User’s Manual
LFP-900W-4815M Lithium Ion Battery Charger
User’s Manual
Battery ChargerBattery Charger
©2018 MASHIN ELECTRIC Corp.
All rights reserved. All brand names and trademarks are the properties of their respective owners.
The specifications are subject to change without notice.
MASHIN ELECTRIC CORP.
10-33, Dashanjiao,Madou Dist, Tainan 721,TAIWAN R.O.C
TEL:+886-6-5702066 FAX:+886-6-5702840
Website: www.mashin.com.tw
Features
How to use
LED Indicator
91%@230VAC).
Adopts the most advanced Switching-Mode control technology.
1.
Meets International Energy Efficiency and the efficiency can up to
2.
Design, Develop and Made in Taiwan.
3.
Forced On Charging Mode: The BMS of Lithium Battery will cut off the ouput when it
4.
Smart Charging Mode: Increase the battery efficiency and extend the service life effectively.
5.
Detecting Battery Status.
6.
Over-temperature Protection: When temperature is exceeded, it will lower down the output
7.
Reverse Polarity Protection: If the battery clamps are wrongly connected, it will ensure the8.
9.
10.
Power LED (RED)
Light On
RED Light On
Connect with AC Power
Charging
Status LED (RED and GREEN)
RED Light Flash Battery or Charger is faulty
GREEN Light On Charging is completed
Charging Curve
Troubleshooting
1. Pre-Charge 1: This stage actives only if the battery is severely discharged and
help to protect and recondition the cells against the damage.
2. Pre-Charge 2: Soft start, moderately charging in the begining to avoid the
peak current damages the cells.
3. Bulk: Charging with maximum current, the current is fixed according to the
maximum capability of the charger.
4. Absorption: Charging with constant voltage and declining current to equalize and
maximize up the battery capacity.
5. Testing / Cut Off: Test if the battery is in good condition.
6. Low Voltage Auto Re-Charge: Re-charge automatically if it detects the voltage is
dropped off.
Voltage
Current
Charging Stage
Time (hours)
is light.
Connect the AC plug and turn the『ON/OFF Switch』to ON and check if the Power LED
1.
Connect the output connector with battery and check if Status LED turns to Red.
2.
When charging is completed, the Status LED will turn to green and cut off the output.
3.
Connector Short Circuit:Use Forced On Charging Mode and it will back to Normal
4.
)
ProblemNo.
1
2
3
Check if AC plug is well-connected or if there is no power in
Check if output connector and battery are well-connected
Check if connection is correctly, do not reverse polarity
Check if battery voltage is within operating range
Please turn『ON/OFF Switch』to off and turn on again.
Solution
Power LED does not light on
when properly connected
Status LED is flashing after
charging
※ If there is still problem happens, please contact with original purchaser.
Connctor Open Circuit: Do not use Forced On Charging Mode.
is low voltage, over current or short circuit. To solve this situation, you could use this mode.
to protect the charger.
battery and charger will not damage.
there will be no spark.
Spark Protection: When battery clamps connect with the battery or touch together,
Disconnecting Protection: When charger and clamps are accidently disconnecting, the
charger will back to standby mode automatically.
Power LED
Forced On Connector
Status LED Battery ConnectionON/OFF Switch
(Battery is charging).
Charging after 60 seconds.
Check if『ON/OFF Switch』is in the ON position
Status LED does not light on
when properly connected
AC socket
If the Status LED is still flashing, then the charger should be
faulty.