manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech EggTemp-RH Specification sheet

MadgeTech EggTemp-RH Specification sheet

EggTemp-RH
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 60°C (140°F).
Specications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com linf[email protected]
DOC12000035-00 REV 10 2015.03.13
EggTemp-RH
Egg Temperature and Humidity Data Logger
Description EggTemp-RH
Temperature Sensor Internal semiconductor
Temperature Range 0
°C
to +60 °C (+32
°F to +140 °F)
Temperature Resolution 0.1 °C
Temperature Accuracy ±0.5 °C
Humidity Sensor Internal semiconductor
Humidity Range 0 %RH to 95 %RH
Humidity Resolution 0.5 %RH
Humidity Accuracy +3.0 %RH
Memory 16,383/channel
Sample Rate 2 seconds up to 12 hours
RH Units %RH, dew pt., water vapor concentration (mg/ml)
Required Interface Package IFC202
Baud Rate 38,400
Typical Battery Life 1 year
Operating Environment
0 °C to +60 °C (+32 °F to +140 °F),
0 %RH to 95 %RH (non-condensing)
Submergible
No
Material
Enclosure: HDPE
Logger: Stainless Steel
Dimensions
2.25 in x 1.68 in dia. (57.15 mm x 42.67 mm)
Weight
2.02 oz (60 g)
Approvals -
Product User Guide
Product Notes
The EggTemp-RH consists of a temperature and humidity data logger inside an egg shaped
enclosure to simulate the humidity and temperature aects of a real egg.
LEDs
Once started, the green LED will ash every two seconds to indicate that the device is
running. The red LED will ash in two second intervals if there is an alarm condition.
Alarm Settings
To change the settings for the temperature alarm:
- Select Alarm Settings from the Device menu in the MadgeTech software. A window will
appear allowing the customer to set the high and low temperature alarms.
- Press Change to edit the values.
- Check Enable Alarm Settings to enable the feature. The values can be entered in the
eld manually or by using the scroll bars.
- Click Save to save the changes. To clear an active alarm, press Clear Alarm.
O-Rings
O-ring maintenance is a key factor when properly caring for the EggTemp-RH. The o-rings
ensure a tight seal and prevent liquid from entering the inside of the device.
Please refer to the application note “O-Rings 101: Protecting Your Data”, found on the
MadgeTech website, for information on how to prevent O-ring failure.
Installation Guide
Installing the Interface cable
- IFC202
Insert the device into a USB port. The drivers will install automatically.
- USB-1 or USB-101
Install the USB drivers from the USB Stick provided in the kit, then plug the USB cable into the
computer and the serial cable into the serial port.
Installing the software
Dowload the MadgeTech 4 Software from the website at www.madgetech.com/software-
download. Follow the instructions provided in the Wizard to complete download.
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Click the Communication Menu, then Auto Congure Port.
- After a moment, a box will appear stating that a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been congured for your logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Product User Guide
EggTemp-RH
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will ooad all recorded data onto
the PC.
Device Maintenance
Battery Replacement
Materials:
Replacement Battery (SR1154W)
- Remove the data logger from the egg enclosure
- Unscrew the knurled endcap on the data logger
- Tip the batteries (enclosed in a plastic sleeve) out of the enclosure tube.
- Use a small, dull, non-metallic tool (e.g. pen cap) to push the batteries out of the sleeve.
- Press the new batteries into the sleeve negative (-) end rst.
- Place the sleeved batteries in the enclosure tube positive (+) end rst.
- Screw the knurled cap back in place.
Recalibration
The EggTemp-RH standard calibration is one point at 25 °C and two points at 25 %RH and 75
%RH.
Call for custom calibration options to accommodate specic application needs.

Other MadgeTech Data Logger manuals

MadgeTech HiTemp140-5.25-TD Specification sheet

MadgeTech

MadgeTech HiTemp140-5.25-TD Specification sheet

MadgeTech TEMP1000EX User manual

MadgeTech

MadgeTech TEMP1000EX User manual

MadgeTech RFPulse2000A User manual

MadgeTech

MadgeTech RFPulse2000A User manual

MadgeTech Temp101A User manual

MadgeTech

MadgeTech Temp101A User manual

MadgeTech HiTemp140-FP Specification sheet

MadgeTech

MadgeTech HiTemp140-FP Specification sheet

MadgeTech RHTEMP1000 Specification sheet

MadgeTech

MadgeTech RHTEMP1000 Specification sheet

MadgeTech HiTemp140-FP User manual

MadgeTech

MadgeTech HiTemp140-FP User manual

MadgeTech HiTemp140-5.25 Specification sheet

MadgeTech

MadgeTech HiTemp140-5.25 Specification sheet

MadgeTech RHTemp101 User manual

MadgeTech

MadgeTech RHTemp101 User manual

MadgeTech PR1000EX-30A Specification sheet

MadgeTech

MadgeTech PR1000EX-30A Specification sheet

MadgeTech AVS140-6 Specification sheet

MadgeTech

MadgeTech AVS140-6 Specification sheet

MadgeTech PR2000 Specification sheet

MadgeTech

MadgeTech PR2000 Specification sheet

MadgeTech ThermoVault Max Specification sheet

MadgeTech

MadgeTech ThermoVault Max Specification sheet

MadgeTech TSR101-5 User manual

MadgeTech

MadgeTech TSR101-5 User manual

MadgeTech RHTemp2000 User manual

MadgeTech

MadgeTech RHTemp2000 User manual

MadgeTech HiTemp140-PT Series Specification sheet

MadgeTech

MadgeTech HiTemp140-PT Series Specification sheet

MadgeTech PRTC210 User manual

MadgeTech

MadgeTech PRTC210 User manual

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech TCTemp2000 User manual

MadgeTech

MadgeTech TCTemp2000 User manual

MadgeTech Volt101A User manual

MadgeTech

MadgeTech Volt101A User manual

MadgeTech PR2009 Specification sheet

MadgeTech

MadgeTech PR2009 Specification sheet

MadgeTech Bridge101A-150 User manual

MadgeTech

MadgeTech Bridge101A-150 User manual

MadgeTech QuadTCTempV2 Specification sheet

MadgeTech

MadgeTech QuadTCTempV2 Specification sheet

MadgeTech QuadVoltV2 Specification sheet

MadgeTech

MadgeTech QuadVoltV2 Specification sheet

Popular Data Logger manuals by other brands

NexSens Technology CB-25 user guide

NexSens Technology

NexSens Technology CB-25 user guide

Hobo RXMOD-RXW Series quick start guide

Hobo

Hobo RXMOD-RXW Series quick start guide

METER GROUP Em50 Series quick start guide

METER GROUP

METER GROUP Em50 Series quick start guide

Dataq DI-4730 user manual

Dataq

Dataq DI-4730 user manual

Avisaro RS232 quick guide

Avisaro

Avisaro RS232 quick guide

Tera DLT-10 user manual

Tera

Tera DLT-10 user manual

Race Result Chip2Go Quick reference guide

Race Result

Race Result Chip2Go Quick reference guide

bluSensor AIR manual

bluSensor

bluSensor AIR manual

Eagle Tree Systems Dual A/D Expander V2 instruction manual

Eagle Tree Systems

Eagle Tree Systems Dual A/D Expander V2 instruction manual

WEBTEC HPM6000 quick start

WEBTEC

WEBTEC HPM6000 quick start

CONTROL SOLUTIONS VFC800-WIFI Product user guide

CONTROL SOLUTIONS

CONTROL SOLUTIONS VFC800-WIFI Product user guide

SIAP+MICROS t021 TLU User manual and maintenance

SIAP+MICROS

SIAP+MICROS t021 TLU User manual and maintenance

eGauge Systems LLC EG4030 Configuration guide

eGauge Systems LLC

eGauge Systems LLC EG4030 Configuration guide

Auta DIGITAL 730139 manual

Auta

Auta DIGITAL 730139 manual

A&D AD-1688 instruction manual

A&D

A&D AD-1688 instruction manual

WIS International WISARD-550 Operator's guide

WIS International

WIS International WISARD-550 Operator's guide

VOLTCRAFT WDL-TH operating instructions

VOLTCRAFT

VOLTCRAFT WDL-TH operating instructions

METIS V2 instruction manual

METIS

METIS V2 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.