BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 35mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Specifications
Front Cover
(Connection diagram
behind)
■FRONT VIEW (with cover open)
Span Adj.
Zero Adj.
1
78
56
2
34
INSTALLATION
Use Standard Rack (model: 18BXx or 18KBXx).
TACHOGENERATOR CONVERTER MODEL 18TG
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1839 Rev.5 P. 1 / 3
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram behind the front cover.
■EXTERNAL DIMENSIONS unit: mm (inch)
110 (4.33 )
93 (3.66)
24 (.94)
7 (.28)
78 (3.07)32 (1.26)
8–M3.5
SCREW
7 (.28)
2–M3
SCREW
■CONNECTION DIAGRAM
INPUT
1
2
+
–
OUTPUT 2
POWER
OUTPUT 1
OUTPUT 2
5
6
CONNECTOR
■TERMINAL ASSIGNMENTS
12
34
78
56
18TG
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1839 Rev.5 P. 2 / 3
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 18BXx or 18KBXx). For the DC power source, be
sure that the ripple level is within 10% p-p.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT 1
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
5) No need of adjustments for the Output 2.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
18TG
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1839 Rev.5 P. 3 / 3

Other M-system Media Converter manuals

M-system M8XV2 User manual

M-system

M-system M8XV2 User manual

M-system 17MS User manual

M-system

M-system 17MS User manual

M-system M8CTC User manual

M-system

M-system M8CTC User manual

M-system 18KTS User manual

M-system

M-system 18KTS User manual

M-system M8BS-8U1-R User manual

M-system

M-system M8BS-8U1-R User manual

M-system M8MS1 User manual

M-system

M-system M8MS1 User manual

M-system M8BS-8E1A User manual

M-system

M-system M8BS-8E1A User manual

M-system 17TG User manual

M-system

M-system 17TG User manual

M-system Mini-M M2RR User manual

M-system

M-system Mini-M M2RR User manual

M-system M8XV3 User manual

M-system

M-system M8XV3 User manual

M-system 18KJM User manual

M-system

M-system 18KJM User manual

M-system M8BS-4U0 User manual

M-system

M-system M8BS-4U0 User manual

M-system M8XM2 User manual

M-system

M-system M8XM2 User manual

M-system M8YV1 User manual

M-system

M-system M8YV1 User manual

M-system JFR2 User manual

M-system

M-system JFR2 User manual

M-system 15MS User manual

M-system

M-system 15MS User manual

M-system 18VS User manual

M-system

M-system 18VS User manual

M-system 15RS User manual

M-system

M-system 15RS User manual

M-system JAPD User manual

M-system

M-system JAPD User manual

M-system M8BS-16U0 User manual

M-system

M-system M8BS-16U0 User manual

M-system M8AP User manual

M-system

M-system M8AP User manual

M-system JPR2 User manual

M-system

M-system JPR2 User manual

M-system 18TS User manual

M-system

M-system 18TS User manual

M-system M8XR2 User manual

M-system

M-system M8XR2 User manual

Popular Media Converter manuals by other brands

Merging Technologies Horus user manual

Merging Technologies

Merging Technologies Horus user manual

ADF Web HD67508-A1-232 user manual

ADF Web

ADF Web HD67508-A1-232 user manual

Okto Research dac8 Stereo owner's manual

Okto Research

Okto Research dac8 Stereo owner's manual

DeLOCK 91620 user manual

DeLOCK

DeLOCK 91620 user manual

MADRIX Nebula Technical Manual & Quick Start Guide

MADRIX

MADRIX Nebula Technical Manual & Quick Start Guide

Philips SWS2102W Specifications

Philips

Philips SWS2102W Specifications

HDFury Nano GX user manual

HDFury

HDFury Nano GX user manual

MRC 0001663 quick start guide

MRC

MRC 0001663 quick start guide

evertz 7700 Series manual

evertz

evertz 7700 Series manual

Linear LTC3537 quick start guide

Linear

Linear LTC3537 quick start guide

Actox ABCN50X user manual

Actox

Actox ABCN50X user manual

TR-Electronic CE-65 Series user manual

TR-Electronic

TR-Electronic CE-65 Series user manual

Argent OpenTracker user manual

Argent

Argent OpenTracker user manual

Gomax CV-105 user manual

Gomax

Gomax CV-105 user manual

Philips mcm3350 user manual

Philips

Philips mcm3350 user manual

Densei-Lambda ZWS150PAF Series instruction manual

Densei-Lambda

Densei-Lambda ZWS150PAF Series instruction manual

Polytron PSG 510-10 TAP user manual

Polytron

Polytron PSG 510-10 TAP user manual

Ground Zero GZWR 10M owner's manual

Ground Zero

Ground Zero GZWR 10M owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.