manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system R3-PT4 User manual

M-system R3-PT4 User manual

Other M-system Control Unit manuals

M-system R3-PA8 User manual

M-system

M-system R3-PA8 User manual

M-system R3-SV4B User manual

M-system

M-system R3-SV4B User manual

M-system M6NPS2 User manual

M-system

M-system M6NPS2 User manual

M-system R7D-EA16 User manual

M-system

M-system R7D-EA16 User manual

M-system R7HL-DC8C User manual

M-system

M-system R7HL-DC8C User manual

M-system R3-AV4 User manual

M-system

M-system R3-AV4 User manual

M-system R3S-DC8 User manual

M-system

M-system R3S-DC8 User manual

M-system R7M-EA16 User manual

M-system

M-system R7M-EA16 User manual

M-system R3-NM1 User manual

M-system

M-system R3-NM1 User manual

M-system R7M-YS2 User manual

M-system

M-system R7M-YS2 User manual

M-system R7ML-DC16A User manual

M-system

M-system R7ML-DC16A User manual

M-system R7M-YV2 User manual

M-system

M-system R7M-YV2 User manual

M-system R7M-EC8A User manual

M-system

M-system R7M-EC8A User manual

M-system R7E-DC16B User manual

M-system

M-system R7E-DC16B User manual

M-system R7L-EC16A User manual

M-system

M-system R7L-EC16A User manual

M-system R7C-EC8B/UL User manual

M-system

M-system R7C-EC8B/UL User manual

M-system 10DY User manual

M-system

M-system 10DY User manual

M-system R3-AS4 User manual

M-system

M-system R3-AS4 User manual

M-system R7L-DA16-R User manual

M-system

M-system R7L-DA16-R User manual

M-system R7ML-YV2-R User manual

M-system

M-system R7ML-YV2-R User manual

M-system R3-PA4A User manual

M-system

M-system R3-PA4A User manual

M-system R80ND2 User manual

M-system

M-system R80ND2 User manual

M-system R7F4HD-DC32B User manual

M-system

M-system R7F4HD-DC32B User manual

M-system R7M-DC16A User manual

M-system

M-system R7M-DC16A User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

R3-PT4
P. 1 / 2 EM-8398 Rev.1
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
the contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
AC Voltage input module ........................................... (1)
■ MODEL NO.
Check that model No. described on the specification label is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
■ UNPLUGGING THE UNIT
• Before you remove the unit from its base or mount it, turn
off the power supply for safety.
INSTRUCTION MANUAL
MODEL R3-PT4
AC VOLTAGE INPUT MODULE
(true RMS sensing)
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ventila-
tion.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
COMPONENT IDENTIFICATION
•Conversion Rate: SW3
SW CONVERSION RATE
80 ms (*)60 ms 40 ms 20 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
(*) Factory setting
ON
8
7
6
5
4
3
2
1
SW1SW2
ON
8
7
6
5
4
3
2
1
SW3
ON
4
3
2
1
1
2
3
4
5
6
7
8
9
10
■FRONT VIEW ■SIDE VIEW
ERR LED
RUN LED
Conv.
Rate
Input 2 (SW1)
or
Input 4 (SW2)
Range
Input 1 (SW1)
or
Input 3 (SW2)
■SIDE DIP SW
•Input Range: SW1, SW2
INPUT 1 (SW1) INPUT 2 (SW1)
INPUT 3 (SW2) INPUT 4 (SW2) RANGE
12345678
OFF OFF OFF OFF OFF OFF OFF OFF 0 – 250V(*)
ON OFF OFF OFF ON OFF OFF OFF 0 – 50V
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with the input abnormality;
Green in normal operating conditions.
R3-PT4
P. 2 / 2 EM-8398 Rev.1
■ DIMENSIONS mm (inch)
■ CONNECTION DIAGRAM
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
productwasoriginallypurchasedifsuchproducthasbeenusedundernormaloperatingconditionsandproperlymaintained,M-System'ssoleliability,andpurchaser'sexclusiveremedies,
under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To
submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]
WIRING INSTRUCTIONS
■SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solderless
terminals with insulation sleeve do not fit. Applicable wire
size: 0.75 – 2 mm2
3.7 (.15) dia.
6 min.
(.24)
14.5 (.57) max.
7 max.
(.28)
3.5 (.14) max.
BUS CONNECTOR
INTERNAL
POWER
BUS A
BUS B*
*For dual redundant communication.
3
4
5
6
7
8
9
10
V
U
v
u
FUSE VT
LOAD
SOURCE
V
U
v
u
FUSE VT
LOAD
SOURCE
V
U
v
u
FUSE VT
LOAD
SOURCE
V
U
v
u
FUSE VT
LOAD
SOURCE
INPUT 1
INPUT 2
INPUT 3
INPUT 4
130 (5.12)
27.5 (1.08) 109 (4.29)
7.9 (.31)
POSITIONING
GUIDE
TERMINAL
COVER
10—M3.5
SCREW
1
2
3
4
5
6
7
8
9
10