Microframe Corporation Visual-Pager 3600 Series User manual

*B3611-7010*
SERIES 3600
Wireless Visual-Paging®
Multi-Number Capable
INSTALLATION & SPECIFICATION GUIDE
Manual No. B3611-7010
Updated: 11/2019
Rev: 1.2
Microframe Corporation | 604 South 12th Street | Broken Arrow, OK 74012
Local:918-258-4839 | Toll Free: 800-635-3811
www.microframecorp.com | support@microframecorp.com

Series 3600 2
Microframe Corporation www.microframecorp.com 1.800.635.3811
Limited Warranty Agreement
YourMicroframeSystemiswarrantedagainstfailure due to defects in workmanship or material for a period of one
(1) year from the date of purchase. Microframe Corporation will repair or replace any defective unit. Obvious
abuseormishandlingoftheunitisNOTcovered by this warranty.
Merchandise Return
If your Unit does not work satisfactorily, please give us a call. We may be able to clear up the problem by phone.
If it becomes necessary to return your Unit to the factory, please observe the following:
1. Place Unit in a sturdy box with sufficient packing material.
2. If requested, include the AC power adapter. It is not necessary to return the cable and connectors unless they
are the problem.
3. Return the system insured and prepaid. Microframe is not responsible for shipping damages and losses on
returned Units.
Warranty Service
For warranty service, please contact Microframe toll-free at 800-635-3811. One of our technicians will be glad to
assist you.
Assistance
For any product assistance or maintenance help, contact Microframe by either calling 800-635-3811 or e-mailing
Safety
Do not install substitute parts or perform any modification to the product without first contacting Microframe.
Disclaimer
We constantly strive to improve our products. Specifications are subject to change without notice.
Warning
All power adapters, line cords, and electrical equipment should be kept out of the reach of children and away
from water. (If you are installing cable in an air plenum area, such as a drop ceiling used for air return, you must
use plenum-rated cable. The cable supplied from Microframe is rated CL2 and is approved for indoor installation
everywhere except plenum areas.)
Life Support Policy
Microframe's products are not authorized for use as components in life support devices or systems without the
express written approval of the President of Microframe Corporation. As used herein:
1. Life support devices or systems are defined as systems which support or sustain life, and whose failure to
perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in a significant injury to the user or any one depending on the system.
2. A critical component is any component of a life support device or system whose failure to perform can be
reasonably expected to cause the failure of the life support device or system, or to affect its safety or
effectiveness.
FCC Notice (for wireless products only)
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.

Series 3600 3
Microframe Corporation www.microframecorp.com 1.800.635.3811
Series3600
InstallationandSpecificationGuide
Table of Contents
Visual-Pager® Displays 4
Visual-Pager® Installation, Operation, and Options 5
Visual-Pager® Programming Instructions 6
Multi-Number MultiPage Transmitter 8
TransmitterInstallation 9
Transmitter Operation 10
Transmitter Programming Options 11
Transmitter Programming Instructions 12
Troubleshooting 13
Appendix A: Changing the Transmitter Type 14
Model 3500 Specifications 15
Model 3430 Specifications 16
Model 3620 Specifications 17
Multipage Transmitter Specifications 18

Series 3600 4
Microframe Corporation www.microframecorp.com 1.800.635.3811
Features and Operation
The Model 3430 Visual-Pager® is designed to
show up to four, 1- to 3-digit numbers at a time.
The display can rotate up to a total of 25 different
numbers that are entered in the B3611 Multi-
Number MultiPage Transmitter. The display has
2.5-inch tall digits viewable up to 80 feet and is
encased in an extruded-aluminum case. Unlimited
wireless displays may be incorporated, and each
display includes its own power adapter.
The Model 3620 Visual-Pager® is designed to
show up to six, 1- to 2-digit numbers at a time.
The display can rotate up to a total of 40 different
numbers that are entered in the B3611 Multi-
Number MultiPageTransmitter. The display has 2.5-inch tall digits viewable up to 80 feet and is encased in an
extruded-aluminum case. Unlimited wireless displays may be incorporated, and each display includes its own
power adapter.
Series 3600 Visual-Pager® Displays
Model 3530
Visual-Pager® Display
Model 3520
Visual-Pager® Display
Model 3620 and 3430
Visual-Pager® Displays
Features and Operation
The Model 3530 Visual-Pager® Display is designed to show and
rotate through one 3-digit number at a time. It has 5.5” tall digits
viewable from 125 feet, and is encased in an aluminum extrusion
case. Optional ceiling mounts are available in a single, double, or
triple cluster for easy mounting in the center of our around the
peripheral of a large retail area. Outdoor displays are also available
with high-bright LEDs for easy viewing.
The Model 3530 Visual-Pager® Display is designed to operate with
the Model B3611 Multi-Number MultiPage Transmitter. An unlimited
number of displays can be used with a single transmitter.
Features and Operation
The Model 3520 Visual-Pager® Display is designed to show and
rotate through one 2-digit number at a time. It has 5.5” tall digits
viewable from 125 feet, and is encased in an aluminum extrusion
case. Optional ceiling mounts are available in a single, double, or
triple cluster for easy mounting in the center of our around the
peripheral of a large retail area. Outdoor displays are also available
with high-bright LEDs for easy viewing.
The Model 3520 Visual-Pager® Display is designed to operate with
the Model B3611 Multi-Number MultiPage Transmitter. An unlimited
number of displays can be used with a single transmitter.

Series 3600 5
Microframe Corporation www.microframecorp.com 1.800.635.3811
Step 1:
With the power adapter unplugged, wire in the power adapter to the display.
To do this, simply place one wire from the adapter under one of the screwdown
terminals and the other wire under the other screwdown terminal. Carefully
tighten the screws. When you’ve done this, gently pull on the wires to ensure
they are properly installed. They should not come loose. Please refer to the
wiring diagram on the back of the display.
Step 2:
Attach the antenna. Then plug in the power adapter and check the
display for proper operation.
Step 3:
Hang the display. The display can be hung on the wall like a picture
frame on a nail or a screw from the keyhole in the back of the display.
OPERATION
If you purchased this display for use with a Model B3611 Multi-Number MultiPage Transmitter, you should be able to
simply plug in the display and then enter and delete numbers as specified in the “Transmitter Operation” section.
Step 1: Entering a Number
Enter the 2-digit number in the transmitter. The number will automatically appear on the Model B3611 Multi-Number
MultiPage Transmitter.
NOTE: If the display has reached its number capacity (20-40 numbers, depending on the display), it will not accept new
numbers.
Step 2: Deleting a Number
Press “CANCEL,” then enter the 2-digit number to delete. The number will be deleted from the transmitter and display.
DISPLAY OPTIONS
Auto Delete Setting
The display determines a number’s lifespan based on the auto-delete time. NOTE: If you have a Model B3611 Multi-
Number MultiPage Transmitter, use the transmitter’s auto-delete rather than the display’s auto-delete time. This option
allows the display to clear itself automatically if the transmitter is unplugged.
Blink Alert Settings
By default, each number will automatically start to blink after a predetermined display time. There are two types of blinks:
slow blink and fast blink. See programming instructions.
Application - The blink alerts are designed to convey a sense of urgency and to set time limits. As an example, perhaps
a restaurant is using the display. The kitchen enters Table “14” into the transmitter. The number “14” also shows on the
display, letting the server know the food for Table 14 is ready.
After three minutes (or the slow blink time), number 14 starts to blink slowly, meaning that Table 14’s food has been
sitting for a little while. After five minutes (or the fast blink time), number 14 will begin to blink rapidly, letting the wait staff
or expediter know that Table 14’s food needs to be picked up immediately.
Chime Setting
Determines the duration an external chime will sound. The chime is triggered the first time a new number is displayed.
See programming instructions.
Visual-Pager® Display Installation, Operation, and Options

Series 3600 6
Microframe Corporation www.microframecorp.com 1.800.635.3811
To change the programmable options on the display, you must transmit special codes to the display. These
special codes are described below.
How to Change a Programmable Option Using the Multi-Number MultiPage Transmitter
Press [*] to get to the Pager prompt. Type 9999 [ENTER]. At the Beep Type prompt press [ENTER]. At the
Message prompt, type the area to change as a two-digit number. Add a space using the [SETUP] key. Then
type the value to set as a two-digit number. Press [SEND] to set the display option.
As an example we will change the Display Rollover Time to 1 second per number. The message format will be
“01_01”. To begin, press [*] “9999” [ENTER]. Skip the Beep Type prompt by pressing [ENTER]. At the
Message prompt type in “01” [SETUP] “01” [SEND]. The transmitter will show it is sending the message. The
display will reflect the change by immediately changing the delay between numbers to one second.
The following user-programmable display options can be changed using the Multi-Number MultiPage
Transmitter:
0 –Number Source
1 –Rollover
2 –Auto-delete
3 –Chime
4 –Slow Flash
5 –Fast Flash
0 Setting the Display Number Source
Set area 00 to a value of 0000-9999. If the value is non-zero, the display will listen for that pager number and
show the message. Otherwise, it will show the pager number paged. The default is to listen for messages
(numbers) on pager 1500.
1 Setting the Display Rollover Time
Set area 01 to any value from 00-09. Each unit is 1 second. The default is 3 seconds (03). 00 means the
display will only show the last number received (no rollover).
2 Setting the Display Auto-Delete Time
Set area 02 to any value from 00-42. Each unit is 1 minute. The default is 42 minutes (42). 00 means the
auto-delete is disabled.
3 Setting the Display Chime Duration
Set area 03 to any value from 00-99. Each unit is 0.1 seconds. The default is 0.3 seconds (03). 00 means the
chime is disabled.
4 Setting the Display Slow-Flash Time
Set area 04 to any value from 00-99. Each unit is 10 seconds. The default is 90 seconds (09) –1.5 minutes.
00 disables the slow-flash function.
5 Setting the Display Fast-Flash Time
Set area 05 to any value from 00-99. Each unit is 10 seconds. The default is 180 seconds (18) –3 minutes.
00 disables the fast-flash function.
CLEARING THE DISPLAY
Setting area 99 to a value of 98 will clear all numbers from the Visual-Pager® display.
RESETTING DISPLAY TO FACTORY DEFAULTS
Setting area 99 to a value of 99 will reset all program areas to factory defaults.
Visual-Pager® Display Programming Instructions

Series 3600 7
Microframe Corporation www.microframecorp.com 1.800.635.3811
Area
Value
Default
Description
00
0000
Show pager # paged
00
0001-9999
1500
Show message of pager specified
01
00
Do not rotate the numbers
01
01-09
3
Rollover time (seconds)
02
00
Do not auto-delete
02
01-42
42
Auto-delete time (minutes)
03
00
Never chime
03
01-99
3
Chime duration (0.1 second interval)
04
00-99
9
Slow flash time (10 second interval)
00 disables
05
00-99
18
Fast flash time (10 second interval)
00 disables
99
98
Clear all numbers from display
99
99
N/A
Reset display to factory defaults
Visual-Pager® Display Programming Instructions continued...
SETTING THE DISPLAY OPTIONS
All display options are over-the-air programmable. By sending a properly formatted message, display settings
may be changed. The command channel for programming options is pager 9999. The message format is
generally AA_VV, where A is the area and V is the value. The one exception is area 00, where the format is
AA_VVVV.
Special instructions for the B3611: Press the [*] key to get to the pager prompt. Press the [SETUP] key to insert
a space in a message.
DISPLAY BASE ID
The Model 3620 Visual-Pager® display comes set with a base ID of 500,000. You should only have to
change the base ID if you have changed the default on the transmitter. Please contact Microframe first before
changing the default.
TO SET A NEW DISPLAY BASE ID:
Plug in the display. On the transmitter, page pager # 1 with a Beep Type of 2 and a Message of 7337. The
display will auto learn the transmitter identity and save it. It will signify successful programming by showing
horizontal bars for about five seconds. You should not have to repeat this step unless your paging system
changes. Note: The display will accept this command only within the first 30 seconds after turn-on.

Series 3600 8
Microframe Corporation www.microframecorp.com 1.800.635.3811
B3611 Multi-Number MultiPage Transmitter
Features and Specifications
Features
The Model B3611 Multi-Number MultiPage Transmitter is designed to accept numbers typed into the transmitter
and display them on a Visual-Pager® display. Depending on the mode, the transmitter can either show six 2-digit
numbers at a time or four 3-digit numbers.
Specifications
Desktop or Wall-Mountable
Compatible with Model 3520, 3530, 3620, and 3430 Visual-Pager® Displays.
Size: 9” x 7.5” footprint
Supplied with antenna, 12VDC power adapter, mounting wedge, and protective keypad cover.
Baud rate: 512, 1200
Range: ¼ to ½ mile typical indoors, 2 miles maximum

Series 3600 9
Microframe Corporation www.microframecorp.com 1.800.635.3811
Before permanent installation, we recommend that you test your entire system in one room on a table or floor.
This will be beneficial in troubleshooting should you have any problem during installation.
STEP 1: CONNECT THE ANTENNA
Connect the 90 degree antenna to the BNC connector located at the side of the transmitter. Maintain the antenna
in an upright position; this important for optimizing the range of the transmitter.
STEP 2: CONNECT THE POWER ADAPTER
Connect the supplied AC power adapter (see Figure 2). The transmitter will automatically come on. When the
transmitter is first powered up, the system will display the following screen for a few seconds:
Followed by:
The transmitter is now ready for operation.
PRECAUTIONS
Avoid placing the transmitter in the immediate vicinity of telephones, exchanges, or computer equipment. A few
feet can make a great difference in avoiding interference from the radio frequency generated by the transmitter.
The performance of your system will be effected by: foil backed wallboard, metal mesh, wire-reinforced glass,
metal sheeting, large mirrors, suspended ceilings, elevator shafts, etc. These can all reflect and thereby reduce
the signaling capability of the transmitter.
Transmitter Installation
IMPORTANT NOTE:
Use only the power adapter included with your system! The use of unapproved power adapters will invalidate
all warranty and service. We also recommend using a surge suppressor for protection. Power surges are not
covered under the warranty.
Caution: Transmitting without the antenna can damage the transmitter. Ensure that the antenna is connected
before powering the unit.

Series 3600 10
Microframe Corporation www.microframecorp.com 1.800.635.3811
BASIC OPERATION
This transmitter has its own built-in display so that you can view the numbers that are being entered and shown
on the Visual-Pager® display. Numbers that are entered will be added to both the transmitter and display. Once
the number capacity has been reached, the transmitter will not accept additional numbers.
Behavior
The transmitter can be configured for use with the 2-digit (3620 mode) or 3-digit (3430 mode) displays. The
operations described below are for the 2-digit mode, (3-digit operation is similar).
Automatic Entry
When number buttons 00 to 99 are pressed, they are automatically entered into the Visual-Pager® display and
also displayed on the transmitter. After you push the first number, such as “1,” the transmitter display shows
“Enter: 1” (see Figure 1). After you enter the second number “2,” the transmitter display shows “Enter: 12” for one
second and disappears. The number “12” will then appear on the Visual-Pager® display.
Selective Delete
To selectively delete a number, push [CANCEL] then the number you wish to delete from the Visual-Pager®
display. After you push the first number, such as “1,” the transmitter display shows “Cancel: 1.” After you enter
the second number “2,” the transmitter display shows “Cancel: 12” for one second and disappears (see Figure 2).
The number “12” will be removed from the transmitter screen and the Visual-Pager® display.
Transmitter Operation
LCD Display
Setup: Enter programmable options /
Space Key
Cancel: Cancel a number / Backspace
Enter: Enter a number /
Change programmable option
Send: Page / Save Options
Numeric Keypad
*: Enter pager prompt /
Scroll through options
Fig. 1
Fig. 2
#: Scroll through options
Antenna
(Required)

Series 3600 11
Microframe Corporation www.microframecorp.com 1.800.635.3811
To access these programming options for the transmitter, press [SETUP] on the keypad to enter programming
mode. You may scroll through all seven options by using the [*] or [#] buttons. Settings shown are factory
defaults.
Transmitter Programming Options

Series 3600 12
Microframe Corporation www.microframecorp.com 1.800.635.3811
Transmitter Programming Instructions
Transmitter Configuration
To access the programmable options, press the [SETUP] button at the Ready screen. Then press the [*] or [#]
buttons to move through the list of options. When you come to an option you would like to change, press
[ENTER]. Depending on the option, you can either press the [*] and [#] keys to change the value of the option, or
you can type in the desired number value. To return to the main options menu press [ENTER]. When finished
making changes, simply press the [SEND] key to save the changes or the [CANCEL] key to discard your
changes.
Option 1: Transmitter Rollover Time
This is the time that each number in the transmitter memory shows on the LCD screen before rotating to the next
number.
NOTE: The transmitter rollover time is completely independent of the Visual-Pager® display rollover
time.
Option 2: Transmitter Auto-Delete Time
The time that a number remains on the Visual-Pager® display before it is automatically deleted.
NOTE: The Visual-Pager® display has an independent auto-delete time which is set following the
instructions in the Visual-Pager® display section.
The factory default for the Visual-Pager® display delete time is 42 minutes. The reason for having an auto delete
time in the display, as well as the transmitter, is best understood by the following example. At the end of the day,
a user may unplug the transmitter to turn it off. If there are numbers being shown on the display when the
transmitter is turned off, the numbers will remain on the Visual-Pager® display until the display’s auto delete
removes them.
Option 3: Transmitter Entry Mode
Causes the transmitter to assume “Enter”or “Delete”when a number is typed in.
Option 4: Display ID - Main Remote Display Address
The specific display identity (0001-9998) to which the transmitter will be broadcasting. Each display may have a
different address.
Option 5: Transmitter Base ID
The common base number (* see note below) for all transmitters and Visual-Pager® displays in a system. This
can be used to keep multiple systems separate. Typically changed in multiples of 100,000, changing this option
will require reprogramming all displays in your system.
Option 6: Transmitter Baud Rate
The communications rate common to displays and pagers. At 512 baud rate, a transmission takes 2.1 seconds.
At 1200 baud rate, a transmission takes 0.9 seconds. Changing this option will require reprogramming all units in
your system.
Option 7: Behavior (2-Digit or 3-Digit)
Allows users to toggle the setting of the transmitter for use with 2-digit or 3-digit Visual-Pager® displays.
* = The Base ID of a system can be thought of as a neighborhood with house addresses corresponding to pager
numbers.

Series 3600 13
Microframe Corporation www.microframecorp.com 1.800.635.3811
Your 3600 Series Visual-Pager® display and Multi-Number MultiPage transmitter are designed to be reliable and
easy to use. This section answers frequently asked questions and contains information about the following topics:
•Error messages
•Hardware problems
•Programming problems
Problem
My Model 3611 Transmitter shows this when I turn it on:
Solution
1. The [0] button is being held down during turn on. This is a deliberate reset. Press [1] for “Yes” to reset factory
defaults.
2. One or more Option areas have become corrupted. It is recommended that you write down the correct
settings, reset defaults, and then make any changes to settings that are necessary. (See Programming Options.)
Please call Microframe if you need assistance at (800) 635-3811. We will be happy to help you.
Troubleshooting
Reset Defaults?
1=Yes 2=No

Series 3600 14
Microframe Corporation www.microframecorp.com 1.800.635.3811
The B3011 and B3611 transmitters are now supported by the same hardware platform. When you
order a B3011 or B3611, it should come pre-programmed to the correct type.
To change the transmitter type
•Unplug power
•While pressing “*”, 0, and “#”buttons, plug in power.
•At the password prompt, type “0320”[Enter].
•Select 1) 3500 or 2) 3600.
•Press [Enter] to save.
Appendix A: Changing the Transmitter Type

Series 3600 15
Microframe Corporation www.microframecorp.com 1.800.635.3811
Model 3500 Specifications
Visual-Pager® Display
1.5"
(3.8 cm)
9.1"
(23.1 cm)
9.8" 2-DIGIT
(24.9 cm) 13.2" 3-DIGIT
(33.5 cm) 16.8" 4-DIGIT
(42.7 cm)
P.O. Box 1700 , Broken Arrow, OK 74013
M odel 3500
Wireless
Remote Display
24 Volt AC
115TO 24VAC
WALL MOUNTED
(WIRE-IN)
TRANSFORMER
115VAC 3500\px\9700.ai
DATARECEIVE LED
PR OGRAM
Model 3500 Specifications
Voltage Input Requirements……………………
18V - 28V AC or DC
Character Height…………………………………
5.5 inches
Character Viewing Distance…………………….
125 feet indoors
Temperature Parameters……………………….
-20ºC to 40ºC (-4ºF to 158ºF)
Frequency……………………………………...…
457.575 Mhz
TX Baud Rate…………………………………….
512 or 1200
Environment………………………………………
Indoor use (Outdoor cases available)
Display Size
2-Digit
3-Digit
4-Digit
6-Digit
Power Requirements
2.9 watts
3.5 watts
4.6 watts
6.8 watts
Weight
2.5 lbs
3.2 lbs
3.9 lbs
5.25 lbs
Width "A" Dimension Inches
9.8"
13.2"
16.8”
24”
Width "A" Dimension Centimeters
24.9 cm
33.5 cm
42.7 cm
61.4 cm
Features
The Visual-Pager® displays are designed to work best with the
Microframe MultiPage System. The displays have two modes:
1) As a "Visual-Pager®," the display will store and rotate up to 20
numbers at a time. Numbers can be entered and deleted from the
display using the MultiPage Transmitter.
2) The display can also be used as a "Pager Confirmation System." In
this mode, the display shows the number of every vibrating pager that
has been paged.
Operation
Mode 1) Using the MultiPage Transmitter, simply type in a number and
press [ENTER] to send that number to the display. To delete a number
from the display, simply press [CANCEL] then type the number followed
by [ENTER].
Mode 2) The number of any pager that is paged shows on the display.
No operator intervention is required.

Series 3600 16
Microframe Corporation www.microframecorp.com 1.800.635.3811
Model 3430 Wireless Visual-Pager® Display Specifications
Operation
Works with Model 3611Transmitter
Baud Rate
1200
Power
24 VAC 1.2A supplied by adapter which
requires 115 AC @0.72 A
Range
½ Mile
Character Size
2.5” Tall
Number Capacity
Twenty-five 3-Digit Numbers (rotating)
Viewing Distance
80 Feet Indoors
Dimensions
16.8” x 9.1” x 1.5”
Weight
3.5 lbs
Features
The Model 3430 multi-number, wireless Visual-Pager® is designed
to show up to four, 1- to 3-digit numbers at a time. The display can
rotate up to a total of 25 different numbers that are entered in the
B3611 Multi-Number MultiPage Transmitter (sold separately). The
display has 2.5-inch tall digits viewable up to 80 feet and is enclosed
in an extruded-aluminum case. Each display includes its own power
adapter.
This is part of a fully expandable Visual-Paging® system that
accommodates multiple transmitters and displays.
Specification Sheet
Model 3430
Wireless Visual-Pager® Display
Related Products
Model 3611 MultiNumber
MultiPage Transmitter
Sold separately.
Model 3530 Visual-Pager® Display
Sold separately.

Series 3600 17
Microframe Corporation www.microframecorp.com 1.800.635.3811
Operation
Works with Model 3611Transmitter
Baud Rate
1200
Power
24 VAC 1.2A supplied by adapter which
requires 115 AC @0.72 A
Range
½ Mile
Character Size
2.5” Tall
Number Capacity
Thirty 2-Digit Numbers (rotating)
Viewing Distance
80 Feet Indoors
Dimensions
16.8” x 9.1” x 1.5”
Weight
3.5 lbs
Features
The Model 3620 multi-number, wireless Visual-Pager® is designed
to show up to six, 1- to 2-digit numbers at a time. The display can
rotate up to a total of 30 different numbers that are entered in the
B3611 Multi-Number MultiPage Transmitter (sold separately). The
display has 2.5-inch tall digits viewable up to 80 feet and is enclosed
in an extruded-aluminum case. Each display includes its own power
adapter.
This is part of a fully expandable Visual-Paging® system that
accommodates multiple transmitters and displays.
Specification Sheet
Model 3620
Wireless Visual-Pager® Display
Model 3611 MultiNumber
MultiPage Transmitter
Sold separately.
Model 3520 Visual-Pager® Display
Sold separately.
Related Products
Model 3620 Wireless Visual-Pager® Display Specifications

Series 3600 18
Microframe Corporation www.microframecorp.com 1.800.635.3811
MultiNumber Transmitter
Specifications
B3011 & B3611 Specifications
Voltage Input Requirements……………………
12VDC @ 5A (Power adapter requires 100-240V)
Paging Protocol………………………………….
POCSAG (512 or 1200 baud)
Frequency………………………………………..
457.575 Mhz
Max TX Power………….………………………..
2 Watts
FCC ID………………….…………………………
WDC-ISTATION-N. Complies with Part 90 of FCC Rules.
Coverage Area.…………………………………..
Typically 1/2 miles indoors. Max 2 miles.
Mounting……….………………………………….
Desk or Wall Mount
Dimensions……………………………………….
9.5”x 6”x 2.5”(Excludes antenna)
Max Numbers Shown on Display………………
20
Max Pagers in Re-Page Queue………………..
30
Features
This transmitter is designed to work out of the box with Multipage
displays and Slimline pagers.
Operation
Mode 1) Using the MultiPage Transmitter, simply type in a number and
press [ENTER] to send that number to the display. To delete a number
from the display, simply press [CANCEL] then type the number followed
by [ENTER].
Mode 2) The number of any pager that is paged shows on the display.
No operator intervention is required.
This manual suits for next models
4
Table of contents
Other Microframe Corporation Monitor manuals

Microframe Corporation
Microframe Corporation Visual-Pager 4500 Series User manual

Microframe Corporation
Microframe Corporation Visual-Pager 4600 Series User manual

Microframe Corporation
Microframe Corporation 4700 Series User manual

Microframe Corporation
Microframe Corporation 450A Series User manual

Microframe Corporation
Microframe Corporation Ethernet Visual-Pager 460A Series User manual

Microframe Corporation
Microframe Corporation 6500 Series User manual

Microframe Corporation
Microframe Corporation D5340 User manual