HYPER150 EC
EC Inline Axial Duct Fan with App Control
Thank you for purchasing this quality EC inline axial duct fan.
To ensure correct function and safety, please read all instructions before using the product and keep all instructions for future reference.
TECHNICAL DATA
Description Order Code
EC Inline Axial Duct Fan FAN7000
Order Code FAN0085
Motor EC motor
Supply 110-240V AC, 50/60Hz
Wattage 18W
Fan Performance 105 l/s, 380m3/hr (free air performance)
Max. Pressure 91Pa
Housing Die cast aluminium
Impeller & Outer Rotor PBT plastic
Max. Operating Temp 45ºC
IP Rating IP44
Compliance AS/NZS60335.2.80
When using electrical appliances, basic safety precautions should always
be followed to reduce the risk of fire, electrical shock and personal injury.
This 150mm diameter EC inline axial duct fan is suitable for straight forward
domestic bathroom ventilation applications.
The high speed brushless EC motor, fitted with integral ball bearings, mean a
long service life and a quieter operation. These fans are generally mounted in
the ceiling cavity to exhaust air from interior vents to the outside. The compact
design, low profile, ease of mounting and IP rating to IP44 ensure a straight
forward installation.
Suitable for extracting air from toilets and bathrooms. Ideal for the supply of fresh
air to stale enclosed areas.
Product A B C D
Hyper150 EC 200 143 170 185
DIMENSIONS A C
BD
0
20
40
60
70
80
90
100
Static Pressure (Pa)
20 40 60 80 100 120
l/s 0
0
m3/hr 50 100 200 250 300 400350150 450
10
30
50
HYPER150 EC
EC Inline Axial Duct Fan with App Control
IMPORTANT
This EC inline axial duct fan must be installed by a registered electrician and its installation and connection to the power supply must comply with all
current wiring rules and regulations including the latest edition of AS/NZS3000 .
The power supply cable must be suitably rated by a registered electrician to satisfy the total load on that circuit.
The 10m control cable connects the wall controller to the EC inline axial duct fan as shown below. The EC inline axial duct fan should not be powered
while connecting the controller. A FAN2444 fully adjustable fan run-on timer (not supplied) must be used If timer switching is preferred.
EC INLINE AXIAL DUCT FAN INSTALLATION AND ELECTRICAL CONNECTION MUST
BE CARRIED OUT BY A REGISTERED ELECTRICIAN
WARNING
1. This EC inline axial duct fan may only be used as recommended by the manufacturer in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to persons. Contact the manufacturer, or local agent, if required.
2. Isolate the mains supply before making any electrical connections. This system should be installed by a registered electrician.
3. Ensure the EC inline axial duct fan is properly earthed.
4. The EC inline axial duct fan must be able to be isolated from the power by means of a disconnect switch meeting current electrical regulations.
5. The EC inline axial duct fan is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
6. Children should be supervised to ensure that they do not play with the EC inline axial duct fan.
IMPORTANT CONSIDERATIONS
Planning can make a big difference to the installation time and your satisfaction with the operation of the unit.
1. Remove the unit from its packaging and check to make sure it is in good condition before using.
2. Do not let children play with packaging.
3. Check the household voltage to ensure it matches the EC inline axial duct fan’s rated specification.
4. Check the power cord and plug carefully before using to ensure there is no damage.
5. Before unplugging the power cord, be sure to turn off the power. When energizing the unit, be sure your hands are dry to prevent electric shock.
6. This EC inline axial duct fan is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials away from the
EC inline axial duct fan and keep them away from the sides and rear.
7. Do not use near or in the immediate vicinity of a bath or swimming pool or any wet areas.
8. To protect against electric shock, do not immerse cord or plug in water or any other liquids.
9. Do not insert or allow foreign objects to enter any ventilation openings, as this may cause an electric shock, fire or damage to the EC inline axial duct
fan.
10. Do not put fingers or foreign objects into the grille while in operation.
11 Any changes, or modifications, made, or attempted, to this product, without the prior written approval of the manufacturer, will void any, and all,
stated warranties.
12. To prevent overheating of this appliance, keep the air inlets and outlets clean and free of anything that may cause blockage. Check all inlets and
outlets from time to time to ensure it is clear of any dirt or dust accumulation. DO NOT COVER.
13. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
14. This product contains recyclable materials. Do not dispose of this product as unsorted council waste. Please contact your local council for
the nearest collection point.
15. Ensure that the EC inline axial duct fan is switched off from the supply mains before removing the guard
16. Ensure that the EC inline axial duct fan is to be installed so that the blades are more than 2,3 m above the floor
17. Ensure that precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances
18. For equipment with Type Y attachment, if the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified
persons in order to avoid a hazard.
ELECTRICAL CONNECTIONS
Mains Control
Speed
Control
Potentiometer
BROWN
WHITE
BLUE
BLACK
GREEN/YELLOW
RED
LIVE
EARTH
NEUTRAL
HYPER150 EC
EC Inline Axial Duct Fan with App Control
The plastic spigots have been designed for easy mounting onto a flat solid surface such as the top plate of a wall partition, or ceiling joist, as found in a
roof cavity or, alternatively, to avoid possible resonance effects the motor can be suspended from the rafters.
BEFORE INSTALLING THE EC INLINE AXIAL DUCT FAN, MAKE SURE YOU HAVE TURNED OFF THE MAIN
ELECTRICITY SUPPLY. DO NOT TURN IT BACK ON UNTIL THE EC INLINE AXIAL DUCT FAN IS FULLY
INSTALLED AND READY TO USE.
ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN ACCORDANCE
WITH THE LATEST WIRING RULES AS/NZS3000.
INSTALLATION
Flexible duct
Internal grille
External grille
EC Inline axial duct fan
screwed to the joist
TYPICAL INSTALLATION
PUB1646 2011
Specifications are subject to change without notice
Manrose is proudly distributed by Simx Limited
PO Box 14 347, Panmure, Auckland, NZ. Technical Support (09) 259 1662
e: [email protected] | www.simx.co.nz | www.manrose.com.au
Simx Warranty Information
In this warranty:
We means Simx;
You means the consumer of the Goods
Supplier means the authorised distributor or retailer that sold you the Goods in New Zealand or Australia; and
Goods means the Simx product accompanied by this warranty and purchased in New Zealand or Australia.
The benefits provided to you under the following warranty are in addition to any other rights and remedies available
to you under the law:
1. If, during the time from the date of purchase (Warranty Period), there is a defect in the Goods due to improper
workmanship or material, we will replace or repair the Goods without charge. Any replacement product is
warranted only for the time remaining on the original Warranty Period.
2. We are not obliged to replace or repair the Goods under clause 1 if the Goods have been improperly stored,
installed, connected, used, operated, repaired, damaged, abused, tampered with, altered (without our written
approval), or not maintained in accordance with our recommended installation, connection and operating
instructions.
3. We exclude liability for:
a) consequential loss or any other loss or damage caused to property or persons arising from any cause
whatsoever;
b) damage to consumable items such as lamps and starters; and
c) damage arising from normal wear and tear.
4. In order to claim under this warranty you must, within the Warranty Period, return the Goods to the Supplier,
together with the original proof of purchase including the details below:
Supplier Name _____________________________
Date of Purchase _____________________________
Model Number _____________________________
Invoice/Receipt No. _____________________________
5. This warranty does not cover the cost of claiming under the warranty or transporting the Goods to and from the
Supplier.
Our Goods come with guarantees that cannot be excluded under the New Zealand and Australian Consumer Law.
You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the Goods repaired or replaced if the Goods fail to be of
acceptable quality and the failure does not amount to a major failure.
To speak to someone about your Simx product or claiming under this warranty, please contact:
Simx Ltd New Zealand
p: +64 9 259 1660 f: +64 9 259 1661
www.simx.co.nz
WESTAFLEX
HVAC Distributor within Australia
p: 03 9458 2122 e: sales@westaflex.com.au
www.westaflex.com.au

This manual suits for next models

2

Other Manrose Fan manuals

Manrose Showerlite LEDSLKTC User manual

Manrose

Manrose Showerlite LEDSLKTC User manual

Manrose FAN0531 User manual

Manrose

Manrose FAN0531 User manual

Manrose Classic Series User manual

Manrose

Manrose Classic Series User manual

Manrose FAN0616 User manual

Manrose

Manrose FAN0616 User manual

Manrose FAN7183 User manual

Manrose

Manrose FAN7183 User manual

Manrose FAN0531 User manual

Manrose

Manrose FAN0531 User manual

Manrose Classic Series User manual

Manrose

Manrose Classic Series User manual

Manrose FAN2303 User manual

Manrose

Manrose FAN2303 User manual

Manrose EXTRACT-A-LITE Service manual

Manrose

Manrose EXTRACT-A-LITE Service manual

Manrose intellivent 2.0 User manual

Manrose

Manrose intellivent 2.0 User manual

Manrose HYPER150 User manual

Manrose

Manrose HYPER150 User manual

Manrose FAN0085 User manual

Manrose

Manrose FAN0085 User manual

Manrose FAN2040 User manual

Manrose

Manrose FAN2040 User manual

Manrose Aria 250 Motor User manual

Manrose

Manrose Aria 250 Motor User manual

Manrose 100T Assembly instructions

Manrose

Manrose 100T Assembly instructions

Manrose LED Series User manual

Manrose

Manrose LED Series User manual

Manrose CRA100HT&T User manual

Manrose

Manrose CRA100HT&T User manual

Manrose Quiet Fan Conceal X5 S Assembly instructions

Manrose

Manrose Quiet Fan Conceal X5 S Assembly instructions

Manrose CRA100T User manual

Manrose

Manrose CRA100T User manual

Manrose FAN7366 User manual

Manrose

Manrose FAN7366 User manual

Manrose PRO Series User manual

Manrose

Manrose PRO Series User manual

Manrose VIVO FAN7291 User manual

Manrose

Manrose VIVO FAN7291 User manual

Manrose FAN0148 User manual

Manrose

Manrose FAN0148 User manual

Manrose MANI3000N Assembly instructions

Manrose

Manrose MANI3000N Assembly instructions

Popular Fan manuals by other brands

iGenix DF1656 user manual

iGenix

iGenix DF1656 user manual

Flex-a-Lite 475 installation instructions

Flex-a-Lite

Flex-a-Lite 475 installation instructions

Beacon LUCCI AIRFUSION HAVANA installation instructions

Beacon

Beacon LUCCI AIRFUSION HAVANA installation instructions

Bryant ERVBBLHA Series installation instructions

Bryant

Bryant ERVBBLHA Series installation instructions

Daikin AVV Installation and maintenance manual

Daikin

Daikin AVV Installation and maintenance manual

Craftmade SOE54AGV5 installation guide

Craftmade

Craftmade SOE54AGV5 installation guide

ARDES AR5F02P Instructions for use

ARDES

ARDES AR5F02P Instructions for use

Unold SENZA Instructions for use

Unold

Unold SENZA Instructions for use

Maico EV 31 Mounting and operating instructions

Maico

Maico EV 31 Mounting and operating instructions

Lasko U35115 operating manual

Lasko

Lasko U35115 operating manual

Hunter Swanson installation manual

Hunter

Hunter Swanson installation manual

MacroAir Technologies WhisperFoil installation manual

MacroAir Technologies

MacroAir Technologies WhisperFoil installation manual

Quarrix StormStop installation instructions

Quarrix

Quarrix StormStop installation instructions

Meltem M-WRG-II Series Dismantling Instructions

Meltem

Meltem M-WRG-II Series Dismantling Instructions

NSA TF-31RC instruction manual

NSA

NSA TF-31RC instruction manual

Marley H3 user manual

Marley

Marley H3 user manual

IRIS WOOZOO PCF-HE18R manual

IRIS

IRIS WOOZOO PCF-HE18R manual

SOLIS VIVALDI 751 user manual

SOLIS

SOLIS VIVALDI 751 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.