manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system 61F User manual

M-system 61F User manual

Other M-system Control Unit manuals

M-system R7M-SV4-R User manual

M-system

M-system R7M-SV4-R User manual

M-system R3-NEIP1 User manual

M-system

M-system R3-NEIP1 User manual

M-system R7HL-DAC16C User manual

M-system

M-system R7HL-DAC16C User manual

M-system R7G4HH-A-YVF4 User manual

M-system

M-system R7G4HH-A-YVF4 User manual

M-system R1M-A1 User manual

M-system

M-system R1M-A1 User manual

M-system R7M-EC8C User manual

M-system

M-system R7M-EC8C User manual

M-system R3-PD16 User manual

M-system

M-system R3-PD16 User manual

M-system M6NPS1 User manual

M-system

M-system M6NPS1 User manual

M-system R8-DCM16ALK User manual

M-system

M-system R8-DCM16ALK User manual

M-system R7M-DC16A User manual

M-system

M-system R7M-DC16A User manual

M-system R7C-TS4 User manual

M-system

M-system R7C-TS4 User manual

M-system EtherCAT R30GECT1 User manual

M-system

M-system EtherCAT R30GECT1 User manual

M-system R7C-EC8C User manual

M-system

M-system R7C-EC8C User manual

M-system R30TS4 User manual

M-system

M-system R30TS4 User manual

M-system R7M-EC16B User manual

M-system

M-system R7M-EC16B User manual

M-system R3-NP1 User manual

M-system

M-system R3-NP1 User manual

M-system 61A User manual

M-system

M-system 61A User manual

M-system M8CD1 User manual

M-system

M-system M8CD1 User manual

M-system R7L-EC8A User manual

M-system

M-system R7L-EC8A User manual

M-system R7C-DC16A User manual

M-system

M-system R7C-DC16A User manual

M-system R3Y-DS8N User manual

M-system

M-system R3Y-DS8N User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R7HL-DC16B-R User manual

M-system

M-system R7HL-DC16B-R User manual

M-system R3-NC3 User manual

M-system

M-system R3-NC3 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

BEFORE USE
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Analog I/O module (body + base socket) ............................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
85 – 132V AC rating: 85 – 132V, 47 – 66 Hz, approx. 3VA
24V DC rating: 24V ±10%, approx. 4W, approx. 160mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply, input signal and output signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: MxBS2).
ANALOG I/O MODULE
(Fuji Electric T-Link use) MODEL 61F
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6635 Rev.2 P. 1 / 3
INSTRUCTION MANUAL
COMPONENT IDENTIFICATION
Body
Specifications
1
2
3
4
5
6
7
8
9
0

1
2
3
4
5
6
7
8
9
0

■FRONT PANEL CONFIGURATION
L RUN
PU-2x
STATION NO.
L ERR.
L I/O
L COM
PWR
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
X
1
X
10
D
E
C
B
A
NAME FUNCTIONS
AModular jack for
factory calibration
Used only for factory calibration.
BPower indicator
LED
MARKING (color) FUNCTIONS
PWR (green) ON: Powered.
OFF: No Power
CStation No. setting Selectable within 00 – 99. (factory set to: 00)
DStatus indicator
LED
MARKING (color) FUNCTIONS
L RUN (red) ON: Normal Communication
OFF: Communication Cutoff (Timeout Error)
L ERR. (red) ON: Communication Data Error
OFF: Normal Communication
L I/O (red) Blinking during normal I/O function
L COM (red)
Blinking during normal T-Link Communication
EEuro type connec-
tor terminal for
T-Link
For wiring to T-Link
61F
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6635 Rev.2 P. 2 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
50 (1.97) 103 (4.06)38 min.
(1.50)
12
(.47)
80 (3.15)
100 (3.94)
2–M3 SCREWS
■CONNECTION DIAGRAM
+
−
Shielded
Twisted-pair Cable
To Other
T-Link Devices
*Jumper Pin
T1
T2
SD
RT+
RT−
Terminating
Resistor
* When the unit is located at the end of transmission line via twisted-pair cable
(= no cross-wiring), short across the RT+ and RT– terminals with the jumper pin
(or wire) provided with the unit.
Remove the jumper pin for the one not located at the end.
Note: Use terminals T1, T2 and SD for cross-wiring.
Modular Jack
for Factory
Calibration
MODULAR JACK
I/O & POWER CONNECTOR
To
Installation
Base
WIRING INSTRUCTIONS
■EURO TYPE CONNECTOR TERMINAL (T-Link)
Applicable wire size: 0.2 to 2.5 mm2(AWG24 to 12)
Stripped length: 7 mm
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protectors for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
61F
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6635 Rev.2 P. 3 / 3