EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system R3Y-PA16 User manual

M-system R3Y-PA16 User manual

Other M-system Control Unit manuals

M-system R7M-EC8A/UL User manual

M-system

M-system R7M-EC8A/UL User manual

M-system R3-PD16B User manual

M-system

M-system R3-PD16B User manual

M-system R3-PA16 User manual

M-system

M-system R3-PA16 User manual

M-system R7D-MS4 User manual

M-system

M-system R7D-MS4 User manual

M-system R7ML-EC8A User manual

M-system

M-system R7ML-EC8A User manual

M-system R3-SV8C User manual

M-system

M-system R3-SV8C User manual

M-system R30BS User manual

M-system

M-system R30BS User manual

M-system R7D-EC8B User manual

M-system

M-system R7D-EC8B User manual

M-system R7ML-YV2-R User manual

M-system

M-system R7ML-YV2-R User manual

M-system R7M-SV4 User manual

M-system

M-system R7M-SV4 User manual

M-system R7M-DA16 User manual

M-system

M-system R7M-DA16 User manual

M-system R3-PT4 User manual

M-system

M-system R3-PT4 User manual

M-system R3-NC3 User manual

M-system

M-system R3-NC3 User manual

M-system R3-PD16 User manual

M-system

M-system R3-PD16 User manual

M-system R7G4HH-A-YVF4 User manual

M-system

M-system R7G4HH-A-YVF4 User manual

M-system R8-SVT8 User manual

M-system

M-system R8-SVT8 User manual

M-system R80ND2 User manual

M-system

M-system R80ND2 User manual

M-system R7D-EA8 User manual

M-system

M-system R7D-EA8 User manual

M-system R7L-DA16 User manual

M-system

M-system R7L-DA16 User manual

M-system R3Y-SV8 User manual

M-system

M-system R3Y-SV8 User manual

M-system R7C-EC8C User manual

M-system

M-system R7C-EC8C User manual

M-system R3-NM3 User manual

M-system

M-system R3-NM3 User manual

M-system R3-NL1 User manual

M-system

M-system R3-NL1 User manual

M-system R7M-EC8C User manual

M-system

M-system R7M-EC8C User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

R3Y-PA16
P. 1 / 2 EM-8962 Rev.1
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
the contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
Totalized pulse input module ..................................... (1)
■ MODEL NO.
Check that model No. described on the specification label is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated in
a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ HOT INSERTION/REMOVAL OF MODULES
Removing or replacing modules does not affect other modules
on the same backplane. It is possible to replace them without
removing the power supply. However, replacing multiple
modules at once may greatly change line voltage levels. We
recommend that you replace them one by one.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ventila-
tion.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data sheet.
INSTRUCTION MANUAL
MODEL R3Y-PA16
TOTALIZED PULSE INPUT MODULE
(Pi 16 points)
COMPONENT IDENTIFICATION
INSTALLATION
Use the Installation Base (model: R3-BSx).
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
B
20 A
20
B
1A
1
RUN LED
ERR LED Status Indicator LED
Input Connector
■FRONT VIEW
• Pin Assignment
■SIDE VIEW
SW3
ON
4
3
2
1Count
Reset
Set the Count Reset SW to OFF to start counting.
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with the excitation abnormality;
Green in normal operating conditions.
Input status indicator: Red LED; turns on with the inputs
supplied.
R3Y-PA16
P. 2 / 2 EM-8962 Rev.1
■ CONNECTION DIAGRAM
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■ DIMENSIONS mm (inch) ■ INPUT CONNECTOR (40-pin)
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
productwasoriginallypurchasedifsuchproducthasbeenusedundernormaloperatingconditionsandproperlymaintained,M-System'ssoleliability,andpurchaser'sexclusiveremedies,
under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To
submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
BUS A
BUS B*
BUS CONNECTOR
INTERNAL
POWER
■R3Y-PA16x/A■R3Y-PA16x
* DO NOT use the terminals No. 4A/4B and 3A/3B.
**For dual redundant communication.
20A / 20B
5A / 5B
4A / 4B
3A / 3B
Pi 1
Pi 16
2A / 2B
1A / 1B
7A / 7B
Pi 15
9A / 9B
Pi 14
11A / 11B
Pi 13
13A / 13B
Pi 12
15A / 15B
Pi 11
17A / 17B
Pi 10
19A / 19B
Pi 9
6A / 6B
Pi 8
8A / 8B
Pi 7
10A / 10B
Pi 6
12A / 12B
Pi 5
14A / 14B
Pi 4
16A / 16B
Pi 3
18A / 18B
Pi 2
**
Pi 1
Pi 16
Pi 15
Pi 14
Pi 13
Pi 12
Pi 11
Pi 10
Pi 9
Pi 8
Pi 7
Pi 6
Pi 5
Pi 4
Pi 3
Pi 2
COM(+)
20A / 20B
5A / 5B
4A / 4B
3A / 3B
2A / 2B
1A / 1B
7A / 7B
9A / 9B
11A / 11B
13A / 13B
15A / 15B
17A / 17B
19A / 19B
6A / 6B
8A / 8B
10A / 10B
12A / 12B
14A / 14B
16A / 16B
18A / 18B
PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT
1A 0V 1B 0V
2A 0V 2B 0V
3A +24V 3B +24V
4A +24V 4B +24V
5A Pi 16 5B Pi 16
6A Pi 8 6B Pi 8
7A Pi 15 7B Pi 15
8A Pi 7 8B Pi 7
9A Pi 14 9B Pi 14
10A Pi 6 10B Pi 6
11A Pi 13 11B Pi 13
12A Pi 5 12B Pi 5
13A Pi 12 13B Pi 12
14A Pi 4 14B Pi 4
15A Pi 11 15B Pi 11
16A Pi 3 16B Pi 3
17A Pi 10 17B Pi 10
18A Pi 2 18B Pi 2
19A Pi 9 19B Pi 9
20A Pi 1 20B Pi 1