18
Removing intake and pressure valve
Fault Cause Remedy
No pressure builds up in
the device.
Lever [10] can be moved
very easily
Diaphragm [17] is defective. Replace the diaphragm.
(Fig. 18)
Foreign object prevents
closure of the pressure valve
[24] and / or intake valve [26].
Clean intake and / or pressure
valve. (Figs. 18, 19)
O-ring [29] incorrectly situa-
ted in the intake valve [26].
Insert O-ring correctly into the
intake valve. (Fig. 19)
Lever [10] is pulled
downwards.
Intake valve [26] dirty or
valve ball [28] sticking.
Clean intake valve. (Fig. 19)
Lever [10] is pulled
upwards.
Foreign object prevents
closure of the pressure valve
[24] or defective valve disc
[27] in the pressure valve.
Clean pressure valve or
replace valve disc. (Fig. 18)
Lever [10] locked or can
be moved downwards
with diculty only.
Diaphragm [17] is defective. Replace the diaphragm.
(Fig. 18)
Pressure valve [24] dirty. Clean pressure valve. (Fig. 18)
Nozzle [20] and / or Filter [22]
blocked.
Clean nozzle (Fig. 13) and / or
lter (Fig. 14).
Only a spray, emerges,
there is no atomization.
Nozzle insert [21] is missing. Position the insert in the nozzle.
(Fig. 13)
Liquid dripping from the
nozzle.
Foreign object in the nozzle
[20] and / or the insert [21].
Clean nozzle and / or insert.
(Fig. 13)
Device sprays only when
pumped.
Pressure vessel [15] comple-
tely lled with liquid
Pump device empty. Repeat
after 5 llings at the latest.
The shut-o valve does
not close.
Liquid emerges without
the lever being activated.
O-ring [33] of the pressure
bolt [35] not greased
O-ring [33] defective
Grease the O-ring of the pressu-
re bolt. (Fig. 20)
Replace the pressure bolt or
O-ring. (Fig. 20)
• Remove the pressure vessel [15] (see “Care and maintenance”).
Pressure valve:
d) Using the lling strainer [8], unscrew the pressure valve screw [24]. (Fig. 15)
Intake valve:
d) Screw o the hexagon nut [25] and take the cylinder [19] out of the tank. (Fig. 16)
e) Screw the valve screw [26] out of the cylinder [19]. (Fig. 17)
EN ENGLISH
Contact address for additional information → see title page.
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals.
Unless otherwise specied, we recommend that an expert carries out an external
test every 2 years and an internal test every 5 years as well as a strength test every
10 years.
Faults
Use only original spare and accessory parts.