Installation Instructions Specifications are subject to change without notice Page 1
QUIET 125mm Extraction Fan Kit
Mounting Switching Order Code
Through Wall Standard FAN7187
Timer FAN7188
For best results, Simx recommend this product for bathrooms.
Following these installation instructions, this product will comply with the G4
Building Code for bathrooms once installed.
The Healthy Homes Standard requirement for bathroom installation in a rental
property is also met.
DIMENSIONS
SPECIFICATIONS
Duct
(mm)
Max.
Fan Watts
(W)
Max.
Fan Pressure
(Pa)
Free Air Fan Performance Specific
Fan Power
(W/l/s)
Sound
dB(A)
Operating
Temperature
(max.)
IP Rating
(l/s) (m3/hr)
125 15 68 54 194 0.28 38 40°C IPX4
Compliance: AS/NZS60335-2.80:2016
A
D
F
C E H
B
G
C
H
CONTENTS
125mm x 375mm Weatherproof
Axial Fan Aluminium Semi-Rigid Duct Cowl
CAUTION
• Before use, please check that the supply voltage and that of the appliance are the same (see product rating label).
• All wiring and wiring connections must comply with all current national wiring rules and regulations including AS/NZS3000:2018, or latest
edition thereof.
• Any changes or modifications made or attempted to this product, without the prior written approval of the manufacturer, will void any and all
stated warranties.
• This fan is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they are capable of, and have been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
• Precautions must be taken to avoid the back flow of combustion gases from the open flue of gas or other fuel-burning appliances in the room,
or from other rooms. These gases can potentially result in carbon monoxide poisoning. Open flued gas appliances should be tested by a
competent person, after fan installation, to ensure that back flow of combustion gases does not occur.
WARNING
• Do not insert or allow foreign objects to enter any ventilation openings, as this may cause an electric shock, fire or damage to the fan.
• Do not put fingers or foreign objects into the grille while in operation.
• To prevent overheating of this fan, keep the air inlets and outlets clean and free of anything that may cause blockage. Check all inlets and
outlets from time to time to ensure it is clear of any dirt or dust accumulation. DO NOT COVER.
• Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
• This product contains recyclable materials. Do not dispose of this product as unsorted council waste. Please contact your local council for the
nearest collection point.
WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED TO REDUCE THE RISK OF PROPERTY DAMAGE OR PERSONAL INJURY.
ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN
ACCORDANCE WITH THE LATEST WIRING RULES AS/NZS3000.
Cut-Out Size A B C D E F G H
140 160 30 125 375 120 100 29 187