manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech PR2000 User manual

MadgeTech PR2000 User manual

PR2000
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: RISK OF FIRE OR EXPLOSION. DO NOT RECHARGE, FORCE OPEN, HEAT OR DISPOSE
OF IN FIRE.
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
PO Box 50 lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1148035-00 REV 10 2012.02.16
PR2000
Pressure Data Logger with LCD
Part Number PR2000
Pressure Sensor Semiconductor (strain guage)
Pressure Range
*See Table BelowPressure Resolution
Pressure Accuracy
Memory 262,143
Sampling Rate 2 seconds to 24 hours
Required Interface
Package
IFC200
Baud Rate 115,200
Typical Battery Type 6 Alkaline AA Batteries
Operating Environment -20°C to 60°C (-4°F to 140°F),
0%RH to 95%RH (non-condensing)
Material Black anodized aluminum and
303 stainless steel NPT process connection
Dimensions 5.1” x 4.8” x 1.78” (130mm x 122mm x 45mm)
Approvals CE
* PR2000 Pressure Range, Resolution and Accuracy
Range (PSI) 0-30 0-100 0-300 0-500 0-1000 0-5000
Resolution 2% FSR, 0.25% @ 25°C typical
Accuracy (PSI) 0.002 0.005 0.02 0.05 0.05 0.2
Product Information Card
Product Notes
The PR2000 is a pressure data logger with LCD display. The device features an IP rating
of 65, which means it is dust proof, and splash proof making it available to be used
outdoors. The convenient LCD provides access to the current pressure reading, as well as
minimum, maximum and average statistics. A trending graph is also displayed of the last
100 readings.
For additional information refer to your PR2000 manual and “Data Logger & Software
Operating Manual”.
Submergibility
The PR2000 is rated IP65, which means it is dust tight and can withstand water jets.
Backlight
The backlight uses a significant amount of battery life. Refer to the manual to configure the
auto shut-off when not in use.
Set Password
To password protect the device so that others cannot start, stop or reset the device;
- Click Identify Device and Read Status, then select the Device Detail Tab.
- Choose Set Password.
- Enter and confirm the password and click OK
Device Maintenance
Battery Replacement
Materials: 9/64” HEX Driver (Allen Key) and a Replacement Batteries (6 AA)
- Remove the back cover from the device by unscrewing the four screws.
- Remove the batteries from the compartment.
- Insert the new batteries as indicated by the diagram on the battery holder.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The PR2000 standard calibration is dependant upon the range.
Pricing:
Recalibration traceable to NIST $60.00
Recalibration $40.00
Additional Services:
As Found Data $15.00 per parameter/channel
Verification Point $15.00 per point
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
PR2000 Product Quick Reference Card
Installation Guide
Installing the Interface Cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
Installing the Software
Insert the Software CD in the CD-ROM Drive. If the autorun does not appear, locate the
drive on the computer and double click on Autorun.exe. Follow the instructions provided
in the wizard.
Connecting the Data Logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Operation
Starting the Data Logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded data onto
the PC.
Range (PSIA) 0-30 0-100 0-300 0-500 0-1000 0-5000
Range (PSIG) 0-30 0-100 0-300 0-500 - -
Calibration
Points (PSIA)
~14.7 and
27-30
~14.7 and
90-100
~14.7 and
270-300
~14.7 and
270-300
~14.7 and
450-500
~14.7 and
450-500

Other manuals for PR2000

3

Other MadgeTech Data Logger manuals

MadgeTech MadgeNET RFTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNET RFTemp2000A Specification sheet

MadgeTech UltraShock-5-EB User manual

MadgeTech

MadgeTech UltraShock-5-EB User manual

MadgeTech RTDTempX Series Specification sheet

MadgeTech

MadgeTech RTDTempX Series Specification sheet

MadgeTech Logicbus X Series Specification sheet

MadgeTech

MadgeTech Logicbus X Series Specification sheet

MadgeTech State101A Specification sheet

MadgeTech

MadgeTech State101A Specification sheet

MadgeTech Shock101 User manual

MadgeTech

MadgeTech Shock101 User manual

MadgeTech TEMP1000EX User manual

MadgeTech

MadgeTech TEMP1000EX User manual

MadgeTech PR1000 Specification sheet

MadgeTech

MadgeTech PR1000 Specification sheet

MadgeTech Level1000 Specification sheet

MadgeTech

MadgeTech Level1000 Specification sheet

MadgeTech MicroTemp100 Specification sheet

MadgeTech

MadgeTech MicroTemp100 Specification sheet

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech CurrentX Series Specification sheet

MadgeTech

MadgeTech CurrentX Series Specification sheet

MadgeTech Bridge120 Series User manual

MadgeTech

MadgeTech Bridge120 Series User manual

MadgeTech 902003-00 Specification sheet

MadgeTech

MadgeTech 902003-00 Specification sheet

MadgeTech Event101A Specification sheet

MadgeTech

MadgeTech Event101A Specification sheet

MadgeTech UltraShock Series User manual

MadgeTech

MadgeTech UltraShock Series User manual

MadgeTech HiTempl40-PT-5 Specification sheet

MadgeTech

MadgeTech HiTempl40-PT-5 Specification sheet

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech pHTemp2000 Specification sheet

MadgeTech

MadgeTech pHTemp2000 Specification sheet

MadgeTech Temp1000IS Specification sheet

MadgeTech

MadgeTech Temp1000IS Specification sheet

MadgeTech pHTemp101 User manual

MadgeTech

MadgeTech pHTemp101 User manual

MadgeTech RHTemp101A Specification sheet

MadgeTech

MadgeTech RHTemp101A Specification sheet

MadgeTech VFC2000 User manual

MadgeTech

MadgeTech VFC2000 User manual

MadgeTech TempRetriever User manual

MadgeTech

MadgeTech TempRetriever User manual

Popular Data Logger manuals by other brands

Aqualytic AL15 instruction manual

Aqualytic

Aqualytic AL15 instruction manual

Delta OHM HD32MT.1 quick start

Delta OHM

Delta OHM HD32MT.1 quick start

Delta OHM HD32.8.8 manual

Delta OHM

Delta OHM HD32.8.8 manual

red lion Data Station Plus manual

red lion

red lion Data Station Plus manual

SignalFire RANGER Wall Mount manual

SignalFire

SignalFire RANGER Wall Mount manual

T&D TR-71U user manual

T&D

T&D TR-71U user manual

JRI Spy RF AIR manual

JRI

JRI Spy RF AIR manual

Avisaro M47724 quick guide

Avisaro

Avisaro M47724 quick guide

Honeywell CNI4 quick start guide

Honeywell

Honeywell CNI4 quick start guide

SolarEdge Data Logger installation guide

SolarEdge

SolarEdge Data Logger installation guide

Hobo MX2501 quick start

Hobo

Hobo MX2501 quick start

Dwyer Instruments LS1 Specifications-installation and operating instructions

Dwyer Instruments

Dwyer Instruments LS1 Specifications-installation and operating instructions

GRAPHTEC GL840 quick start guide

GRAPHTEC

GRAPHTEC GL840 quick start guide

Power One VSN-MGR-RES SERIES installation guide

Power One

Power One VSN-MGR-RES SERIES installation guide

Extech Instruments TM500-NIST user guide

Extech Instruments

Extech Instruments TM500-NIST user guide

Solar-Log 2050 Assembly guide

Solar-Log

Solar-Log 2050 Assembly guide

Extech Instruments CO210 user manual

Extech Instruments

Extech Instruments CO210 user manual

Racelogic Performance Box Touch V1 manual

Racelogic

Racelogic Performance Box Touch V1 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.