manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech TransiTemp-EC Specification sheet

MadgeTech TransiTemp-EC Specification sheet

This manual suits for next models

1

Other MadgeTech Data Logger manuals

MadgeTech HiTemp150 User manual

MadgeTech

MadgeTech HiTemp150 User manual

MadgeTech Shock101-100 Specification sheet

MadgeTech

MadgeTech Shock101-100 Specification sheet

MadgeTech VFC2000 Specification sheet

MadgeTech

MadgeTech VFC2000 Specification sheet

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech TSR101 Series User manual

MadgeTech

MadgeTech TSR101 Series User manual

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech PR2000 Specification sheet

MadgeTech

MadgeTech PR2000 Specification sheet

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech Bridge101A-30 User manual

MadgeTech

MadgeTech Bridge101A-30 User manual

MadgeTech RHTEMP1000EX Specification sheet

MadgeTech

MadgeTech RHTEMP1000EX Specification sheet

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech Temp1000IS Specification sheet

MadgeTech

MadgeTech Temp1000IS Specification sheet

MadgeTech ThermoVault Max Specification sheet

MadgeTech

MadgeTech ThermoVault Max Specification sheet

MadgeTech HiTemp140-5.25-TD Specification sheet

MadgeTech

MadgeTech HiTemp140-5.25-TD Specification sheet

MadgeTech PR2009 Specification sheet

MadgeTech

MadgeTech PR2009 Specification sheet

MadgeTech LF101A Specification sheet

MadgeTech

MadgeTech LF101A Specification sheet

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech HiTemp140-FR-TSK Specification sheet

MadgeTech

MadgeTech HiTemp140-FR-TSK Specification sheet

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech State101A User manual

MadgeTech

MadgeTech State101A User manual

MadgeTech Temp1000IS Specification sheet

MadgeTech

MadgeTech Temp1000IS Specification sheet

MadgeTech Level1000 Specification sheet

MadgeTech

MadgeTech Level1000 Specification sheet

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech HiTemp140-FR Specification sheet

MadgeTech

MadgeTech HiTemp140-FR Specification sheet

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

Soil Instruments GTecLink user manual

Soil Instruments

Soil Instruments GTecLink user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TransiTemp-EC
In-Transit Temperature
Data Logger
PRODUCT
USER GUIDE
To view the full MadgeTech product line, visit
our website at madgetech.com.
TABLE OF CONTENTS
2Product Overview
2Installation Guide
2Device Operation
3Device Maintenance
4Need Help?
Product User Guide | 2
TransiTemp-EC
PRODUCT USER GUIDE
Product Overview
The TransiTemp-EC temperature data logger is designed
for high volume, low cost in-transit recording. It has
a custom molded case with a handle for convenient
attachment and comes in single and multi-use versions.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC203 (sold separately) — Follow the instructions
provided in the Installation Wizard to install the USB
Interface Drivers. Drivers can also be downloaded from the
MadgeTech website at madgetech.com.
Ordering Information
• 901749-00 — TransiTemp-EC
• 901752-00 — TransiTemp-EC-Multi
• 900313-00 — IFC203 Interface Cable
• 900036-00 — CR2032 Replacement Battery
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the data logger.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. The data logger will automatically appear under
Connected Devices within the software.
4. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
5. The status of the device will change to Running,
Waiting to Start or Waiting to Manual Start,
depending upon your start method.
6. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
1. Connect the data logger to the computer with the
interface cable.
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download.
4. Downloading will offload and save all the recorded
data to the PC.
Product User Guide | 3
TransiTemp-EC
PRODUCT USER GUIDE
Device Operation (cont’d)
Marking Feature
A date and time stamp may be placed in the recorded
data by holding the push button for 2 seconds to date and
time stamp data point while logging.
Alarm Settings
To change the settings for the alarm:
1. In the Connected Devices panel, select the intended
device to change the alarm settings.
2. On the Device tab, in the Information group, click
Properties. Users can also right-click on the device and
select Properties in the context menu.
3. A window will appear allowing to set the high and low
temperature alarms.
4. Press Change to edit the values.
5. Check Enable Alarm Settings to enable the feature
and check each high and low alarm box to activate it.
The values can be entered in the field manually or by
using the scroll bars.
6. Click Apply to write the settings to the device. To clear
an active alarm, press the Clear Alarm button.
LED Indicators
Green LED blinks every 10 seconds to
indicate safe conditions during logging
Red LED blinks every 10 seconds to
indicate alarm criteria have been exceeded
Device Maintenance
Battery Replacement on TransiTemp-EC-Multi
Materials: CR2032 Battery
1. Gently pry the two halves of the enclosure apart.-
Remove the circuit board.
2. Use a small non-metallic device to push the coin-cell
battery out of its holder.
3. Hold down the pushbutton in the middle of the circuit
board and insert the new battery into the holder.
4. Release the pushbutton and watch to verify that the
LEDs blink. (If they do not, then you may have inserted
the battery upside down. Remove the battery and
try again.)
5. Replace the circuit board in the enclosure.
6. Press the two halves of the enclosure back together.
Note: The TransiTemp-EC (Single Use) must be returned to the factory for
battery replacement.
Recalibration
The TransiTemp-EC and TransiTemp-EC-Multi cannot be
recalibrated.
TransiTemp-EC
NEED HELP?
DOC-1115036-00 | REV 1 2021.03.09
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting
• Visit our Resource Library online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.