manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lutron Electronics
  6. •
  7. Security System
  8. •
  9. Lutron Electronics radioRA RA-QS-SEC-1 User manual

Lutron Electronics radioRA RA-QS-SEC-1 User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

RA-QS-SEC-1 Security Package
Package Contents:
(3) 600 W Dimmers
(1) Multi-Function Entry Master Control (1) Car Visor Control Transmitter
(1) RF Signal Repeater
All components must be located within
30 feet (9 m)–in any direction–of the RF
Signal Repeater
30 ft. (9 m) radius
Typical Range up
to 150 feet (46 m)
MFE
Visor Control
Transmitter
(in vehicle)
Repeater
Component Layout
Place RF Signal Repeater in a central location
1
3
2
Initial Programming
This is a quick start system, which is pre-configured to fit typical
situations. If a device is added, removed, or returned to factory
default settings, additional programming will be required using
standand RadioRA programming methods.
ALL OFF Button
Turns all lights off
ALL ON Button
Turns all lights on
to full brightness
Security
Dimmer &
turn on to full
brightness
Flash Dimmer
Home - all lights turn on to 90% ROOM Monitoring
Dimmer
Dimmer
Dimmer
1
3
2
3
1
1
2
Away - Dimmer to 50%, all others off
Garage Door 1
Multi-Function Entry Master Control
Visor Control
Transmitter
Suggestion: Dimmer should control an exterior
light as it will flash during Security events and
stay on when the Away scene is activated.
1
Worldwide Technical and Sales Assistance
If you have questions concerning the installation or operation of this
product, call the Lutron Technical Support Center. Please provide
exact model number when calling.
+1.800.523.9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1.610.282.3800
Fax +1.610.282.3090
Visit us on the Web at www.lutron.com/radiora
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036
Made and printed in the U.S.A. P/N 044-106 3/06 Rev. A
This product may be covered under one or more of the following U.S. patents: 4,835,343;
5,248,919; 5,399,940; 5,637,930; 5,736,965; 5,798,581; 5,838,226; 5,848,054; 5,905,442;
5,982,103; 6,687,487; DES353,798; DES389,805; DES404,013; and corresponding foreign
patents. U.S. and foreign patents pending. Lutron, RadioRA and the Sunburst logo are registered
trademarks of Lutron Electronics Co., Inc.
© 2006 Lutron Electronics Co., Inc.
FCC Information
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on. The user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Changes or modifications not expressly approved by Lutron Electronics Co. could void the user's
authority to operate this equipment. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Dimmer Operation
1
Visor Control Transmitter
Operation
Buttons
Remotely activate
buttons on the Multi-
Function Entry Master
Control
Service Switch
• When replacing light
bulbs, pull out to “OFF”
position to disconnect
power
Status Indicators (LEDs)
• Glow brightly when light is on
• Glow softly when light is off
• Show light level
Dimming Rocker
• Press top to brighten
• Press bottom to dim
Temporary Dimmer Label
• Indicates Master Control
button programming
Tapswitch
• Tap on, tap off
• Tap twice quickly - lights
adjust rapidly to full
• Press and hold to activate
10-second fade to off
Contact Closure
Output Buttons
Controls garage doors
Security Buttons
When held, or when a
Security System contact
closure input is detected,
turns assigned lights on to
Full Bright (Full) or Flashes
assigned lights (Flash)
Learn Button
Used to assign MFE
buttons to Visor Control
Transmitters
Status Indicators (LEDs)
Glow when light is on
SCENE Buttons
Turn preset lighting scenes
on and off
ROOM Buttons
Monitor and turn individual
room lights on and off
ALL ON Button
Turns all lights on
to full brightness
ALL OFF Button
Turns all lights off
Multi-Function Entry Master Control (MFE) Operation