Lumel PD12 User manual

USB/RS-232
INTERFACE CONVERTER
PD12 TYPE
USERS MANUAL


!
1. APPLICATION ................................................................................ 5
2. CONVERTER SET......................................................................... 5
3. CONVERTER INSTALLATION ...................................................... 6
3.1. Converter mounting ............................................................... 6
3.2. Des ription of onverter leads .............................................. 6
3.3. Installation of the COM port for Windows ............................. 7
3.4. Installation of COM port ontrollers on the omputer ........... 7
3.5. Example of Lumel-Heat and Lumel-Energy onfiguration
to o-operate with PD12 ........................................................ 8
4. NOTES ........................................................................................... 8
5. TECHNICAL DATA ......................................................................... 9
6. ORDERING CODES ................................................................... 10
7. MAINTENANCE AND WARRANTY ............................................. 11
CONTENTS
USB/RS-232 INTERFACE CONVERTER
PD12 TYPE
USERS MANUAL

"

#
1. APPLICATION
At present, more and more PC omputers operating in industrial omputer-based
systems are equipped only with a USB (Universal Serial Bus) serial interfa e. This
interfa e serves to ommuni ate with other omputers and devi es in the frame-
work of the USB network.
The PD12 onverter is a devi e enabling, in a very easy way, to reate the
onne tion between the USB and the RS-232 port , ensuring simultaneously betwe-
en them the galvani separation. The USB interfa e is destined to ommuni ate with
the omputer, however the RS-232 interfa e is destined to ommuni ate with
devi es in the obje t side.
The maximal baud rate is 921.6 kb/s.
The onverter does not interfere in the stru ture of transmitted data and is ompa-
tible with a lot of industrial ommuni ation proto ols, i.e. MODBUS RTU, MODBUS
ASCII, LUMBUS, and the like.
A programmed ontroller of the network serial port for the master system omputer
is added to the set. It allows supervising programs to ex hange data with industrial
obje ts via the PD12 onverter.
2. CONVERTER SET
The PD12 onverter set in ludes:
- PD12 onverter 1 p
- Users manual 1 p
- Warranty ard 1 p
- Diskette with VCP drivers 1 p
- Plate with ontrollers 1 p
When unpacking the converter, please check the delivery completeness and
whether the type and version code on the data plate correspond to the order.

$
3. CONVERTER INSTALLATION
3.1. Converter mounting
The onverter is a portable devi e supplied from z USB bus.
The PD12 onverter onne tion way is presented on the fig.1.
TxD RxD
RS-232
USB
RS-232 USB
To RS-232 To USB
TxD RxD
RS-232
42,7
USB
80,2
Fig.1 Overall dimensions of the PD12 converter
Fig. 2 eads of the PD12 converter
3.2. Description o converter leads
Markings of individual leads are shown on the fig. 2
External signals must be onne ted a . to tables 1 and 2, in whi h the assignment
of individual PD12 onverter leads are des ribed.
There are two diodes on the frontal plate :
Green (RxD) - signals the re eption of data via RS-232
Yellow (TxD) - signals the transmission of data via RS-232

%
USB interface leads Table 2
1 +5 V d. .
2 -Data
3 +Data
4 GND
USB signalsNo of USB pin ( type B)
RS-232 interface leads Table 1
2 RxD
3TxD
5 GND
7RTS
8CTS
RS-232 signalsDB9 RS-232 pin No
3.3. Installation o the COM port or Windows
The PD12 onverter unfair advantage of FTDIBUS and FTDIPORT driver ontrollers,
li ensed by Future Te hnology Devi es International Ltd.
This software reates a new devi e of the Universal Serial Bus system - USB -
RS232 con erter of PD12 type and onne ted Port (Com) to it - PD12 USB-RS232
Port(COM).
The installation of a ontroller in the Windows system auses the addition of the
next COM serial port to the list of ports servi ed by the operating system.
3.4. Installation o COM port controllers on the computer
After onne ting the onverter to the USB port, the operating system will inform us
about the o urren e of a new devi e by means of the system. The reator, finding
the new hardware of the Universal Serial Bus will be started automati ally.
One must pro eed a . to the reator suggestions, hoosing the Installation from
the indi ated lo ation and giving the a ess path to ontrollers being on the plate
added to the onverter.
On the plate with ontrollers, there are ontrollers for following operating systems:
Windows 98, 98SE, 2000, ME and XP. When installing ontrollers, information that
the software has not been submitted to tests in a ordan e with the Windows
system

&
an o ur. One must ignore su h information and ontinue the further installation.
After losing the reator, the system dete ts immediately the next devi e - USB
Serial Port.
The reator to find a new hardware will be started again.
After the su essful installation termination, the system will inform about the instal-
lation of a new hardware.
Two new devi es will appear in the devi e Manager - The USB-RS232 con erter of
PD12 type and PD12 USB-RS232 Port (COM).
3.5. Example o Lumel Heat and Lumel 3000
con iguration to co-operate wit PD12
Lumel-Heat and Lumel 3000 systems ommuni ate with industrial devi es by means
of COM serial ports.
After installing additional COM serial ports, one an refer to them in systems of
LUMEL series. Then, one must introdu e in new and existing appli ations or system
onfigurations, or hange supervision an ellations to added ommuni ation ports.
Lumel-Energy programs in older version than 2.5, servi e maximally 4 serial ports
and in su h systems, serial ports must be installed as COM1...4).
4. NOTES
The PD12 onverter an work with a maximal baud rate up to 921.6 kb/s on lines to
15 m length.
In the en ironment with unknown interference le el it is recommended
to obser e following principles:
lConne tions of ommuni ation interfa e ir uits must be ondu t
individually by twisted wires in a shield.
lApply the general prin iple that wires (group of wires) leading different
signals should be led in the possible farthest distan e between them
(not less than 50 m) and the rossing of su h group of wires should
be made at right angle.
!

'
5. TECHNICAL DATA
USB:
- ompatible with USB 1.0, 1.1, 2.0
- onne tor USB type B
RS-232:
- Signals TxD, RxD, RTS, CTS, GND
- Conne tor DB9 male
Transmission data:
- baud rate [kbit/s] 1.2... 921.6
- ontrol of transmission flow RTS/CTS, XON/XOFF, WITHOUT
CONTROL
- parity none, Even, Odd, Spa e, Mark
- data bits 5, 6, 7, 8
- stop bits 1, 1.5, 2
- ontrollers Windows 98/98SE/Me, 2000/XP
Con erter power consumption 30 mA, at 5 V d. .
Rated operation conditions:
- supply voltage 5 V d. ., from the USB port
- ambient temperature 0... 55°C
- relative humidity < 85%
- external magneti field < 400 A/m
- working position any
Storage and transport conditions:
- ambient temperature 0...70°C
- relative humidity < 85%
- admissible sinusoidal vibrations:
- frequen y 10...150 Hz
- displa ement amplitude £ 0.35 mm
Ensured protection grades:
- from the housing side IP 40
- from the terminal side IP 20
Dimensions 65 x 43 x 24 mm
Weight 0.1 kg
Housing portable

Electromagnetic compatibility:
- immunity EN 61000-6-2
- emission EN 61000-6-4
Safety requirements acc. EN 61010-1:
- installation ategory III
- pollution grade 2
Maximal working oltage in relation to earth:
- for supplying ir uits 50 V
- for other ir uits 50 V
6. ORDERING CODES
CONVERTER PD12 X X X
Gal anic insulation:
with insulation ........................................................... 1
without insulation ...................................................... 2
Kind of ersion:
atalog ............................................................................... 0
ustom-made* ................................................................... X
Acceptance tests:
without extra requirements ......................................................... 0
with an extra quality inspe tion ertifi ate ................................. 1
other requirements* ....................................................................X
* The version ode is established by the manufa turer
PD12 version odes Table 4
Example of ordering:
PD12 1 0 1 ode means:
PD12 - USB-RS485 interfa e onverter:
1- with galvani insulation
0- atalog version
1- with an extra quality inspe tion ertifi ate

7. MAINTENANCE AND WARRANTY
The PD12 onverter does not require any periodi al maintenan e. In ase of some
in orre t operations:
1. After the dispatch date and within the period stated in the warranty card
One should return the instrument to the manufa turers Quality Inspe tion
Dept. If the instrument has been used in omplian e with the instru tions, the
manufa turer warrants to repair it free of harge. The disassembling of the
housing auses the an ellation of the granted warranty.
2. After the warranty period
One should send the instrument to repair it in an authorized servi e workshop.
Spare parts are available for the period of five years from the date of pur hase.
Our policy is one of continuous impro ement and we reser e the right
to make changes in design and specifications of any products as engi-
neering ad ances or necessity requires and re ise the abo e specifica-
tions without notice.

MEASUREMENT
CONTROL
RECORDING
Lubuskie Zak³ady Aparatów Elektrycznych LUMEL S.A.
ul. Sule howska 1, 65-022 Zielona Góra, Poland
Tel.: (48-68) 3295 100 (ex hange)
Fax: (48-68) 3295 101
e-mail:lumel@lumel. om.pl
http://www.lumel. om.pl
Export Department:
Tel.: (48-68) 3295 302 or 304
Fax: (48-68) 3254 091
e-mail: export@lumel. om.pl
)KCKIJ #
SALES PROGRAM
§ DIGITAL and BARGRAPH PANEL METERS
§ MEASURING TRANSDUCERS
§ ANALOG PANEL METERS (DIN INSTRUMENTS)
§ ANALOG and DIGITAL CLAMP-ON METERS
§ INDUSTRIAL and HOUSEHOLD CONTROLLERS
§ CHART AND PAPERLESS RECORDERS
§ POWER CONTROL UNITS and INVERTERS
§ AUTOMOTIVE DASHBOARD INDICATORS
§ ACCESSORIES FOR MEASURING INSTRUMENTS
§ MEASURING SYSTEMS (ENERGY, HEAT, CONTROL)
§ CUSTOM-MADE PRODUCTS
WE ALSO OFFER OUR SERVICES IN THE PRODUCTION OF:
§ ALUMINIUM ALLOY PRESSURE CASTINGS
§ PRECISION ENGINEERING AND THERMOPLASTICS PARTS
QUALITY PROCEDURES:
A ording to ISO 9001 and ISO 14001 international requirements.
All our instruments have CE mark .
For more information, please write to or phone our Export Department
Table of contents
Other Lumel Media Converter manuals
Popular Media Converter manuals by other brands

Siko
Siko SG32 quick start guide

Lika
Lika DRAW WIRE SF0M1 Series manual

Lika
Lika Posicontrol IF55 LIN CB Series Mounting instructions

DirectOut Technologies
DirectOut Technologies ANDIAMO 2.AD Hardware guide

Cross Technologies
Cross Technologies 2017-93 instruction manual

PCS Electronics
PCS Electronics CyberMax8000 Plus manual