14
GB IRL AUS USA NZ CDN IND
Checks
Visual inspection: Check that tank [1], pump [2], hose line [3], piston pressure gauge [7],
shut-off valve [4] and nozzle[14] are undamaged.
Pay special attention to the connections between the tank – hose line and hose line –
shut-off valve and to the condition of the pump threading.
No leaks: Pump up the empty device to 2 bar. (Fig. 10)
ŹThe pressure must not decrease more than 0.5 bar within 30 minutes.
Function: Pull up the piston pressure gauge [7]. (Fig. 3)
ŹThe pressure must dissipate.
Activate the shut-off valve [4]. (Fig. 12)
ŹThe shut-off valve must open and close.
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
Making preparations
Observe the instructions in the section entitled "Safety".
1. Pull up the red button on the piston pressure gauge [7] until all excess pressure is
released from the tank (Fig. 3)
2. Press the piston rod with handle [9] down and turn into the lock.
ŹThe piston rod with handle is locked. (Fig. 5)
3. Unscrew the pump [2] from the tank. (Fig. 6)
4. Add the liquid to the tank [1]. (Fig. 7)
5. Where appropriate, add cleaning agent.
6. Check the filling level with the scale [10] on the tank. (Fig. 7)
7. Screw the pump [2] into the tank. (Fig. 8)
8. Press the piston rod with handle [9] down and turn out of the lock.
ŹThe piston rod with handle is unlocked. (Fig. 9)
9. Generate the desired pressure in the tank (Fig. 10).
The maximum pressure should not exceed 3 bar (red line on the piston pressure gauge,
Fig. 10). If the maximum pressure is exceeded, the safety valve will engage and release
the excess pressure.
10.Press the piston rod with handle [9] down and turn into the lock. (Fig. 5)
ŹThe piston rod with handle is locked.
Foaming
Observe the instructions in the section entitled "Safety".
Operate the device only while it is vertical or suspended upright and nearly vertical.
Observe the instructions of the substance manufacturer!
1. Hang the device over your shoulder. (Fig. 11)
2. Align the foam nozzle to the area to be sprayed with a distance of 50 / 70 cm.
3. Activate the shut-off valve [4]. (Fig. 12)
ŹSpraying may now begin.
4. Make certain the optimum spraying pressure is set on the piston pressure gauge [7]
(Fig. 10).