3www.m-locks.com
E-Pass V01 EN
1 IMPORTANT INSTRUCTIONS
• Before mounting the lock, please read the instructions for use carefully.
• Ensure that you only program the lock when the door is open.
• After changing the code, always try the code several times with the safedoor open.
• Only after several positive function tests (opening / closing) the door may be closed.
• Each key entry is confirmed by an audible tone and visual signal. These signals are not referred to in
the description that follows.
• Acoustic signals are always accompanied by the same optical signals.
• You have a maximum of 10 seconds for each key entry. If you do not make an entry via the keypad
during this period of 10 seconds, the entry procedure will automatically abort. You must then start
again from the beginning.
• After entering a valid code, you will hear two audible tones. An invalid entry will trigger a long tone.
• After entering an invalid code at the first attempt; wait 20 seconds before entering the code again.
• If the code is entered incorrectly on four consecutive occasions the keypad and the lock will be
disabled for 5 minutes. During this period, the LED will flash every 10 seconds and you will hear a
long tone when attempting to make an entry. Entering an incorrect code on two further occasions
after the keypad has been re-enabled, will trigger a new keypad lock-out period of 5 minutes. After
entering a valid code you have four new occasions to enter the code and open the lock.
!Caution!
• The lock has been designed for use in a temperature range from +10˚C to +50˚C and a non-
condensing humidity range from 30% to 80%.
• It may only be cleaned with a moist cloth (do not use aggressive cleaning agents).
• The lock may only be installed by qualified fitters.
• The lock may not be lubricated.
• Never open the lock housing. If it is necessary to disassemble the hardware, only do so in
accordance with the technical instructions. If you fail to do so, the lock may no longer function
properly and you will forfeit your right to warranty.
2CHARACTERISTICS
In the factory setting, the E-Pass can be opened either after entering 1-2-3-4 (hotel version) or after
entering 1-2-3-4-5-6 (vault version) depending on the version. The blocking element is an electro-
magnet. After a valid code has been entered, the electronics are released for 4 seconds and the E-Pass
can be unlocked by turning the handle. If the handle is turned back, the lock locks automatically. The
E-Pass is supplied with Right Hand opening(RH). With minimal effort it can be changed to Left Hand
opening(LH).The HU-versions are mounted vertical as shown, The HL-versions are mounted horizontal