manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech RHTemp101 User manual

MadgeTech RHTemp101 User manual

This manual suits for next models

2

Other MadgeTech Data Logger manuals

MadgeTech SHOCK300 Specification sheet

MadgeTech

MadgeTech SHOCK300 Specification sheet

MadgeTech Bridge101A User manual

MadgeTech

MadgeTech Bridge101A User manual

MadgeTech MicroTemp100 Specification sheet

MadgeTech

MadgeTech MicroTemp100 Specification sheet

MadgeTech RHTEMP1000 Specification sheet

MadgeTech

MadgeTech RHTEMP1000 Specification sheet

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech VFC2000 Specification sheet

MadgeTech

MadgeTech VFC2000 Specification sheet

MadgeTech PRTC110 User manual

MadgeTech

MadgeTech PRTC110 User manual

MadgeTech 902152-00 Specification sheet

MadgeTech

MadgeTech 902152-00 Specification sheet

MadgeTech Event101A User manual

MadgeTech

MadgeTech Event101A User manual

MadgeTech Shock101-5 User manual

MadgeTech

MadgeTech Shock101-5 User manual

MadgeTech PR1000 Specification sheet

MadgeTech

MadgeTech PR1000 Specification sheet

MadgeTech TSR101-5 User manual

MadgeTech

MadgeTech TSR101-5 User manual

MadgeTech Shock101-EB Specification sheet

MadgeTech

MadgeTech Shock101-EB Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech PRTemp140 Specification sheet

MadgeTech

MadgeTech PRTemp140 Specification sheet

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech HiTemp140X2 Series User manual

MadgeTech

MadgeTech HiTemp140X2 Series User manual

MadgeTech HiTemp140-FR Specification sheet

MadgeTech

MadgeTech HiTemp140-FR Specification sheet

MadgeTech QuadState User manual

MadgeTech

MadgeTech QuadState User manual

MadgeTech Therm-A-lert Specification sheet

MadgeTech

MadgeTech Therm-A-lert Specification sheet

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech Level1000 Specification sheet

MadgeTech

MadgeTech Level1000 Specification sheet

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

Soil Instruments GTecLink user manual

Soil Instruments

Soil Instruments GTecLink user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MadgeTech, Inc.
PO Box 50 lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
REV A 2008.07.08
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Product Information Card
RHTemp101 and RHTemp110 and
TempRetrieverRH
RHTemp110
Temperature and Humidity Recorder with 10 Year Battery Life
RHTemp101
Temperature and Humidity Recorder
Product Quick Reference Card
TempRetrieverRH
Temperature and Humidity Recorder with Pushbutton Start/Stop
Specication RHTemp101 RHTemp110 TempRetrieverRH
Temperature Sensor Internal semiconductor Internal semiconductor Internal semiconductor
Temperature Range –40 to +80°C –40 to +80°C -40 to +80°C
Temperature Resolution 0.1°C 0.1°C 0.1°C
Calibrated Accuracy +0.5°C +0.5°C +0.5°C
Humidity Sensor Internal semiconductor Internal semiconductor Semiconductor
Humidity Range 0 to 95%RH 0 to 95%RH 0 to 95%RH
Humidity Resolution 0.5%RH 0.5%RH 0.1%RH
Calibrated Accuracy +3.0%RH +3.0%RH +3.0%RH
Memory 21,845/channel 21,845/channel 16,383/channel
Sample Rate 2 seconds to 12 hours 2 seconds to 12 hours 5 seconds to 30 min.
LED Indicator Red Red Red & Green
RH Units %RH, dew pt., water vapor concentration (mg/ml)
Alarm Temperature No Temperature
Required Interface Package IFC110 or IFC200 IFC110 or IFC200 IFC110 or IFC200
Baud Rate 2,400 57,600 38,400
Typical Battery Life 1 year 10 years 1 year
Operating Environment –40 to +80°C, 0 to 95%RH (Non–Condensing)
Material ABS plastic ABS plastic ABS plastic
Dimensions
1.4” x 2.2” x 0.6”
(36mm x 56mm x 16mm)
1.7” x 2.3” x 0.8”
(44mm x 59mm x 21mm)
1.4” x 2.2” x 0.6”
(36mm x 56mm x 16mm)
Approvals CE CE CE
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
Device Maintenance
Battery Replacement
Materials:
Small Phillips Head Screwdriver
Replacement Battery (LTC-7PN)
- Puncture the center of the back label with the screw driver
and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit
board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT
SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE,
CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR
EXPLODE IF HEATED ABOVE 80°C (176°F).
Recalibration
The RHTemp101, RHTemp110 and TempRetrieverRH standard
calibration is one point at 25°C and two points at 25%RH and
75%RH.
Pricing:
Recalibration traceable to NIST $90.00
Recalibration $70.00
Additional:
As Found Data $15.00
Additional Points $15.00 per point
To send the devices back, visit www.madgetech.com, select Services
then RMA Process.
RHTemp101, RHTemp110 and TempRetrieverRH Product Quick Reference Card
Product Notes
LEDs
Once started, the LED will flash at the selected reading rate to
indicate that the device is running. The LED will flash in one
second intervals if there is an alarm condition.
Alarm Settings
To change the settings for the temperature alarm;
- Select Alarm Settings from the Device menu in the MadgeTech
software. A window will appear allowing the customer to set the
high and low temperature alarms.
- Press Change to edit the values.
- Check Enable Alarm Settings to enable the feature. The values
can be entered in the field manually or by using the scroll bars.
- Click Save to save the changes. To clean an active alarm, press
Clear Alarm.
Installation Guide
Installing the Interface cable
- IFC200, IFC202 or IFC300
Refer to the “Quick Start Guide” included in the package.
- IFC110, IFC102 or IFC103
Plug the serial cable into the port and verify it is secure.
- USB-1 or USB-101
Install the USB drivers from the CD provided in the kit, than
plug the USB cable into the computer and the serial cable into
the serial port.
Installing the software
Insert the Software CD in the CD-ROM Drive. If the autorun
does not appear, locate the drive on the computer and double
click on Autorun.exe. Follow the instructions provided in the
Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface
cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box similar to the following will appear;
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your
logger. These settings can be found under the Communication
Menu.
Note: For additional installation instructions refer to your “Data
Logger & Software Operating Manual”.
Device Operation
Starting the data logger
- Click Device Menu then
Start Device.
- Choose the desired start
method.
- Choose the start parameters
by selecting a Reading Rate
suitable for your application.
- Enter in any other desired
parameters and click Start.
- A box will appear stating the
data logger has been started.
Click OK.
- Disconnect the data logger from the interface cable and
place it in the environment to measure.
Note: The device will stop recording data when the end of
memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the
computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will
offload all recorded data onto the PC.
Technical Support
Visit www.madgetech.com, or call (603) 456-2011.
Technical support is also available by e-mailing
[email protected]