Step 2: Unplug the 3-position screw terminal (black) from
Step 3:
Step 4: Insert the negative wire from your 24 Vac/dc, 50/60 Hz
circuit to the terminal marked ~/- on the screw terminal
and tighten down the screw.
Step 5: Insert the ground wire from your 24 Vac/dc, 50/60 Hz
on the
circuit to ground (far left terminal) marked
screw terminal and tighten down the screw.
Step 6: Plug the 3-position screw terminal connector back
into the Power port on the JENEsys Edge 414.
Step 7: Temporarily change your computer’s network settings so your IP address is in
the range: 192.168.1.1 to 192.168.1.254 (without using the JENEsys Edge 414’s
default address as described in Step 8). Make note of your computer’s current
network settings.
Step 8: With ProBuilder (Workbench) 4.10.1/4.9.1/4.7.110 installed on your computer,
make a Platform connection to the JENEsys Edge 414 using the factory default IP
address (192.168.1.12n, where the last numeral (n) matches the last numeral in
the JENEsys Edge 414’s Host ID number), platform daemon port (3011), and
the following credentials:
Username: tridium
Password: niagara
Step 9: Refer to the GETTING STARTED WITH NIAGARA 4 GUIDE and JENESYS EDGE 414
USER GUIDE for detailed instructions on how to configure it using Niagara 4.
Package Contents of JENE-EG414
Estimated completion time: 5-10 minutes
(1) JENEsys Edge 414 (JENE-EG414)
This JENEsys Edge 414 Installation Guide
(1) JENEsys Edge 414 Wiring Installation Guide
(3) 6-Position Terminal Connectors (2 black & 1 blue)
(5) 3-Position Terminal Connectors (2 black, 1 gray & 2 blue)
Preparing to Install
Decide on the location/placement of your JENEsys Edge 414, ensuring its position is
upward/vertical. You can use wall mounting screws (not provided) to mount the device in an
open space or mount on a 35mm wide DIN rail utilizing the molded DIN rail slot
located on the base of the device. Make sure the selected location is:
Not in direct sunlight or near a heater or heating vent
Not cluttered/crowded and sufficient clearance is available above and below the
JENEsys Edge 414 for proper ventilation and room for cables and wiring
Well-ventilated (especially if enclosed in a cabinet)
This device has been loaded with the bare minimum Niagara 4.2.36 software and requires
the latest Onyxx Driver package to commission and update the controller's firmware.
Download the latest N4 version of the required Onyxx Driver package at:
resources.lynxspring.com.
Physical Mounting to a DIN Rail
For UL safety compliance this Lynxspring product shall be mounted inside enclosures with no
openings below the device and if non-metallic, a flammability rating of at least HB.
Step 1: Pull out the DIN rail clip and push down and in to force the DIN rail clip to snap
over the other edge of the DIN rail.
Step 2: Pull out the DIN rail clip and push down and in to force the DIN rail clip to snap
over the other edge of the DIN rail.
Step 3: To keep the JENEsys Edge 414 from sliding on the DIN rail, secure it with clips
provided by the DIN rail vendor, or place a screw in one of the mounting tabs in
the base of the JENEsys Edge 414.
Note 1: Up to three Onyxx XM 34IOs can be connected. See section:
CONNECTING ONYXX NETWORKS TO JENESYS EDGE 414 for details.
Note 2: To remove the device(s) from a DIN rail, insert a screwdriver in center plastic
locking tab and pull downwards, then lift the unit outwards.
Connecting to the JENEsys Edge 414
A 10/100-Mbit Ethernet connection is available on the JENEsys Edge 414. The
RJ-45 port has two LED s. When the device is connected to a network, the blue LINK LED is lit
and the blue ACTIVI TY LED flashes when activity occurs.
Step 1: Connect one end of the Ethernet cable to your
JENEsys Edge 414
’s Primary RJ-45 port and the
other end to the internet port on your
computer.
the Power port on the JENEsys Edge 414.
Insert the positive wire from your 24 Vac/dc, 50/60 Hz
circuit to the termi
nal marked ~/+ on the screw terminal
and tighte
n down the screw.
RECOMMENDED RS-485 CABLE SPECIFICATION
Max Cable Length 4,000 feet
Min loaded driver output signal level ± 1.5v
Driver load impedance (Ohms) 54
Receiver input voltage range -7v to + 12v
Receiver input resistance (Ohms) ≥12k
C
onnecting RS-485 Networks to JENEsys Edge 414
The RS-485 ports use a 3-position, screw terminal connector. The screw
terminals (from left-to-right) are shield, negative (-), and positive (+). The transmit
(Tx) and receive (Rx) LEDs located on the JENEsys Edge 414 cover will flash when there
is network activity detected.
Step 1: Unplug 3-position screw terminal connector
from either RS-485 port on the device.
Step 2: Insert positive wire from your RS-485 network
to positive terminal (far right terminal) on the
3-position, screw terminal connector and
tighten down the screw.
Step 3: Insert negative wire from your BACnet network to
negative terminal (center terminal) on the 3-position, screw
terminal connector and tighten down the screw. Please
refer to the JENESYS EDGE 414 WIRING INSTALLATION GUIDE for
further wiring instructions and cautions.
Step 4: Lynxspring recommends installing a 120-ohm end-of-line resistor on the
positive (+) and negative (-) terminals.
Step 5: Plug 3-position screw terminal connector back into the RS-485 port.
RS-485 Network
JENEsys Edge® 414
INSTALLATION GUIDE
Ma
de in USA
Ethernet Cable
Connection from
device to computer
24 Vac/dc Power
Specifications
PLATFORM
Operating System Niagara 4.10.1/4.9.1/4.7.110
Processor 1 GHz AM335x ARM Cortex A8
Memory 512 MB DDR3L 800 MHz, 4 GB 8-bit Embedded MMC on-
board Flash
Real-Time Clock (RTC) Battery-powered clock included to store description/setup values
including: year, month, date, hours, minutes and seconds
COMMUNICATION PORTS
2 Ethernet Ports 10/100 Mbps (RJ-45 Connector)
2 RS-485 Ports RS-485 serial port with 3-screw connector
Mini B-USB USB Client Connector utilizes 5-pin Mini-B USB cable
Micro USB Serial shell access
Onyxx Network 3-wire (LxH LxL SHLD) high-speed differential serial signal
INPUTS & OUTPUTS
6 Universal Inputs Type-3 10 K ohm thermistors; resistance 0-100 K ohms;
0-10Vdc; 0-20 mA using a 499-ohm resistor; pulse input: up
to 500 Hz; 12 bit A/D resolution
4 Digital Outputs Form A contacts, 24 V at 0.5 A
4 Analog Outputs 0-10 Vdc
Connector Screw Size 3/32” slotted
Supported Wire Size 28-16 AWG
Housing UL94V-0
POWER
Power Input External 24 Vac/dc +10%/-10%, 50/60 Hz, minimum 18 VA/
device
CHASSIS
Construction Base: Plastic, DIN rail or screw mount Cover: Plastic
Cooling Internal air convection
Dimensions 3.46” (8.79 cm) width x 4.25” (10.8 cm) length x
2.125” (5.4 cm) depth
Mounting Flat panel and 35 mm DIN rail mounting options standard
ENVIRONMENT
Operating Temperature Range 0 – 60 °C (32 –140 °F)
Storage Temperature Range 0 – 70 °C (32 –158 °F)
Relative Humidity Range 5 – 95% RH, non-condensing
CERTIFICATIONS
Compliance Pending: FCC 47CFR Parts 15B and 18, EN 55022, EN 55011,
ICES-003, RoHS, UL 916, CSA C22.2 No. 205-17, EN 61010-1: 2010,
IEC 61010-1, 3rd edition
Revised 1/28/2021 | JENE-EG414-IG-V1.0
Make sure the JENEsys Edge 414 is fully up and running. The power LED should turn
on and the heartbeat LED should be flashing.
Make sure the Ethernet cable is connected firmly to the primary Ethernet port on the
JENEsys Edge 414. The LEDs on the Ethernet port will indicate if the JENEsys Edge 414 is
connected to the network. The blue LINK LED will indicate the JENEsys Edge 414 is
connected to a network and additional blue ACTIVITY LEDs will indicate the JENEsys
Edge 414 is transmitting and receiving on the network.
If you are connecting directly from your computer to the JENEsys Edge 414 ensure your
computer’s network settings are set so that your computer’s IP address is anything
other than the device, in the same subnet.
Close and re-open the browser to make sure that the browser did not cache the
previous page.
Statement of Conditions
In the interest of improving internal design, operational function, and/or operability,
Lynxspring reserves the right to make changes to the product described in this
document without notice. Lynxspring does not assume any liability that may occur due to
the use or application of the product(s) or circuit layout(s) described herein.
Technical Support
Thank you for selecting Lynxspring products. Please contact our Support Team with any
questions about installing or setting up your new JENEsys Edge 414 (JENE-EG414).
[email protected] | toll free: 877-649-5969
Proper Disposal
This product contains a lithium battery.
The U.S. Environmental Protection Agency (EPA) does not regulate the disposal of
batteries in small quantities; large quantities are regulated under the Universal rules of
Hazardous Waste regulations (40 CFR PART 273). Lithium batteries are not currently
being collected by manufacturers for recycling. While there are no federal regulations for
disposal of lithium batteries, individual states can establish their own guidelines for
battery disposal and should be contacted for any local disposal guidelines.
The shipment of live or discharged lithium batteries is governed by the Department of
Transportation (DOT) in their Code of Federal Regulations (49 CFR), paragraph
173.185(j). Remember that before any type of disposal the batteries should be
discharged completely. Tape the contacts with electrical tape and package so as to
prevent contacts accidentally coming together at any time.
©2021 Lynxspring, Inc. All Rights Reserved.
NOTICE: All information contained herein is, and remains the property of Lynxspring, Incorporated.
The intellectual and technical concepts contained herein are proprietary to Lynxspring, Incorporated and may
be covered by U.S. and Foreign Patents, patents in process, and are protected by trade secret or copyright
law. Dissemination of this information or reproduction of this material is strictly forbidden unless prior written
permission is obtained from Lynxspring Incorporated.
Lynxspring®, JENEsys®, JENEsys Edge®, Onyxx® and Helixx® are registered trademarks of Lynxspring, Inc.
Niagara Framework® is a registered trademark of Tridium, Inc.
The information and/or specifications published here are current as of the date of publication of this
document. Lynxspring, Inc. reserves the right to change or modify specifications without prior notice. The latest
product specifications can be found by contacting our corporate headquarters in Lee’s Summit, Missouri.
Products or features contained herein are covered by one or more United States or foreign patents.
Other brand and product names are trademarks or registered trademarks of their respective holders.
This document may be copied by parties who are authorized to distribute Lynxspring products in connection
with distribution of those products, subject to the contracts that authorize such distribution. It may not
otherwise, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic
medium or machine-readable form without prior written consent from Lynxspring, Inc. Complete
Confidentiality, Trademark, Copyright and Patent notifications can be found at:
http://resources.lynxspring.com.
Connecting Onyxx Networks (Onyxx XM 34IO to JENEsys Edge 414)
Step 1: Unplug 3-position screw terminal connector (gray) from port marked LxH, LxL and
SHLD on the JENEsys Edge 414.
Step 2: Insert a wire between LxH terminal (far left terminal) on the 3-position screw
terminal connector of each device and tighten down the screw.
Step 3: Insert a wire between LxL terminal (center terminal) on the 3-position screw
terminal connector of each device and tighten down the screw.
Step 4: Insert the shield wire between SHLD terminal (far right terminal) on the
3-position screw terminal to connect of each device and tighten the screw.
Step 5: If the Onyxx XM 34IO is located at the end of the network, Lynxspring recommends
installing a 120-ohm end-of-line resistor on the LxH and LxL terminals.
Step 6: Plug 3-position screw terminal connector back into the port marked LxH, LxL and
SHLD on the JENEsys Edge 414 and Onyxx XM 34IO as needed.
Troubleshooting
If you are unable to make a platform connection to the JENEsys Edge 414:
Corporate Headquarters
2900 NE Independence Ave
Lees Summit, MO 64064
P: 816-347-3500 | F: 816-347-0780
This symbol was placed in accordance with the European Union Directive
2002/96 on the Waste Electric and Electronic Equipment (the WEEE Directive). If
disposed of within the European Union, this product should be treated and
recycled in accordance with the laws of your jurisdiction implementing the
WEEE Directive.

Other Lynxspring Controllers manuals

Lynxspring JENEsys Edge 534 User manual

Lynxspring

Lynxspring JENEsys Edge 534 User manual

Lynxspring JENEsys Edge 534 User manual

Lynxspring

Lynxspring JENEsys Edge 534 User manual

Lynxspring BW437-FCU-LX User manual

Lynxspring

Lynxspring BW437-FCU-LX User manual

Lynxspring onyxx LX BW437-RTU-LX User manual

Lynxspring

Lynxspring onyxx LX BW437-RTU-LX User manual

Lynxspring JENEsys Edge 100 User manual

Lynxspring

Lynxspring JENEsys Edge 100 User manual

Lynxspring onyxx LX BZ122-LX User manual

Lynxspring

Lynxspring onyxx LX BZ122-LX User manual

Lynxspring ONYXX LX BZ424-LX User manual

Lynxspring

Lynxspring ONYXX LX BZ424-LX User manual

Lynxspring JENEsys Edge 534 User manual

Lynxspring

Lynxspring JENEsys Edge 534 User manual

Lynxspring JENEsysONE JO-PC1 Installation instructions manual

Lynxspring

Lynxspring JENEsysONE JO-PC1 Installation instructions manual

Popular Controllers manuals by other brands

Lightware MX-FR9 user manual

Lightware

Lightware MX-FR9 user manual

Starfire SF -2100 - c manual

Starfire

Starfire SF -2100 - c manual

Linak ACTUATOR LA36 Connection diagram

Linak

Linak ACTUATOR LA36 Connection diagram

Cooper Lighting WaveLinx Outdoor installation instructions

Cooper Lighting

Cooper Lighting WaveLinx Outdoor installation instructions

Technische Alternative UVR610 installation instructions

Technische Alternative

Technische Alternative UVR610 installation instructions

ITC 230-00041 Install instructions

ITC

ITC 230-00041 Install instructions

Daikin BRC1H61W Operating handbook

Daikin

Daikin BRC1H61W Operating handbook

Intiel VENTOCONTROL user manual

Intiel

Intiel VENTOCONTROL user manual

Brinkmann FKO PROFIBUS Additional Operating Manual

Brinkmann

Brinkmann FKO PROFIBUS Additional Operating Manual

Samsung SCC-1000 user guide

Samsung

Samsung SCC-1000 user guide

Solinst 9100 STS Gold Replacement instructions

Solinst

Solinst 9100 STS Gold Replacement instructions

Mitsubishi Melsec FX-4AD user guide

Mitsubishi

Mitsubishi Melsec FX-4AD user guide

Omron G9SP-N20S Operation manuals

Omron

Omron G9SP-N20S Operation manuals

RDS PS 8000 Operation

RDS

RDS PS 8000 Operation

ABB TZIDC-110 Short manual

ABB

ABB TZIDC-110 Short manual

AGPtek HA0278 user manual

AGPtek

AGPtek HA0278 user manual

Watlow CLS200 user guide

Watlow

Watlow CLS200 user guide

TC Electronic TC ICON Series user manual

TC Electronic

TC Electronic TC ICON Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.