inch 210 cm / 82.7 inch 70 cm / 27.6 inch

Marina basic & Marina deluxe | Instructions for use | 3
Important:
Read these instructions carefully before using the Marina basic / Marina deluxe!
Date first used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manufacturer
Lopital Nederland B.V.
Laarakkerweg 9
5061 JR Oisterwijk
T +31 (0)13 5239300
www.lopital.com
All of the aids produced by Lopital fulfil the following norms for medical products Class 1 (MDR (EU) 2017/745).
Explanation of symbols in ‘instructions for use’ and on labels
Note Follow the instructions
for use
Direct current 24V DC Read cleaning and
disinfecting protocol
Date of production Antibacterial
Maximum load Temperature
Global trade identification
number Air pressure
Serialnumber Humidity level

4 | Instructions for use | Marina basic & Marina deluxe
Contents
1. Introduction ..............................................................................5
1.1. Introduction ..............................................................................5
1.2. Safety .........................................................................................6
1.3. Warranty....................................................................................8
2. Use .............................................................................................8
3. Operation ................................................................................14
3.1. Wheel blocking .......................................................................14
3.2. Side rail ....................................................................................14
3.3. Moving upwards/ downwards .............................................15
3.4. Backrest adjustment ..............................................................17
3.5. Tilting (Anti-trendelenburgstand) ........................................17
3.6. Waterdrainage ........................................................................18
3.7. Changing battery....................................................................18
3.8. Charging battery.....................................................................19
4. Safety functions .................................................................... 20
4.1. Emergency stop..................................................................... 20
4.2. Emergency lowering button ................................................ 20
5. Cleaning and maintenance .................................................. 21
6. Environmental conditions .................................................... 23
7. Removal of parts ................................................................... 23
8. Technical specifications ........................................................ 23
8.1. Structure ................................................................................. 23
8.2. Drive ........................................................................................24
8.3. Dimensions .............................................................................24
8.4. Length adjustment .................................................................27
8.5. Replacement of parts ............................................................27
9. Checklist for technical problems ......................................... 29
10. Relation with other supports ............................................... 30
11. Electromagnetic compatibility ..............................................31

Marina basic & Marina deluxe | Instructions for use | 5
1. Introduction
1.1. Introduction
The Marina basic / Marina deluxe shower trolley is a medical device for caring for
and washing clients in an ergonomically responsible manner. Comfort is the primary
consideration for both the client and the caregiver. The Marina basic / Marina deluxe
comprises a mobile base frame and a height-adjustable supporting surface with a
soft mattress. The Marina deluxe also has a back adjustment. There are no essential
performances.
The frame of the Marina basic / Marina deluxe has an antibacterial coating. The coating
contains silver ions. Antibacterial coating based on silver ions prevents dangerous
micro-organisms such as bacteria, fungi and algae multiply and spread. The effectiven-
ess was confirmed in several tests. Germs were demonstrably reduced in a short time
to 99.99%. The coating only affects bacteria that are found on the surface and not on
airborne micro-organisms. The coating protects users or others from disease-causing
bacteria, germs, viruses or other harmful organisms. On a dirty surface, the coating
loses its antibacterial properties. So proper cleaning and disinfection is still a must.
The Marina basic / Marina deluxe is multi-functional in use and corresponds to the use
of other devices such as beds, wheelchairs and shower chairs, hoisting equipment and
sliders.
The expected technical life of the Marina basic / Marina deluxe is 10 years, assuming
it is cleaned daily and regularly maintained according to the maintenance schedule
supplied (See chapter 5. Cleaning and maintenance).
The Marina basic / Marina deluxe is a class 1 medical device with CE-marking. This
marking corresponds with regulation MDR (EU) 2017/745. The Marina basic / Marina
deluxe has been tested for electro-magnetic radiation according to the IEC 60601-1-2.
The length of the mattress determines the size of the lying surface. The following
mattresses are available:
- 186 cm / 73.2 inch
- 206 cm / 81.1 inch
- 226 cm / 89 inch

6 | Instructions for use | Marina basic & Marina deluxe
1.2. Safety
A failure to comply with the following safety points and the further definitions
in these instructions for use could lead to hazardous working situations. Please
read carefully before use.
Use
· Before you start work with the Marina basic / Marina deluxe, check that there has
been a fully loaded battery placed in the controlbox (for electric adjustable Marina
basic / Marina deluxe).
· The electrically powered Marina switches to standby after a few seconds, when not in
use.
· Make sure that the brakes are applied before transferring clients.
· Notify the client before moving the Marina basic / Marina deluxe.
· Be aware of obstacles and persons in the immediately vicinity when moving or
adjusting the trolley.
· Make sure that the client always places his / her arms / legs inside the mattress in
order to avoid anything coming jammed.
· Only relocate and move the Marina basic / Marina deluxe in a physical comfortable
position.
· When moving the Marina basic / Marina deluxe, do not adjust upwards or downwards.
· Always close the siderails before moving the Marina basic / Marina deluxe with client
(manoeuvring, upwards or downwards).
· It is not permitted to load the Marina basic / Marina deluxe with more than 227 kg /
500 lbs.
· The Marina basic / Marina deluxe is only suitable for moving and caring for one
person.
· Use only original parts, supplied by Lopital. The use of non-original parts can cause
dangers.
· The use of components (chargers, cables, actuators, batteries, etc.) that have not been
supplied by Lopital may result in increased emissions or decreased immunity of the
Marina basic / Marina deluxe (for electric adjustable Marina basic / Marina deluxe).
· Use the Marina basic / Marina deluxe in a clean and tidy working environment.
· Charge battery box in a well-ventilated, dry space.
· Swimming pool locations are not considered to be ‘normal conditions’ and will
substantially shorten the lifespan of certain components.
· The Marina basic / Marina deluxe may not be raised by the upper surface.
· The Marina basic / Marina deluxe cannot be used on a surface with a gradient over
5 degrees laterally.

Marina basic & Marina deluxe | Instructions for use | 7
· The Marina basic / Marina deluxe cannot be used on a surface with a gradient of
over 10 degrees forwards / backwards.
· The Marina basic / Marina deluxe may only be used indoors.
· Don’t touch the batteryterminals and the client at the same time.
· Portable and mobile RF communication equipment can affect medical devices.
Portable RF communications equipment (including peripherals such as antenna
cables and external antennas) should be used no closer than 30 cm (12 inches) to
any part of the Marina deluxe / Marina basic electric including cables specified by
the manufacturer. Otherwise, degradation of the performance of this equipment
could result.
· Medical electrical devices involve special EMC precautions and must be used as per
the EMC information outlined in the instructions for use.
· The emissions characteristics of the Marina basic / Marina deluxe electric make it
suitable for use in industrial areas and hospitals (CISPR 11 class A). If it is used in
a residential environment (for which CISPR 11 class B is normally required) this
equipment might not offer adequate protection to radio-frequency communication
services. The user might need to take mitigation measures, such as relocating or
re-orienting the equipment.
· The trolley must not be used adjacent to or stacked on other products. However,
should that be necessitated, it must be checked whether the trolley functions
normally in this configuration too.
Maintenance
· If the charger or cable become damaged, they must be replaced (for electric
adjustable Marina basic / Marina deluxe.
· If the mattress is damaged, replace the mattress for hygiene reasons.
· It is recommended to replace the mattress after 5 years for hygiene reasons.
· The Marina basic / Marina deluxe must be serviced and inspected at least once a year.
· No modification of the Marina basic / Marina deluxe is allowed, except length
adjustment according to the instructions of Lopital.
· If the Marina basic / Marina deluxe is adjusted in length, appropriate inspection must
be conducted to ensure continued safe use of the shower trolley.
· Servicing and maintenance of the Marina basic / Marina deluxe may only be carried
out by persons with a technical background, who have experience in servicing and
maintaining similar products.
· Constructive components of the Marina basic / Marina deluxe may only be replaced
by suitably authorised personnel.

8 | Instructions for use | Marina basic & Marina deluxe
· The Marina basic / Marina deluxe shall not be serviced or maintained while in use
with a client.
· If erroneous use, transport, an accident or improper maintenance leads to deformation
of the Marina basic / Marina deluxe, it may no longer be used and you must contact
the supplier or manufacturer.
In the event of breakdowns, you must contact Lopital or your local supplier.
E-mail: in[email protected]
The Marina basic / Marina deluxe may only be operated by persons who have
experience working with the target group and have followed the Instruction /
trainings video’s on the website of Lopital.
The Marina basic / Marina deluxe has been developed and produced for use in a
professional care environment.
Making changes to the construction could affect the safety of the Marina basic
/ Marina deluxe. This will also lead to Lopital’s liability and warranty conditions
being invalidated. As a result, the Marina basic / Marina deluxe will no longer
comply with the regulation MDR (EU) 2017/745 for medical devices.
1.3. Warranty
All Lopital products are supplied with a 2-year warranty, on construction and / or
material faults, unless otherwise stated. In the event of varying warranty terms, the
exact period will be indicated on your invoice; this also serves as the warranty itself.
Components and batteries that are subject to wear and tear will not fall under warranty
unless there are clear construction and / or material faults.
2. Use
The images below shows the components of the Marina basic / Marina deluxe. The
detachable parts of the trolley are the mattress and the batterybox.

Marina basic & Marina deluxe | Instructions for use | 9
Mattress
Mattress
Drainage hose
Drainage hose
Frame
Frame
Gasspring Anti-
trendelenburg
Gasspring Anti-
trendelenburg
Lever tilting
Lever tilting
Locking side rail
Locking siderail
Adjustable siderail
Adjustable siderail
Hydraulic pump
Actuator high/low
Foot pedal
(high/low)
Swivel wheel Ø15 cm/
5.1 inch double braking
Swivel wheel Ø15 cm/
5.1 inch Double braking
Marina basic – hydraulic adjustable (art. no. (excl. mattress): 6100 2000)
Marina basic – Electric adjustable (art. no. (excl. mattress): 6100 2050)
Control box +
battery box
Hand control
(TMH3)
battery box
(BAT 4259-002)

10 | Instructions for use | Marina basic & Marina deluxe
Mattress
Drainage hose
Frame
Lever backrest
adjusting
Lever tilting
Locking siderail
Adjustable siderail
Hydraulic pump
Foot pedal
(High/low)
Swivel wheel
Ø15 cm/ 5.1 inch
Pedal semi-central
brake & directional wheel
Marina deluxe – Hydraulic adjustable (art. no. (excl. mattress): 6100 2010)
Gass spring Anti-trendelenburg

Marina basic & Marina deluxe | Instructions for use | 11
Mattress
Drainage hose
Frame
Lever tilting
Locking siderail
Adjustable siderail
Actuator high/low
Marina deluxe – Electric adjustable (art. no. (excl. mattress): 6100 2060)
Hand control
(TMH3)
Battery box
(BAT 4259-002)
Gasspring Anti-trendelenburg
Control box+battery box
Swivel wheel
Ø15 cm/ 5.1 inch
Pedal semi-central
brake & directional wheel

12 | Instructions for use | Marina basic & Marina deluxe

Marina basic & Marina deluxe | Instructions for use | 13

14 | Instructions for use | Marina basic & Marina deluxe
3. Operation
3.1 Wheel blocking
Marina basic
The Marina basic is equipped with 4 swivel wheels.
· The brake can be applied on the Marina basic by pushing
the blue lip (1) on the wheel downwards (See figure 1).
· In order to take the Marina basic off the brake, the same
lip on the wheel must move upwards by tapping the upper
side of the lip (2) (See figure 2).
Marina deluxe
The Marina deluxe is equipped with a semi-central braking
system, so you can brake 2 wheels at the same time. The
semi-central control pedal for the brakes is the pedal at the
head end and the foot end on both sides of the trolley (See
figure 2).
· The brake on the Marina deluxe can be applied by moving
the inside of the pedal at the head and foot end down-
wards, using your foot (1)
· To release the Marina deluxe off the brakes, the pedal must
be moved upwards to a horizontal position with your foot.
· The swivel wheel is disengaged by moving the outside
of the pedal at the head and foot end downwards with your foot.
· The swivel wheel is engaged by moving the pedal back
into the horizontal position with your foot.
3.2. Side rail
· The Marina basic / Marina deluxe is equipped with aluminium side rails that can be
collapsed against the edge of the bed-base so that sliding transfers can be carried out.
· The side rail is equipped with safeguards so that the client cannot raise the side rails
themselves (See figure 3).
· Before the side rail is collapsed downwards, the safeguard must be unlocked.
· Unlock the safeguard by using one hand to pull the protruding handle and rotating the
side rail with your other hand (2) (See figure 3).
· With folded side rails, the caregiver can lean against the mattress in the middle to
better care for the patient.
Figure 1 Wheel blocking.
2
1
Figure 2 Wheel blocking.
12

Marina basic & Marina deluxe | Instructions for use | 15
· Turn the side rail upwards again to close the side rail (see figure 4). The side rail locks
automatically.
· The side rail can be placed in 2 positions, wide and narrow. When you fold the side
rail upwards, the side rail is first locked in the wide position (see figure 5). By pulling
the handle of the lock (see figure 4) you can move the side rail further back to its
narrow position.
3.3. Moving upwards/ downwards
Hydraulically adjustable versions
Moving upwards
· If the client is lying on the shower trolley, first put the
brake on the wheels and then move the trolley upwards.
· The trolley is moved upwards by pressing the long part of
the foot pedal slowly and evenly (See figure 6).
· During use of the pedal, the carer will stand by the long
edge of the Marina so that the carer cannot twist their
upper body away from their feet.
· During the upward movement, maintain contact with the
client.
Moving downwards
· The trolley is lowered by pressing the short part of the
foot pedal (See figure 7).
· The trolley lowers under the influence of gravity. The
lowering speed can be steadied by keeping the pedal
gently depressed.
· During the downward movement, maintain contact with the client.
Figure 4 Side rail down.
2
1
Figure 5 Side rail wide.Figure 3 Side rail.
2
1
Figure 6 Moving upwards.
Figure 7 Moving downwards.

16 | Instructions for use | Marina basic & Marina deluxe
Electrically adjustable versions
Moving upwards
· If the client is lying on the shower trolley, first put the
brake on the wheels and then move the trolley upwards (1)
(See figure 8).
· Move the trolley upwards by pressing the button that
shows an ‘up’ arrow. The trolley will then immediately
move upwards (See figure 8).
· You can stop the movement whenever you like by taking
your finger off the button.
· During the upward movement, maintain contact with the
client.
· If the remote control is not being used, it can be hung on
the side rail or on the push-bar.
· Ensure that the curly cable on the operating device does
not get jammed.
Moving downwards
· Move the trolley downwards by pressing the button that
shows a ‘down’ arrow. the trolley will immediately move
downwards (2) (See figure 8).
· You can stop the movement whenever you like by taking
your finger off the button
· During the downward movement, maintain contact with
the client.
When the hand control is lost or defect, the shower trolley
can be adjusted in height by pressing the buttons on the
control box (see figure 9).
Before moving the trolley, check to ensure there are no persons or objects in
the immediately vicinity of the trolley.
Figure 9 Control box.
Figure 8 Hand control.
2
1

Marina basic & Marina deluxe | Instructions for use | 17
3.4. Backrest adjustment
The Marina deluxe is equipped with a back adjustment.
The back adjustment is available with an electrical or
mechanical drive.
Mechanical back adjustment
(hydraulic adjustable Marina deluxe)
The back can be moved upwards by means
of the handle on the side of the trolley (see
figure 10). Release the handle when the back
is in the correct position. To move the back
down, the hendle must be pressed again.
Electric back adjustment
(electrical adjustable Marina deluxe)
The stepless electric back adjustment is
operated by pressing the buttons on the hand
control (see figure 11). Release the button
when the backrest is in the correct position.
3.5. Tilting (Anti-trendelenburgstand)
· In order to remove water from the mattress during or af-
ter showering, the bed base on the Marina basic / Marina
deluxe can be tilted.
· Turn the lever on the upper frame, under the head end,
outwards in order to position the bed base in the drainage
position.
· This control can be found on both sides of the trolley.
· Turn the lever inwards before restoring the bed base to its
horizontal position.
3.6. Waterdrainage
Water is drained away from the Marina basic / Marina de-
luxe via a drainage hose. To do this, remove the hose from
the recess (1) and route it to the lowest possible drainage
point. Always click the hose into the recess of the lying plate
during transport, in connection with leaking and dripping.
Figure 10 Back adjustment
mechanical.
Figure 12 Anti-trendelenburg.
Figure 13 Waterdrainage.
Figure 11 Back adjustment elektrical.
1

18 | Instructions for use | Marina basic & Marina deluxe
3.7. Changing battery
(Only electrical adjustable Marina basic / Marina deluxe).
The Marina basic / Marina deluxe is an electrically
adjustable high-low trolley and works on a battery.
The battery is located at the head-end of the trolley.
(See figure 14).
· There is a battery indication on the hand control (see figure
15).
· Charge the battery on the chargerstation (see figure 16).
· In order to remove the battery, use one hand to unlock the
catch (1) on the battery, then slide the battery to the right
(2) (see figure 14).
· To install the fully charged battery, it must first be
positioned next to the electronic housing and then
clicked into the holder.
· You can better insert and remove the battery when the
back adjustment is in the highest position (Only Marina
deluxe).
Make sure that the Marina basic / Marina deluxe is
always ready for use by having a fully charged reserve
battery on standby. If this is not the case, lift the
client from the stretcher with a patient hoist or
manually with at least 2 persons.
When the battery box is fully charged, it will be able to
perform the high / low movement in combination with
the back adjustment approximately 45 times.
After 4/5 years it is recommended to replace the
battery box.
Only use batteries that are supplied with the Marina
basic / Marina deluxe. The batterybox that is used
for the Marina basic/Marina deluxe is the ‘Ti-motion
BAT-4259-002’ 2.9 Ah, 24 V.
Figure 14 Battery.
Figure 15 Battery indication
hand control.
2
1
Figure 16 Chargestation.
Figure 17 chargestation with
battery.

Marina basic & Marina deluxe | Instructions for use | 19
3.8. Charging battery
(Only electrical adjustable Marina basic / Marina deluxe). .
· Place the battery to be charged on the battery chargestation (see figure 17).
· A green light indicates that the battery charger is switched.
· The charged battery can remain on the battery charger without being damaged.
· In order to remove the battery, use one hand to unlock the catch on the battery and
the other to support the battery itself.
Charge batteries that are not used, once every six months to avoid damage.
Charging the batteries before they are completely empty will extend their
lifespan.
The expected battery lifespan depends on following the manufacturer’s
charging instructions.
The charger that is used for the Marina basic / Marina deluxe is the ‘Ti-motion
TBC 2’.
Charge batteries in a well-ventilated, dry space.
4. Safety functions
4.1. Emergency stop
(Only electric adjustable Marina basic / Marina deluxe).
On the side of the head-end, there is an emergency stop. Operate this button in an
emergency, if the upward or downward movement must be stopped immediately. Once
the emergency stop is pressed, the electronic controls will stop working. The emer-
gency stop interrupts all power.
Fully charged.
1/3 capacity,
Charging advised.
Charging required,
An acoustic signal sounds
(red light).2/3 capacity.

20 | Instructions for use | Marina basic & Marina deluxe
Operation may be continued once the situation is stable
again. Turn the emergency stop a quarter turn to unlock it
again (See figure 18).
First check to ensure the hazard has been removed or
the problem has been resolved, before resetting the
emergency stop button.
If the button is activated, no leds will light up on the
hand control.
4.2. Emergency lowering button
(Only electric adjustable Marina basic / Marina deluxe).
If the handcontrol stop working and the trolley is in a raised
position, it can be lowered using the emergency lowering
button. This button is located on the controlbox (See figure
19).
First check to ensure that the emergency button has not been
pressed!
• Press the emergency lowering button (See figure 19).
The shower trolley will now return to the lowest position (make sure no persons or ob-
jects are under the stretcher). Take the client from the trolley and make sure the device
is not used until it has been repaired. Place the trolley in a safe place and indicate that it
is out of order.
5. Cleaning and maintenance
The Marina basic / Marina deluxe must be cleaned after every use, with water and
regular household cleaning agents. Do not use any abrasive or other aggressive
cleaning products. If necessary, the mattress can be disinfected with a solution of
70% ethanol or propanol.
For the best and most efficient cleaning of the mattress and the bed base, the mattress
can be lifted up and removed. Dry the plate on which the mattress lies.
Figure 18 Emergency stop.
Figure 19 Emergency lowering
Button
This manual suits for next models
10
Table of contents
Other lopital Medical Equipment manuals

lopital
lopital Flexo User manual

lopital
lopital Amfora User manual

lopital
lopital Amfora 6200 4010 User manual

lopital
lopital Marina 6100 2300 User manual

lopital
lopital Marina User manual

lopital
lopital Elexo 5100 User manual

lopital
lopital Lotus User manual

lopital
lopital Amfora Technical manual

lopital
lopital Reflex 5100 5600 User manual

lopital
lopital Amfora User manual