manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech pHTemp2000 User manual

MadgeTech pHTemp2000 User manual

pHTemp2000
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: MAY LEAK AND/OR FLAME IF OPENED, RECHARGED, CONNECTED IMPROPERLY, OR
DISPOSED OF IN FIRE.
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1176035-00 REV 11 2014.11.26
pHTemp2000
pH and Temperature Data Logger with LCD Display
Description pHTemp2000
pH input Connection Female BNC jack
pH Range -2.00 pH to +16.00 pH
pH Resolution 0.01 pH (0.1 mV)
Calibrated Accuracy +0.01 pH
Temperature Sensor 2, 3, or 4 wire 100 Ωplatinum RTD
Temperature Range -40 °C to +110 °C (-40 °F to +230 °F)
Temperature Resolution 0.01 °C (0.018 °F)
Calibrated Accuracy +0.15 °C @ 25 °C Ambient
Memory 131,071/channel
Reading Rate 1 reading every 2 seconds up to 1 reading every 24 hours
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 1 year with display off, 30 days with
continuous LCD and no backlight
Operating Environment -5 °C to +50 °C (+23 °F to +122 °F),
0 to 95 %RH (non-condensing)
Material Black Anodized Aluminum
Dimensions 4.8 in x 3.3 in x 1.25 in (122 mm x 84 mm x 32 mm)
Weight 16 oz (440 g)
Approvals CE
Product Information Card
Product Notes
The pHTemp2000 is a pH and temperature data logger with LCD display. The convenient
LCD provides access to the current pH and temperature readings, as well as minimum,
maximum and average statistics.
Backlight
The backlight uses up a significant amount of battery life, it can be configured to auto
shut-off when not in use. Refer to the manual for more details.
Using the pHTemp2000
1. The pH electrode should have a BNC output connection, or an appropriate adapter.
Select a probe with an output impedance less than 300 megaohms at the desired
temperature.
2. The temperature probe must be a 100 Ωplatinum RTD, in the standard 2-,3- or 4-wire
configuration. The pHTemp2000 is designed to achieve exceptional accuracy with the
4-wire probe, but will still yield measurements better than required for a
pH-measurement with the 2- or 3-wire probes.
3. Insure that the probe you select can be connected to the pHTemp2000 RTD input by
selecting a probe with lead wires, or by attaching an adapter that will allow you to
connect wire leads to the probe.
4. Connect the probes to the data logger.
5. Refer to the description of your pH probe for a calibration procedure.
100 Ω, 2 or 4 wire RTD probes are recommended for the most accurate performance.
Most 100 Ω, 3 wire RTD probes will work, but MadgeTech cannot guarantee the accuracy.
To determine whether or not the 3-wire RTD probe will work, the resistance between the
two same colored wires should be less than 1 Ω. (Note: Please contact the manufacturer of
the RTD probe for questions on the resistance)
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
Installing the software
Insert the Software USB Stick in an open USB port. If the autorun does not appear, locate
the drive on the computer and double click on Autorun.exe. Follow the instructions
provided in the Wizard.
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
pHTemp2000 Product Information Card
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials:
3/32” HEX Driver (Allen Key)
Replacement Battery (U9VL-J)
- Remove the back cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
-Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely. Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The pHTemp2000 standard calibration is performed at 50 Ωand 150 Ωfor the RTD channel
and 0 mV and 250 mV for the pH channel.
Note: MadgeTech does not offer calibration of pH inputs in combination with a pH electrode or probe.
Pricing:
Recalibration traceable to NIST $110.00
Recalibration $70.00
Additional Services:
Custom calibration and verification point options available, please call for pricing.
Call for custom calibration options to accommodate specific application needs.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting
www.madgetech.com, then under the services tab, select RMA Process.
KEY
1- Reference (-)
2- Measurement(-) Input
3- Measurement (+) Input
4- Excitation Current Out (+)

Other manuals for pHTemp2000

1

Other MadgeTech Data Logger manuals

MadgeTech HiTemp140-FR Specification sheet

MadgeTech

MadgeTech HiTemp140-FR Specification sheet

MadgeTech Shock101-100 Specification sheet

MadgeTech

MadgeTech Shock101-100 Specification sheet

MadgeTech UltraShock Series User manual

MadgeTech

MadgeTech UltraShock Series User manual

MadgeTech HITEMP140-M12 Specification sheet

MadgeTech

MadgeTech HITEMP140-M12 Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech Shock101-5-EB Specification sheet

MadgeTech

MadgeTech Shock101-5-EB Specification sheet

MadgeTech State101A User manual

MadgeTech

MadgeTech State101A User manual

MadgeTech DHS User manual

MadgeTech

MadgeTech DHS User manual

MadgeTech TCTemp1000 User manual

MadgeTech

MadgeTech TCTemp1000 User manual

MadgeTech UltraShock-EB-5 User manual

MadgeTech

MadgeTech UltraShock-EB-5 User manual

MadgeTech UltraShock-5-EB User manual

MadgeTech

MadgeTech UltraShock-5-EB User manual

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech MadgeNet RFRHTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNet RFRHTemp2000A Specification sheet

MadgeTech CTL2000 User manual

MadgeTech

MadgeTech CTL2000 User manual

MadgeTech Pulse101A User manual

MadgeTech

MadgeTech Pulse101A User manual

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech RFOT Specification sheet

MadgeTech

MadgeTech RFOT Specification sheet

MadgeTech QuadRTDTempV2 Specification sheet

MadgeTech

MadgeTech QuadRTDTempV2 Specification sheet

MadgeTech RFpHTemp101A User manual

MadgeTech

MadgeTech RFpHTemp101A User manual

MadgeTech Bridge101A-30 User manual

MadgeTech

MadgeTech Bridge101A-30 User manual

MadgeTech HITEMP140-1 Specification sheet

MadgeTech

MadgeTech HITEMP140-1 Specification sheet

MadgeTech PR2000 Specification sheet

MadgeTech

MadgeTech PR2000 Specification sheet

MadgeTech RHTemp2000 User manual

MadgeTech

MadgeTech RHTemp2000 User manual

MadgeTech SHOCK300 Specification sheet

MadgeTech

MadgeTech SHOCK300 Specification sheet

Popular Data Logger manuals by other brands

Danelec DM100-2014 Operator's manual

Danelec

Danelec DM100-2014 Operator's manual

Omega OM-USB-2404-UI user guide

Omega

Omega OM-USB-2404-UI user guide

PCE Instruments PCE-HT 71N user guide

PCE Instruments

PCE Instruments PCE-HT 71N user guide

Steren 300-500 quick start guide

Steren

Steren 300-500 quick start guide

Arexx TL-300 manual

Arexx

Arexx TL-300 manual

Keithley KUSB-3116 Getting started manual

Keithley

Keithley KUSB-3116 Getting started manual

Fluke 1738/B user manual

Fluke

Fluke 1738/B user manual

SOLIS W4G Quick installation manual

SOLIS

SOLIS W4G Quick installation manual

Microtronics myDatalogEx user manual

Microtronics

Microtronics myDatalogEx user manual

T&D TR7 Series user manual

T&D

T&D TR7 Series user manual

EIJKELKAMP CBR user manual

EIJKELKAMP

EIJKELKAMP CBR user manual

Grosvenor IT31 user guide

Grosvenor

Grosvenor IT31 user guide

SS Telecoms SS-68BB user manual

SS Telecoms

SS Telecoms SS-68BB user manual

X2E XORAYA Z7 user manual

X2E

X2E XORAYA Z7 user manual

beadedstream D605 Installation & quick start guide

beadedstream

beadedstream D605 Installation & quick start guide

Marathon EDL-4S quick start guide

Marathon

Marathon EDL-4S quick start guide

infoAgro THI operating instructions

infoAgro

infoAgro THI operating instructions

METER ZL6 Replacement

METER

METER ZL6 Replacement

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.