LST BC016-2 User manual

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
BC016-2_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.
F ire Detection Control Panel
BC016-2 with Evacuation Functions
• For small and mid–sized systems
• Addressable conventional technology
with a maximum of 16 zones
• Up to 8 evacuation circuits
• Menu-driven operation
• Free parameter setup via PC
software or operating fi eld
• Factory settings allow for easy
commissioning
• EN 54/VdS-certifi ed
Fire is a permanent threat to life and property. There-
fore, immediate response to a fi re is imperative. The
main objective of the fi re detection control panel Series
BC016 is to alarm and to react in time and, conse-
quently, save lives and protect property. For decades
LST have focused their aims to undertaking unrivaled
efforts in order to realize new innovations in the security
area. Research, development and production are loca-
ted within LST premises, thus guaranteeing fl exible and
reliable individual solutions.
Using a powerful processor system, display texts, and a
large number of integrated functions, the fi re detection
control panels Series BC016 ensure topmost effi ciency
and speed – prerequisites for saving lives and minimi-
zing damage to property.
Description
Fire detection control panel BC016-2 in design and
function corresponds to fi re detection control panel
BC016-1. In addition, the BC016-2 has the possibility
to operate up to eight alarming devices as evacuation
circuits directly via the expanded keypad of the control
panel. These evacuation circuits can be actuated either
dependent of the alarm situation of the detector zone or
by a superordinate danger detection device.
Using the expanded keypad, you can manually activate
or deactivate the alarming devices that have been para-
meterised as evacuation circuits independent from the
alarm situation on the control panel. This way, the user
can manually start or terminate an evacuation alarm on
the fi re detection control panel without prior alarm of a
fi re detector. In the LED fi eld, the fi rst zone displays are
automatically used for displaying the operating conditi-
ons of the evacuation circuits.
For security reasons a two-button operation must be
performed to activate an evacuation circuit.
The physical outputs for the control and monitoring of
the alarming devices are provided by optional modules
(e.g., siren connection module SZ58-3).
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
BC016-2_DBL_LST_EN_0804.PDF • PAGE 2
ABuilding Safety. Building Security.
Clear Concept
The fi re detection control panel BC016-2 has been desi-
gned for use in small and mid-sized systems and alrea-
dy in its basic version provides the following features:
• 8 conventional detector lines permit the connection
of automatic detectors and manual call points in con-
ventional technology as well as special detectors with
contact output. Individual detector identifi cation can
be achieved by means of an optional address modu-
le.
• A slot for connecting the Detector Zone Extension
MGE8-1 is available for the extension to 16 conventi-
onal detector lines.
• Dry relay outputs indicate the alarm and fault condi-
tions on the control panel. In addition, 16 open-coll-
ector outputs, two auxiliary inputs, and an additional
relay output are available for general applications.
• Up to 8 alarming devices can be operated as evacu-
ation circuits directly via the expanded keypad of the
fi re detection control panel.
• The optional Fire Brigade Interface FWI016-1 allows
for the connection of two independent transmitting
devices for a direct interconnection to a designated
alarm respondent (e.g., the fi re brigade) as well as
for the connection of a country-specifi c fi re brigade
control unit.
• Outputs with open parameters and logical combina-
tions of detector zones for the activation of external
controls and alarming devices allow for a maximum
of fl exibility. Thus, no additional expenses arise for
external relays, logic gates or timers. Using these
individual combinations of different types of detec-
tors, even fi re protection strategies under the most
diffi cult circumstances can be combined into a reaso-
nable concept.
• The LC text display shows all present events with
date and time. This allows for quick and targeted
reaction in the event of a fi re as well as for easy main-
tenance.
• An event memory allows for the display of the latest
200 events at any time, including all required informa-
tion. Thus, all system conditions and user operations
that occurred are documented in a clearly laid out
way.
• A possible breakdown of the central processing board
is securely detected and displayed by the system.
• The processor-monitored power supply ensures per-
manent surveillance and charging of the batteries.
This way, even during a power failure the untroubled
and uninterrupted operation (for more than 72 hours
depending on the design) is guaranteed.
• Three hierarchized authorization levels for operation
and parameterisation facilitate a high degree of secu-
rity against unauthorized access.
• The control panel is easily operated menu-driven via
the display and operating fi eld. Clear instructions on
the display guide the user during commissioning,
operation and maintenance.
• The parameter data can be entered either via the
display and operating fi eld or, in a more comfortable
way, created by means of the PC software PARSOFT-1
and loaded into the control panel. Thus, a quick and
effi cient transfer of the system confi guration into the
control panel is guaranteed.
• After activation, the control panel is immediately rea-
dy for operation due to the practical factory setting.
This guarantees easy and time-saving commissio-
ning.
The extremely fl at wall mount cabinet allows for an easy
mounting in virtually any place of the building. Thanks to
its modern, ageless design, architectural requirements
and demands of the respective regulations are ideally
combined. The compact design allows for the accom-
modation of the optional Detector Zone Extension, the
Fire Brigade Interface, the Serial Interface Module, up
to 3 auxiliary modules (e.g., relay module, siren connec-
tion module) and batteries up to 22Ah apart from the
central processing board in the standard case. Series
BC016 thus stands for modularity and easy expansion.
This product complies with all relevant standards of
EN 54 and is VdS-certifi ed. In addition, the product also
holds several country-specifi c approvals and certifi ca-
tes. LST‘s high quality level is secured by a permanent-
ly monitored quality management system certifi ed by
ISO 9001.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
BC016-2_DBL_LST_EN_0804.PDF • PAGE 3
ABuilding Safety. Building Security.
Permanent Connection
Specifi cations
Mains voltage 230VAC +10/-15%, 50Hz
Output/nominal voltage typ. 28VDC
Output peak current max. 1.8A
Own current consumption at 24V typ. 70mA (without optional componentries)
Ambient temperature -5°C to +50°C
Relative humidity 95% (no condensation)
Dimensions W × H × D 380 × 480 × 83 (mm)
Colour gray-white, RAL 9002
Weight without accumulator approx. 5kg
Approvals (EN 54-2, EN 54-4) VdS G205023
FT 14/439/04 (Austria),
Part No. 210122
Order name Fire and Evacuation Panel BC016-2/INT1
A variety of peripheral devices can be connected to the
fi re detection control panel BC016-2:
• Fire brigade key safe
• Fire brigade control unit
• Acoustic and optical signaling devices
• External protocol printer
• Remote indication unit
• Actuations
• Modules for remote parameterisation and remote
maintenance via computer newtork, modem or GSM
connection
– and much more.

Other LST Control Panel manuals

LST Series BC216 User manual

LST

LST Series BC216 User manual

LST 130 User manual

LST

LST 130 User manual

LST ABF216-1 User manual

LST

LST ABF216-1 User manual

LST Vds EN 12094-1 User manual

LST

LST Vds EN 12094-1 User manual

LST BC016-1 User manual

LST

LST BC016-1 User manual

LST LC216 Series User manual

LST

LST LC216 Series User manual

LST BC06 Series User manual

LST

LST BC06 Series User manual

LST BCE216 BC216-2 User manual

LST

LST BCE216 BC216-2 User manual

LST Extinguishing Control Panel BC06-2EXT User manual

LST

LST Extinguishing Control Panel BC06-2EXT User manual

LST BC216-1S User manual

LST

LST BC216-1S User manual

LST Vds BC216-1 User manual

LST

LST Vds BC216-1 User manual

Popular Control Panel manuals by other brands

LCI Smart Jack installation manual

LCI

LCI Smart Jack installation manual

Ness D16 Installation & programming manual

Ness

Ness D16 Installation & programming manual

Russound SaphIR K2 Specifications

Russound

Russound SaphIR K2 Specifications

Russound TS3 installation manual

Russound

Russound TS3 installation manual

Vallox MyVallox Touch manual

Vallox

Vallox MyVallox Touch manual

Vacon 7-segment Control Panel manual

Vacon

Vacon 7-segment Control Panel manual

DoorHan PCB-SW 24 Programming instructions

DoorHan

DoorHan PCB-SW 24 Programming instructions

Extron electronics IPCP Pro Series Setup guide

Extron electronics

Extron electronics IPCP Pro Series Setup guide

ENDA EOP4-070 Series installation instructions

ENDA

ENDA EOP4-070 Series installation instructions

Bosch FPA-1000-UL quick guide

Bosch

Bosch FPA-1000-UL quick guide

See Water Oil Smart OSSIM-30 Installation and operation manual

See Water

See Water Oil Smart OSSIM-30 Installation and operation manual

Kramer RC-76M user manual

Kramer

Kramer RC-76M user manual

nilan Compact S CTS 602 user manual

nilan

nilan Compact S CTS 602 user manual

Chamberlain LiftMaster Professional CB22 Instructions and electrical set up

Chamberlain

Chamberlain LiftMaster Professional CB22 Instructions and electrical set up

GE Concord express instruction manual

GE

GE Concord express instruction manual

Burster 9180 instruction manual

Burster

Burster 9180 instruction manual

Satel Versa Plus Quick user manual

Satel

Satel Versa Plus Quick user manual

Tiandy 5820B Guide

Tiandy

Tiandy 5820B Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.