manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech TSR101-EB User manual

MadgeTech TSR101-EB User manual

This manual suits for next models

4

Other MadgeTech Data Logger manuals

MadgeTech HiTemp140-FP-TSK Specification sheet

MadgeTech

MadgeTech HiTemp140-FP-TSK Specification sheet

MadgeTech RTDTemp101A User manual

MadgeTech

MadgeTech RTDTemp101A User manual

MadgeTech HiTemp140-FP Specification sheet

MadgeTech

MadgeTech HiTemp140-FP Specification sheet

MadgeTech HiTempl40-PT-5 Specification sheet

MadgeTech

MadgeTech HiTempl40-PT-5 Specification sheet

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech Rain101A Specification sheet

MadgeTech

MadgeTech Rain101A Specification sheet

MadgeTech Shock101-5 User manual

MadgeTech

MadgeTech Shock101-5 User manual

MadgeTech QuadVolt-100mV User manual

MadgeTech

MadgeTech QuadVolt-100mV User manual

MadgeTech VFC2000-MT Specification sheet

MadgeTech

MadgeTech VFC2000-MT Specification sheet

MadgeTech Shock101-5-EB Specification sheet

MadgeTech

MadgeTech Shock101-5-EB Specification sheet

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech Bridge120 Series User manual

MadgeTech

MadgeTech Bridge120 Series User manual

MadgeTech HiTemp1400 User manual

MadgeTech

MadgeTech HiTemp1400 User manual

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech RFpHTemp101A User manual

MadgeTech

MadgeTech RFpHTemp101A User manual

MadgeTech RHTemp2000 User manual

MadgeTech

MadgeTech RHTemp2000 User manual

MadgeTech pHTemp2000 Specification sheet

MadgeTech

MadgeTech pHTemp2000 Specification sheet

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech HiTemp150-TSK User manual

MadgeTech

MadgeTech HiTemp150-TSK User manual

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech HiTemp140-FP User manual

MadgeTech

MadgeTech HiTemp140-FP User manual

MadgeTech RFVolt2000A User manual

MadgeTech

MadgeTech RFVolt2000A User manual

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech

MadgeTech HiTemp140-M12 Specification sheet

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

Soil Instruments GTecLink user manual

Soil Instruments

Soil Instruments GTecLink user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TSR101-EB-5
Tri-Axial +5g, Transient Shock Data Logger with an Extended Battery Life
TSR101-EB-250
Tri-Axial +250g, Transient Shock Data Logger with an Extended Battery Life
TSR101-EB-100
Tri-Axial +100g, Transient Shock Data Logger with an Extended Battery Life
TSR101-EB-50
Tri-Axial +50g, Transient Shock Data Logger with an Extended Battery Life
TSR101-EB
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 54 °C (129 °F).
DOC-1164035-00 REV 8 01.23.2018
Description TSR101-EB
Acceleration Sensor Shock (3 axes)
Accelerometer Type MEMS Semiconductor
Acceleration Range
*See Table for DetailsAcceleration Resolution
Calibrated Accuracy
Memory 349,471/channel
Reading Rate 1,024Hz to 1 second
Frequency Response 0Hz to approximately 400Hz (50, 100 g)
Typical Battery Life 30 days typical
Required Interface Package IFC200
Baud Rate 115,200
Operating Environment -20 °C to +54 °C, 0 to 95%RH non-condensing
Dimensions 5.5” x 5.4” x 3.2” (140 mm x 137 mm x 80 mm)
Materials Anodized aluminum
Weight 5lbs (2.3kg)
Approvals CE
Range (g) +5 +50 +100 +250
Resolution (g) 0.01 0.05 0.1 0.2
Accuracy (g) +0.2 +1 +2 +4
*TSR101-EB Acceleration Range, Resolution and Accuracy
Product Information Card
www.calcert.com sales@calcert.com1.888.610.7664 0
5
10
15
20
25
30
Product Notes
How it Works
Once the logger is started samples are taken on each axis (X, Y and Z) every 1024Hz
(1ms). These samples are compared with the trigger values and if it crosses the threshold
value then it records the timestamp and starts logging the triggered data.
If the samples are not above the threshold value then it is logged as the pre-trigger data.
Since only 50 pre-trigger values can be recorded the data gets overwritten if the logger is
not triggered within 50 pre-trigger values.
The sampling frequency is the same for all reading rates therefore the samples are skipped
based on the reading rate. For example: if the reading rate is 512Hz the samples are taken
every 1ms but every other sample gets logged instead of logging every sample.
Trigger Settings
Below is a table of default trigger values based on the range of the logger. All axis are
enabled to check for triggers at these g levels.
To edit trigger values, select Start Device from the Start Menu. Click Yes, then select
Trigger Settings. Click the Change button. Each axis can be set to trigger at a certain g
force level. Check the Enable Trigger box to enable the trigger for that axis. The values
can be typed in manually or configured by using the slider control. Click Save to save the
changes.
To initiate the TSR101-EB to constantly sample, set the high and low trigger settings to 0g.
Axis Orientation
When the TSR101-EB is laying flat, with the label facing up,
the x-axis indicates left to right direction and will read ~0 g
when still. The y-axis reads in a top to bottom direction and
reads ~0 g when still. The z-axis reads perpendicular to the
other two axis, and will read ~1 g when still.
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
Installing the software
Insert the Software USB Stick in an open USB port. If the autorun does not appear, locate
the drive on the computer and double click on Autorun.exe. Follow the instructions
provided in the Wizard.
TSR101-EB Product Information Card
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials:
Phillips Screwdriver
Replacement Battery (MN1300)
- Remove the cover from the device by unscrewing the four screws.
- Tip out the battery holder. Note: Do not pull on the battery leads.
- Replace the 6 D-cell batteries and put the holder back into the device.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The TSR101-EB standard calibration is performed at 0 g for the x-axis, 0 g for the y-axis and
1 g for the z-axis.
Note: The shock parameters are not traceable to NIST.
Range 5 g 50 g 100 g 250 g
Trigger Value 2.5 g 25 g 52.5 g 120 g
Y-Axis
Z-Axis
X-Axis
www.calcert.com sales@calcert.com1.888.610.7664 0
5
10
15
20
25
30