R7CWTU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7814 Rev.3 P. 12 / 18
■ENERGY
Writing the following registers enables energy presetting. Set CC-Link Register Access in order to write in the energy and
fractions.
RGTR. ID PARAMETER UNIT
Circuit 1 Circuit 2
129 4129 EP Active energy, high tariff, incoming kWh/10
131 4131 EQ Reactive energy, high tariff, LAG kvarh/10
133 4133 ES Apparent energy, high tariff kVAh/10
135 4135 EP– Active energy, high tariff, outgoing kWh/10
137 4137 EQ– Reactive energy, high tariff, LEAD kvarh/10
139
141
4139
4141
EQ+LAG
EQ+LEAD
Reactive energy, high tariff, incoming, LAG
Reactive energy, high tariff, incoming, LEAD
kvarh/10
kvarh/10
143
145
4143
4145
EQ–LAG
EQ–LEAD
Reactive energy, high tariff, outgoing, LAG
Reactive energy, high tariff, outgoing, LEAD
kvarh/10
kvarh/10
147 4147 TIMER Energy count time, high tariff h/10
149
151
4149
4151
EQ+P
EQ–P
Reactive energy, high tariff, incoming
Reactive energy, high tariff, outgoing
kvarh/10
kvarh/10
153 4153 EPA Active energy, high tariff, (incoming – outgoing) kWh/10
155 4155 EQA Reactive energy, high tariff, (incoming + outgoing) kvarh/10
161 4161 L-EP Active energy, low tariff, incoming kWh/10
163 4163 L-EQ Reactive energy, low tariff, LAG kvarh/10
165 4165 L-ES Apparent energy, low tariff kVAh/10
167 4167 L-EP– Active energy, low tariff, outgoing kWh/10
169 4169 L-EQ– Reactive energy, low tariff, LEAD kvarh/10
171
173
4171
4173
L-EQ+LAG
L-EQ+LEAD
Reactive energy, low tariff, incoming, LAG
Reactive energy, low tariff, incoming, LEAD
kvarh/10
kvarh/10
175
177
4175
4177
L-EQ–LAG
L-EQ–LEAD
Reactive energy, low tariff, outgoing, LAG
Reactive energy, low tariff, outgoing, LEAD
kvarh/10
kvarh/10
179 4179 L-TIMER Energy count time, low tariff h/10
181
183
4181
4183
L-EQ+P
L-EQ–P
Reactive energy, low tariff, incoming
Reactive energy, low tariff, outgoing
kvarh/10
kvarh/10
185 4185 L-EPA Active energy, low tariff, (incoming – outgoing) kWh/10
187 4187 L-EQA Reactive energy, low tariff, (incoming + outgoing) kvarh/10
193 4193 EP_L Active energy fraction, high tariff, incoming kWh/(10×232)
195 4195 EQ_L Reactive energy fraction, high tariff, LAG kvarh/(10×232)
197 4197 ES_L Apparent energy fraction, high tariff kVAh/(10×232)
199 4199 EP–_L Active energy fraction, high tariff, outgoing kWh/(10×232)
201 4201 EQ–_L Reactive energy fraction, high tariff, LEAD kvarh/(10×232)
203
205
4203
4205
EQ+LAG_L
EQ+LEAD_L
Reactive energy fraction, high tariff, incoming, LAG
Reactive energy fraction, high tariff, incoming, LEAD
kvarh/(10×232)
kvarh/(10×232)
207
209
4207
4209
EQ–LAG_L
EQ–LEAD_L
Reactive energy fraction, high tariff, outgoing, LAG
Reactive energy fraction, high tariff, outgoing, LEAD
kvarh/(10×232)
kvarh/(10×232)
211 4211 TIMER_L Energy fraction count time, high tariff seconds/1 000
213
215
4213
4215
EQ+P_L
EQ–P_L
Reactive energy fraction, high tariff, incoming
Reactive energy fraction, high tariff, outgoing
kvarh/(10×232)
kvarh/(10×232)
217 4217 EPA_L Active energy fraction, high tariff, (incoming – outgoing) kWh/(10×232)
219 4219 EQA_L Reactive energy fraction, high tariff, (incoming + outgoing) kvarh/(10×232)
225 4225 L-EP_L Active energy fraction, low tariff, incoming kWh/(10×232)
227 4227 L-EQ_L Reactive energy fraction, low tariff, LAG kvarh/(10×232)
229 4229 L-ES_L Apparent energy fraction, low tariff kVAh/(10×232)
231 4231 L-EP–_L Active energy fraction, low tariff, outgoing kWh/(10×232)
233 4233 L-EQ–_L Reactive energy fraction, low tariff, LEAD kvarh/(10×232)
235
237
4235
4237
L-EQ+LAG_L
L-EQ+LEAD_L
Reactive energy fraction, low tariff, incoming, LAG
Reactive energy fraction, low tariff, incoming, LEAD
kvarh/(10×232)
kvarh/(10×232)
239
241
4239
4241
L-EQ–LAG_L
L-EQ–LEAD_L
Reactive energy fraction, low tariff, outgoing, LAG
Reactive energy fraction, low tariff, outgoing, LEAD
kvarh/(10×232)
kvarh/(10×232)
243 4243 L-TIMER_L Energy fraction count time, low tariff seconds/1 000
245
247
4245
4247
L-EQ+P_L
L-EQ–P_L
Reactive energy fraction, low tariff, incoming
Reactive energy fraction, low tariff, outgoing
kvarh/(10×232)
kvarh/(10×232)
249 4249 L-EPA_L Active energy fraction, low tariff, (incoming – outgoing) kWh/(10×232)
251 4251 L-EQA_L Reactive energy fraction, low tariff, (incoming + outgoing) kvarh/(10×232)