EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Medela
  6. •
  7. Medical Equipment
  8. •
  9. Medela Invia Foam Dressing Kit User guide

Medela Invia Foam Dressing Kit User guide

Other Medela Medical Equipment manuals

Medela Invia Motion User manual

Medela

Medela Invia Motion User manual

Medela Invia Series User manual

Medela

Medela Invia Series User manual

Medela Supplemental Nursing System User manual

Medela

Medela Supplemental Nursing System User manual

Medela Invia Liberty User manual

Medela

Medela Invia Liberty User manual

Medela Invia Liberty User manual

Medela

Medela Invia Liberty User manual

Medela Thopaz User manual

Medela

Medela Thopaz User manual

Medela Invia Liberty User manual

Medela

Medela Invia Liberty User manual

Medela BiliBed User manual

Medela

Medela BiliBed User manual

Medela Invia Liberty User manual

Medela

Medela Invia Liberty User manual

Medela Thopaz User manual

Medela

Medela Thopaz User manual

Medela Apgar Timer User manual

Medela

Medela Apgar Timer User manual

Medela Dominant 50 User manual

Medela

Medela Dominant 50 User manual

Medela Basic User manual

Medela

Medela Basic User manual

Medela Starter SNS User manual

Medela

Medela Starter SNS User manual

Medela Vario User manual

Medela

Medela Vario User manual

Medela Invia Motion User manual

Medela

Medela Invia Motion User manual

Medela Thopaz User manual

Medela

Medela Thopaz User manual

Medela Clario User manual

Medela

Medela Clario User manual

Medela Invia Liberty User manual

Medela

Medela Invia Liberty User manual

Medela Invia Liberty User manual

Medela

Medela Invia Liberty User manual

Medela Thopaz+ User manual

Medela

Medela Thopaz+ User manual

Medela Swing User manual

Medela

Medela Swing User manual

Medela Vario 18 CA User manual

Medela

Medela Vario 18 CA User manual

Medela Lactina User manual

Medela

Medela Lactina User manual

Popular Medical Equipment manuals by other brands

TekTone Tek-CARE160 Installation and operation manual

TekTone

TekTone Tek-CARE160 Installation and operation manual

NeuroMetrix Quell 2.0 user manual

NeuroMetrix

NeuroMetrix Quell 2.0 user manual

AMT XLR8 Quick reference guide

AMT

AMT XLR8 Quick reference guide

EDAN SONOTRAX Pro user manual

EDAN

EDAN SONOTRAX Pro user manual

Restorative Therapies RT300 Service guide

Restorative Therapies

Restorative Therapies RT300 Service guide

Gendex Expert DC installation manual

Gendex

Gendex Expert DC installation manual

Dexcowin ADX4000W user manual

Dexcowin

Dexcowin ADX4000W user manual

Libelium MySignals user manual

Libelium

Libelium MySignals user manual

Acelity V.A.C.ULTA 4 user manual

Acelity

Acelity V.A.C.ULTA 4 user manual

Caputron ActivaDose II tDCS quick start guide

Caputron

Caputron ActivaDose II tDCS quick start guide

Plinth 2000 93CDT Service manual

Plinth 2000

Plinth 2000 93CDT Service manual

GE SENOGRAPHE 800T Operator's manual

GE

GE SENOGRAPHE 800T Operator's manual

GE Definium 5000 Operator's manual

GE

GE Definium 5000 Operator's manual

Kanmed GE-1380 user manual

Kanmed

Kanmed GE-1380 user manual

Huntleigh FD1 Instructions for use

Huntleigh

Huntleigh FD1 Instructions for use

Stryker SPR Plus Operation manual

Stryker

Stryker SPR Plus Operation manual

Tobii Dynavox I-Series user manual

Tobii Dynavox

Tobii Dynavox I-Series user manual

S-Capepod Evac Cocoon Step-by-step guide

S-Capepod

S-Capepod Evac Cocoon Step-by-step guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Dressing Application Guide
Invia®Foam Dressing Kit with FitPad
1. Thoroughly
clean and
debride the
wound.
Apply skin prep
to protect the
peri-wound
skin.
4. Rub the edges
of the foam to
remove any
loose
particles.
9. Select
appropriate
location for the
suction pad
(FitPad) to be
applied. Pinch
the film and cut
a small hole
(approx. 1 cm).
12. Attach the
dressing tubing
to the pump
tubing by
pushing the
Quick-connec-
tor together until
you hear a click.
2. If required,
apply a
non-adherent
contact layer
prior to placing
the foam into
the wound.
10. Peel the
backing
off the FitPad
to expose the
adhesive.
7. Now remove
the transparent
backing layer
labeled 2.
3. Cut the foam to
fit the size and
shape of the
wound. Do not
cut directly over
the wound.
6. Apply
transparent
film. Partially
peel back one
side of layer 1
and place the
adhesive side
down. Remove
the remaining
side of layer 1.
11. Place the
FitPad
centered over
the previously
cut hole in the
dressing.
Press firmly
for adher-
ence.
8. Remove the
perforated silver
colored tab on
the side. The
film should
extend 3–5 cm
beyond the
wound margin
to facilitate
adequate seal.
5. Place the foam
into the wound
cavity. Do not
tightly pack or
force foam into
areas of the
wound. Do not
allow the foam to
overlap onto
intact skin.
Invia NPWT instructions advise 24 hour therapy without interruption. If therapy is discontinued for more than 2 hours,
the dressing should be replaced and therapy restarted by a healthcare professional.
This Quick Card does not replace the instructions for use REF 200.8923.
The Invia Foam Dressing Kit with FitPad is intended to be used in conjunction with the Invia Motion and
Invia Liberty Negative Pressure Wound Therapy Systems (NPWT).
Invia®Gauze Dressing Kit with FitPad
CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
1. Thoroughly
clean and
debride the
wound.
Apply skin prep
to protect the
peri-wound
skin.
4. Saturate the
gauze with
the saline
provided.
9. Select
appropriate
location for the
suction pad
(FitPad) to be
applied. Pinch
the film and cut
a small hole
(approx. 1 cm).
12. Attach the
dressing tubing
to the pump
tubing by
pushing the
Quick-connec-
tor together until
you hear a click.
2. If required,
apply a
non-adherent
contact layer
prior to placing
the gauze into
the wound.
5. The gauze
should fit
loosely into
the wound bed.
Do not tightly
pack or force
gauze into
areas of the
wound.
10. Peel the
backing off
the FitPad
to expose the
adhesive.
7. Now remove
the transparent
backing layer
labeled 2.
3. Cut the gauze
to fit the size
and shape of the
wound. Do not
cut the gauze
directly over the
wound.
6. Apply
transparent
film. Partially
peel back one
side of layer 1
– place the
adhesive side
down. Remove
the remaining
side of layer 1.
11. Place the
FitPad
centered over
the previously
cut hole in the
dressing.
Press firmly
for adher-
ence.
8. Remove the
perforated silver
colored tab on
the side. The film
should extend
3–5 cm beyond
the wound
margin to
facilitate an
adequate seal.
© Medela AG/201.0869/2016-12/A
Medela US/1908565/A
Medela AG
Lättichstrasse 4b
6341 Baar, Switzerland
www.medela.com
Canada
Medela Canada Inc.
4160 Sladeview Cres., Unit #8
Mississauga, ON
L5L 0A1, Canada
Phone +1 800 435 8316
Fax +1 800 995 7867
info@medela.ca
www.medela.ca
USA
Medela LLC
1101 Corporate Drive
McHenry
IL 60050, USA
Phone +1 877 735 1626
Fax +1 815 307 8942
info-healthcar[email protected]
www.medela-healthcare.us
Local contact:
Invia NPWT instructions advise 24 hour therapy without interruption. If therapy is discontinued for more than 2 hours,
the dressing should be replaced and therapy restarted by a healthcare professional.
This Quick Card does not replace the instructions for use REF 200.9065.
The Invia Gauze Dressing Kit with FitPad is intended to be used in conjunction with the Invia Motion and
Invia Liberty Negative Pressure Wound Therapy Systems (NPWT).
Please contact us or your local Medela representative for details.
Dressing Application Guide