PROBLEM POSSIBLE CAUSE SOLUTION
DOOR WILL NOT LOCK NO DC VOLTAGE TO LOCK. LOOSE WIRE ON
TERMINAL STRIP
CHECK POWER SUPPLY AND WIRING TO
MAGNETIC LOCK
REDUCED HOLDING FORCE BAD PHYSICAL CONTACT BETWEEN ARMATURE PL ATE AND FACE OF
MAGNET. INCORRECT VOLTAGE JUMPER SET TING
ENSURE MATING SURFACES ARE CLEAN AND IN PROPER ALIGNMENT AND THE
ARMATURE PLATE FLOATS FREELY.
CHECK MAGNETIC LOCK FOR LOW VOLTAGE OR WRONG VOLTAGE SETTING
DELAY IN DOOR RELEASE CIRCUIT SWITCH IS NOT BETWEEN MAGNETIC LOCK AND POWER
SOURCE. SECONDARY DIODE INSTALLED ACROSS MAGNETIC LOCK
RE-WIRE CIRCUIT SWITCH BETWEEN MAGNETIC LOCK AND POWER SOURCE.
REMOVE ANY INSTALLED DIODE. VOLTAGE SPIKE PROTECTION IS ON THE PCB.
LED STATUS IS INCORRECT
MISALIGNMENT OF ARMATURE PLATE.
REED SWITCH LOCATED IN WRONG POSITION IN MAGNETIC BLOCK.
INCORRECT VOLTAGE SETTING
CHECK ALIGNMENT OF ARMATURE PLATE.
ADJUST JUMPER TO CORRECT VOLTAGE.