Microframe Corporation 2
604 South 12th Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com Series 4600
Limited Warranty Agreement
Your Microframe System is warranted against failure due to defects in workmanship or material for a period of one (1)
year from the date of purchase. Microframe Corporation will repair or replace any defective unit. Obvious abuse or
mishandling of the unit is NOT covered by this warranty.
Merchandise Return
If your Unit does not work satisfactorily, please give us a call. We may be able to clear up the problem by phone. If it
becomes necessary to return your Unit to the factory, please observe the following:
1. Call Microframe for an RMA number. This will authorize you to return the unit.
2. Place Unit in a sturdy box with sufficient packing material.
3. If requested, include the AC power adapter. It is not necessary to return the cable and connectors unless they are the
problem.
4. Return the system insured and prepaid. Microframe is not responsible for shipping damages and losses on returned
Units.
Warranty Service
For warranty service, please contact Microframe toll-free at 800-635-3811. One of our technicians will be glad to assist
you.
Assistance
For any product assistance or maintenance help, contact Microframe by either calling 800-635-3811 or e-mailing us at:
support@microframecorp.com.
Safety
Do not install substitute parts or perform any modification to the product without first contacting Microframe.
Disclaimer
We constantly strive to improve our products. Specifications are subject to change without notice.
Warning
All power adapters, line cords, and electrical equipment should be kept out of the reach of children and away from water.
(If you are installing cable in an air plenum area, such as a drop ceiling used for air return, you must use plenum-rated
cable. The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum
areas.)
Life Support Policy
Microframe's products are not authorized for use as components in life support devices or systems without the express
written approval of the President of Microframe Corporation. As used herein:
1. Life support devices or systems are defined as systems which support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a
significant injury to the user or any one depending on the system.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
FCC Notice (for wireless products only)
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.

Microframe Corporation 3
604 South 12th Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com Series 4600
Series 4600
Ethernet Visual-Pager® Display
Installation and Specification Guide
Table of Contents
1.0 Display Overview 4
1.1 Quick Install 4
1.2 Getting Started 4
2.0 Display Config Utility - Basic 5
2.1 Display Config Utility - Advanced 6
3.0 Installation / Operation / Options 7
4.0 Using the App 8
5.0 General Troubleshooting Chart 9
Specifications 10

Microframe Corporation 4
604 South 12th Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com Series 4600
The Ethernet Visual-Pager® Display is a wired version of our D4500 WiFi displays. This eliminates any WiFi
connectivity or setup issues. Once this display is connected to your LAN network, it can be controlled from
any computer or wireless device on the network. These devices are controlled by the same Visual Paging
apps used by our WiFi displays.
We recommend setting up your unit and testing it before permanent installation.
Ethernet Displays
1) Use an Ethernet cable to plug the display into your LAN network
2) Attach the power cable to the terminals on the back of the display
3) Plug in the power adapter
4) When the middle status light (bottom right corner) goes solid, then the display is online and ready for use.
Download Apps
Download one of the following apps:
Android: Google Play Store search “Microframe WiFi Visual Pager”
iOS: Apple Store search “Microframe WiFi Visual Pager”
Kindle: Amazon App Store search “Microframe WiFi Visual Pager”
MAC: https://www.microframecorp.com/download-software -> D4500 Paging and Configuration Software for OS X
PC: https://www.microframecorp.com/download-software -> D4500 Paging and Configuration Software for Windows
Basic Configuration
Mobile App: Use the “Setup” mode under “Display Settings”. Set the display name and pin, then save settings.
MAC/PC App: Click “Configure”.
Advanced Configuration
To set a static IP address, download the Ethernet config tool here:
MAC\PC: https://www.microframecorp.com/download-software -> D4600 Discovery and Settings.
The Java “JAR” file inside the zip will run on both platforms.
You may change the following options: IP, Gateway, Subnet, Use DHCP.
Caution: do not change other options, as it will cause the Ethernet module to stop working. If this happens, you can reset
the display to factory defaults by holding the button on the back of the display.
You can also change the Display Name and Pin Number using the MAC/PC app. Click “Configure”, then “Advanced”.
1.1 Quick Install
1.0 Display Overview
1.2 Getting Started

Microframe Corporation 5
604 South 12th Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com Series 4600
Setup
1. Connect display to computer
2. Open Config Utility
3. Select network from list
4. Type in network password
5. <Optional> Set Device Name
6. <Recommended> Set App Pin
7. Click [SAVE]. The button will
turn orange while connecting.
8. The button will turn red if
failed, or green if success.
9. You may now disconnect the
display from the computer and
mount it on a wall.
Summary
This config utility is designed for WiFi displays, but it is also useful to set the Device Name and App Pin.
Details
The only network that will show up for Ethernet displays is “Ethernet”.
The SSID must be selected, but is not used. Both the SSID and Password are ignored.
The Device Name is used in the app.
The App Pin must match the pin number set on your mobile app. It is strongly recommended that you change
this from the default of "0000" to prevent unauthorized users from accessing the display.
Re-enabling setup mode
To place the display back in setup mode, press and hold the mode button. The display will start counting down
"r5", r4", etc. When it gets to "RST", release the button. The display will reset to factory defaults and reboot
automatically.
2.0 Wi-Fi Display Config Utility - Basic

Microframe Corporation 6
604 South 12th Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com Series 4600
Configuration Utility
Setup
1) Power Disp
2) Open Prog
3) Find
4) Read All
5) Scan
6) Select AP
7) Password
8) [Connect]
Summary
The Advanced version of the Config Utility allows for configuration of all Wi-Fi settings.
For Ethernet displays the only options that apply are the device NAME and PIN.
Details
[Serial] – Shows the currently connected serial port.
[Connected/Disconnected] - Automatically scans for devices and prints results to the log. It will select the
device found last.
[Read All] - Reads back settings for all three panels of the utility. Optionally you can read/write individual
panels using the respective buttons.
[Scan] - Loads list of access points (AP).
[Connect] - Used to save settings if specific options are changed. Generally this will turn green if a save is
required.
[AP] – Always returns “Ethernet” for Ethernet displays.
[NAME] - The name of the device. This is used in the app, and can also be typed into a browser, provided
NETBIOS name lookups are working on your network. i.e. "DISPLAY1/" (note the slash).
[PIN] - The PIN used by the app to connect to this display.
[Basic] - Switch back to basic mode.
2.1 Wi-Fi Display Config Utility - Advanced

Microframe Corporation 7
604 South 12th Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com Series 4600
Mounting the Display
This product comes with tilt-mount brackets. To mount the
display, connect the 24-volt AC power adapter wire to the back
of the display. Plug in the Ethernet cable and make sure it
won’t get pinched. Use two drywall screws per side to mount
the display to the wall. Plug the adapter into the wall and you
are ready to go.
Operation
The Visual-Pager® Display’s primary operation is to display
numbers that are sent to it via the computer or mobile apps.
Sending Numbers to Visual-Pager® Displays from the Smart Phone App (also see Section 5.1):
• To send a number to a display from the app, simply type the number that you want to display, i.e.
“1234” and then tap [Add].
• To delete a number from the display from the app, tap the number to delete and tap [Delete].
• To clear all displays connected to the network tap [Clear All].
Sending Numbers to Visual-Pager® Displays from the computer app:
• To send a number to a display using the app, simply type the number that you want to display, i.e.
“1234” and then click [Send].
• To delete a number from the display using the app, click on the number to delete and click [Delete].
• To clear all displays connected to the network click [Delete All].
Programmable Configurations
Roll-Over Time Setting
The Roll-Over Time is the time each number in the display’s memory is shown before changing to the next number.
This time can be set from 1 to 9 seconds.
Auto Delete Setting
The display can be set to automatically delete a number from its memory after a preset time from 0 to 42
minutes. When set to 0 the display will not auto-delete.
Chime Volume Setting
The chime volume can be set from 0 to 9. Setting to 0 will turn off the chime, while 9 is the loudest setting.
Chime Cycle Setting
The chime can be set to Off, a Single Chime, or a Double Chime. Setting this option to 0 turns off the chime.
Setting this option to 1 will make the display chime once every time it receives a new number. Setting this
option to 2 will make the display chime twice every time it receives a new number.
3.0 Installation / Operation / Options

Microframe Corporation 8
604 South 12th Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com Series 4600
Visual Paging Page
On this page you can add and delete numbers to all connected and active displays. To add a number, tap the
text box labeled "Number to Display". This will activate your device’s keyboard. Type the number you would
like to show on the display, and tap [ADD]. To delete numbers from the display, tap on the number in the list
and then tap [Delete]. To clear all numbers on all the displays across the network you can tap [Clear All].
Hymn Mode Page
On this page you can add a list of numbers and then show them one by one. To add a number tap the text
box labeled "Number to Add". This will activate your device’s keyboard. Type the number you would like to
add to the list, and tap [ADD]. To delete numbers from the list, tap on the number in the list and then tap
[Delete]. To clear all numbers from the list, tap [Clear All]. Once you have your list entered tap [Start]. The first
number in the list will show. To show the next hymn tap [Next]. The display will clear the number showing, and
then show the next number in the list.
Displays Page
This page contains a list of all the Visual-Pager® Displays that the app finds on the network. This list shows
the Name of the device and the IP address that is assigned to the display. To edit a display, tap the display in
the list that you wish to edit. The Display Settings page allows you to do the following:
Active: When a display is active it will receive from this app. If you wish not to send to a certain display you
can uncheck this box. The display will no longer receive numbers from this app.
Pin: The pin number is specified during the initial setup. To communicate with the display, you will need to
type in the correct Pin number here. The default pin is 0000.
Rollover: The Roll-Over time is the time each number in the display memory is shown before changing to the
next number. This time can be set from 1 to 9 seconds.
Auto Delete: The display can be set to automatically delete a number from its memory after a preset time of
from 0 to 42 minutes. When set to 0 the display will not auto-delete.
Chime Volume: This option can be set by dragging the volume bar.
Chime Cycle: The drop down will allow you to set how many times you would like the chime to sound when
sending a number. Chime off, Single Chime, or Double Chime.
4.0 Using the App

Microframe Corporation 9
604 South 12th Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com Series 4600
6.1 Can’t access the display setup mode.
1. Reset display to factory defaults by pressing the button on the back of the display for 5
seconds.
2. Make sure that both the display and your device are on the same network.
6.2 No Displays found on the network.
1. Be sure that your device is connected to the same network as the displays.
2. Does your network allow communication between devices? Guest networks often have
“client partitioning” enabled, which prevents devices from seeing each other.
3. The display has one solid light and one blinking light. If both lights are blinking the
display is not connected to the network. Check that the network cable is plugged in
properly. Reboot the display by momentarily unplugging power.
4. Check that the display Ethernet settings are correct by using the Wiznet config tool.
6.3 Numbers are not showing on displays.
1. Pin number in the app must be the same as the pin number you used when setting up
the display.
2. Display is no longer on the network. Are the power and network cables plugged in?
5.0 General Troubleshooting Chart

Features
The 4600 is an Ethernet connected numeric display
intended for Visual-Paging®. The display will store and
rotate up to 20 numbers at a time. Codes can be entered
and deleted from the display using our apps. Apps are
available for Android, Apple, Kindle, MAC, and PC devices.
Box Contents
(1) D4600 Display; Tilt mount assembly
(1) 24VAC power adapter w/ 20ft of wire
(1) Manual, (1) Microframe Screwdriver
(1) Configuration CD, (1) USB A to B cable
Model 4600 Specifications
Voltage Input Requirements……………………
14-24 VAC, 16-28VDC
Character Height…………………………………
5.5 inches
Character Viewing Distance…………………….
125 feet
Temperature Parameters……………………….
-20ºC to 40ºC (-4ºF to 158ºF)
Casing…………………………………………….
Aluminum extrusion
Color……………………………………………….
Black frame with dark red acrylic faceplate
Environment………………………………………
Indoor use
Ethernet……………………………………………
10/100Mbps
Display Size
2-Digit
3-Digit
4-Digit
6-Digit
Power Requirements
3.4 watts
4 watts
5.1 watts
7.3 watts
Display Weight, w/o adapter
2.8 lbs
(1.1 kg)
3.5 lbs
(1.4 kg)
4.2 lbs
(1.6 kg)
5.6 lbs
(2.4 kg)
Width "A" Dimension
9.8"
(24.9 cm)
13.2"
(33.5 cm)
16.8"
(42.7 cm)
24"
(61.4 cm)
Model 4600 Specifications
Numeric Display
Table of contents
Other Microframe Corporation Monitor manuals

Microframe Corporation
Microframe Corporation Visual-Pager 4500 Series User manual

Microframe Corporation
Microframe Corporation 4700 Series User manual

Microframe Corporation
Microframe Corporation Ethernet Visual-Pager 460A Series User manual

Microframe Corporation
Microframe Corporation 450A Series User manual

Microframe Corporation
Microframe Corporation D5340 User manual

Microframe Corporation
Microframe Corporation 6500 Series User manual

Microframe Corporation
Microframe Corporation Visual-Pager 3600 Series User manual